The utility of measuring tear film break-up time for prescribing contact lenses.
D. Robert IskanderDanilo Andrade De JesusDanilo Andrade De JesusDorota H. Szczesna-iskanderMaryam MousaviIzabela K GaraszczukIzabela K. Garaszczuksubject
0301 basic medicineAdultMalemedicine.medical_specialtyVisual acuityVisual Acuitylaw.invention03 medical and health sciencesYoung Adult0302 clinical medicineCLs upper limitslawOphthalmologyEye healthmedicineHumansmedicine.diagnostic_testBlinkingbusiness.industryCorneal TopographyQuality measurementGeneral MedicineTear film break-up timeCorneal topographyContact Lenses Hydrophiliceye diseasesLens (optics)Ophthalmology030104 developmental biologyPrescriptionsTears030221 ophthalmology & optometryTearsFemalemedicine.symptombusinessOptometrydescription
Abstract Purpose To evaluate the clinical value of non-invasive keratograph tear film breakup time (NIKBUT) in the assessment of pre-corneal and pre-lens tear film quality for prescribing contact lenses (CLs). Methods Forty-six subjects aged 25.5 ± 4.3 (mean ± standard deviation) years were recruited. Visual acuity (VA), anterior eye health checks and NIKBUT were evaluated. On the following day, subjects were fitted with a daily Silicon Hydrogel (SiHy) CL in one eye and a Hydrogel (Hy) CL in the other. After four hours one material for both eyes was chosen based on a qualitative analysis which included VA, CL fitting and comfort. Information about the first and the mean NIKBUT was then contrasted against the prescription decision. Results Thirty-four subjects were fitted with SiHy and twelve with Hy CL. No statistically significant differences were found for both NIKBUT parameters between left and right eye at baseline (p = 0.38 and p = 0.50, respectively) and post four hours of CL wear (p = 0.61 and p = 0.06). The chosen lens did not always correspond to longer NIKBUT. In 39.1% and 34.8% of cases (i.e., 18 and 16 out of 46), there was a match between prescription decision and the first and the mean NIKBUT results, respectively. Conclusions Although there is no evidence whether tear film surface quality measurement has a superior diagnostic values compared to other traditional clinical measures used in practice, NIKBUT measurements have provided additional information that could be of interest during CL fit.
year | journal | country | edition | language |
---|---|---|---|---|
2017-06-29 | Contact lensanterior eye : the journal of the British Contact Lens Association |