0000000000125154

AUTHOR

Maryam Mousavi

showing 6 related works from this author

Tear Film Surface Quality in Modern Daily Disposable Contact Lens Wear

2021

Objectives As reported previously, tear film surface quality (TFSQ) should be considered in contact lens (CL) fitting. This study followed noninvasive keratograph tear film break-up time (NIKBUT) in CL wearers for 12 months to validate its clinical utility in predicting CL performance. Methods Fifty-five subjects (M/F=17/38) aged 26±4 years were prescribed silicone hydrogel or hydrogel CLs. The study included baseline measurements without CLs; 2 visits for CL fitting and control; follow-up after 3, 6, and 12 months of CL wear; and postwear visit without CLs. Ocular Surface Disease Index (OSDI), 8-Item Contact Lens Dry Eye Questionnaire (CLDEQ-8), first and mean NIKBUT (F/M-NIKBUT), fluoresc…

medicine.medical_specialtyCorneal stainingbusiness.industrySilicone hydrogelContact Lenses HydrophilicEyeContact lensOphthalmologyCLs upper limitsTearsOphthalmologyHumansTearsMedicineDry Eye SyndromesDaily disposableOcular Surface Disease IndexbusinessOcular surfaceVision OcularEye & Contact Lens: Science & Clinical Practice
researchProduct

A 12-month Prospective Study of Tear Osmolarity in Contact Lens Wearers Refitted with Daily Disposable Soft Contact Lenses

2020

SIGNIFICANCE Tear osmolarity has been reported as one of the best diagnostic tests for dry eye disease and its management. Contact lens wear is thought to influence tear homeostasis. Understanding how regular wear of contact lenses and their type affect tear osmolarity is important. PURPOSE The purpose of this study was to assess changes in tear osmolarity and ocular symptoms over a period of 12 months following refitting contact lens wearers with daily disposable contact lenses. METHODS Fifty subjects aged (mean ± SD) 26 ± 4 years were refitted with either silicone-hydrogel (delefilcon A, SiHy, n = 34) or hydrogel (omafilcon A, Hy, n = 16) daily disposable soft contact lenses. Study includ…

AdultMalemedicine.medical_specialtyLower scorelaw.inventionYoung Adult03 medical and health sciences0302 clinical medicinelawProsthesis FittingSurveys and QuestionnairesOphthalmologymedicineHumansOcular Surface Disease IndexProspective StudiesDisposable EquipmentProspective cohort studybusiness.industryOsmolar ConcentrationHydrogelsContact Lenses HydrophilicTear osmolarityeye diseasesLens (optics)Contact lensOphthalmologyTearsTime course030221 ophthalmology & optometryDry Eye SyndromesFemaleDaily disposablesense organsbusiness030217 neurology & neurosurgeryOptometryOptometry and Vision Science
researchProduct

Evaluating tear clearance rate with optical coherence tomography

2017

Purpose: To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality. Methods: TCR was classified as the percentage decrease of the inferior tear meniscus height 30s after instillation of 5uL 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean +/- standard deviation) 25.5 +/- 4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR …

AdultMalemedicine.medical_specialtymedicine.medical_treatmentDry Eye SyndromesFOS: Physical sciencesLacrimal apparatusSlit Lamp Microscopy03 medical and health sciencesYoung Adult0302 clinical medicineOptical coherence tomographyOphthalmologyTear meniscus heightmedicineHumansOcular Surface Disease IndexSalineFluorescent Dyesmedicine.diagnostic_testbusiness.industryLacrimal ApparatusGeneral MedicinePhysics - Medical Physicseye diseasesSurgeryOphthalmologyTear meniscusmedicine.anatomical_structureTears030221 ophthalmology & optometryTearsDry Eye SyndromesFemaleFluoresceinMedical Physics (physics.med-ph)sense organsbusiness030217 neurology & neurosurgeryTomography Optical CoherenceOptometryOptics (physics.optics)Physics - Optics
researchProduct

The impact of daily disposable soft contact lens wear on tear film surface quality over a three month period

2017

Contact lensOphthalmologymedicine.medical_specialtybusiness.industrymedicineDentistryDaily disposableGeneral MedicinebusinessSurgeryActa Ophthalmologica
researchProduct

The utility of measuring tear film break-up time for prescribing contact lenses.

2017

Abstract Purpose To evaluate the clinical value of non-invasive keratograph tear film breakup time (NIKBUT) in the assessment of pre-corneal and pre-lens tear film quality for prescribing contact lenses (CLs). Methods Forty-six subjects aged 25.5 ± 4.3 (mean ± standard deviation) years were recruited. Visual acuity (VA), anterior eye health checks and NIKBUT were evaluated. On the following day, subjects were fitted with a daily Silicon Hydrogel (SiHy) CL in one eye and a Hydrogel (Hy) CL in the other. After four hours one material for both eyes was chosen based on a qualitative analysis which included VA, CL fitting and comfort. Information about the first and the mean NIKBUT was then cont…

0301 basic medicineAdultMalemedicine.medical_specialtyVisual acuityVisual Acuitylaw.invention03 medical and health sciencesYoung Adult0302 clinical medicineCLs upper limitslawOphthalmologyEye healthmedicineHumansmedicine.diagnostic_testBlinkingbusiness.industryCorneal TopographyQuality measurementGeneral MedicineTear film break-up timeCorneal topographyContact Lenses Hydrophiliceye diseasesLens (optics)Ophthalmology030104 developmental biologyPrescriptionsTears030221 ophthalmology & optometryTearsFemalemedicine.symptombusinessOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

The impact of long-term wear of modern daily disposable contact lenses on ocular physiology

2019

Numerosos estudios han mostrado que las lentes de contacto disrumpen la película lagrimal debido a la creación de una capa pre y post lente produciendo una alteración de sus funciones fisiológicas. Esto conduce a cambio en la composición de la película lagrimal: lípidos, proteínas, mucina y electrolitos. La película lagrimal preocular varía constantemente tras el parpadeo habiendo una primera fase de formación, inmediatamente tras el parpadeo, una fase más o menos estable entre parpadeos, y una última fase de adelgazamiento y posterior desestabilización de la película lagrimal que puede desencadenar la ruptura de la película lagrimal en sujetos con síndrome de ojo seco o cuando el ojo perma…

:FÍSICA [UNESCO]UNESCO::FÍSICAoptometríabioopticaórganos sensoriales
researchProduct