0000000000129332
AUTHOR
Jana Lill
Bilobectomy for massive hemoptysis after bilateral lung transplantation
AbstractJ Thorac Cardiovasc Surg 2001;121:1194-5
SPLIT-LUNG VOLUMETRY IN PATIENTS AFTER SINGLE-LUNG TRANSPLANTATION USING 3HELIUM-MRI
Volumetry of Ventilated Airspaces by 3He MRI
To develop a validated post-processing routine for volumetry of the ventilated airspaces by 3He MRI.3Helium MRI and pulmonary function tests were performed in seven healthy volunteers. After segmentation of ventilated airspaces, their volumes were calculated. Functional residual capacity (FRC) was used as a reference. For comparison of absolute volumes, correction factors were evaluated.Mean lung volume (+/- standard deviation) calculated from 3He MRI was 4,082 +/- 908 mL and mean FRC was 3,696 +/- 1166 mL, with a mean difference of 386 mL (r = 0.88). After correction for the relative pulmonary air content (factor 0.82), posture (0.72), and the individual tidal volume, 3He MRI volume was 3,…
MRI in lung transplant recipients using hyperpolarized 3He: comparison with CT.
PURPOSE To elucidate the ability of 3He-MRI to detect ventilation defects in lung transplant recipients, 3He-MRI was compared to CT for concordance. MATERIALS AND METHODS We examined 14 lung recipients using 3He-MRI on a 1.5 T MR scanner. CT served as a reference method. Up to four representative ventilation defects were defined for each lung on 3He-MRI and compared to corresponding areas on CT. RESULTS Altogether, 59 representative ventilation defects were defined on 3He-MRI. Plausible CT correlates were found for 29 ventilation defects; less plausible CT correlates were found for eight defects. In 22 defects (37%) no corresponding CT changes were detected. CT demonstrated correlates for v…
Diagnostik der trachealen Instabilität: Spiral-CT in Inspiration und Exspiration und respiratorische cine-CT∗
ry Spiral CT and Cine CT. Purpose: In tracheo- and broncho-malacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results : In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the …
Akute oder chronische Transplantat-Abstoßung? - HRCT des Thorax bei Patienten nach Lungentransplantation
Purpose: Aim of the study was to evaluate the postoperative changes in patients with single (SLTX) or double lung transplantation (DLTX) with HRCT and to correlate those findings with the clinical diagnosis. Material and methods: 29 patients with SLTX (n = 14) or DLTX (n=15) were observed for more than 6 years after transplantation by HRCT (n =82). CT examinations were performed in inspiration and expiration (n=70) with a slice thickness of 1 mm and a feed of 10 mm. The image material was evaluated by 2 experienced radiologists in consensus. Criteria for acute rejection at HRCT were: ground glass opacities and focal air trapping in expiration. Criteria for chronic transplant rejection were:…
3He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes
MRI with hyperpolarized helium-3 (3He) provides high-resolution imaging of ventilated airspaces. The first aim of this 3He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired 3He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/α = 11 ms/4.2 ms/<10°). Known amounts of 3He were inhaled from a microprocessor-controlled delivery device…