0000000000130700

AUTHOR

R. Heinke

Large Shape Staggering in Neutron-Deficient Bi Isotopes

research product

First demonstration of Doppler-free 2-photon in-source laser spectroscopy at the ISOLDE-RILIS

Abstract Collinear Doppler-free 2-photon resonance ionization has been applied inside a hot cavity laser ion source environment at CERN-ISOLDE. An injection-seeded Ti:sapphire ring laser was used to generate light pulses with a Fourier-limited linewidth for high-resolution spectroscopy. Using a molybdenum foil as a reflective surface positioned at the end of the target transfer line, rubidium was successfully ionized inside the hot cavity. The results are presented alongside previously obtained data from measurements performed at the RISIKO mass separator at Mainz University, where collinear and perpendicular ionization geometries were tested inside an RFQ ion guide. This work is a pre-curs…

research product

Hyperfine structure study of Tc97,98,99 in a new laser ion source for high-resolution laser spectroscopy

Using a novel concept for efficient laser spectroscopy, we investigated the hyperfine splittings of three different atomic transitions in the long-lived isotopes $^{97\ensuremath{-}99}\mathrm{Tc}$. Despite the refractory character of the element technetium, sample sizes as low as ${10}^{11}$ atoms were sufficient to achieve excellent signal-to-noise ratios at a spectroscopic linewidth of less than 100 MHz. The obtained spectra were analyzed in detail, which results in a very good consistency for the extracted hyperfine parameters from the different transitions. The presented measurements provide the first hyperfine structure data for the isotopes $^{97,98}\mathrm{Tc}$ from which, in combina…

research product

Production of neptunium and plutonium nuclides from uranium carbide using 1.4-GeV protons

Accelerator-based techniques are one of the leading ways to produce radioactive nuclei. In this work, the Isotope Separation On-Line method was employed at the CERN-ISOLDE facility to produce neptunium and plutonium from a uranium carbide target material using 1.4-GeV protons. Neptunium and plutonium were laser-ionized and extracted as 30-keV ion beams. A Multi-Reflection Time-of-Flight mass spectrometer was used for ion identification by means of time-of-flight measurements as well as for isobaric separation. Isotope shifts were investigated for the 395.6-nm ground state transition in $^{236,237,239}$Np and the 413.4-nm ground state transition in $^{236,239,240}$Pu. Rates of $^{235-241}$Np…

research product

Atom beam emersion from hot cavity laser ion sources

Abstract Ion sources exploiting laser resonance ionization offer efficient and element-selective radioactive ion beam production at the leading isotope separation on-line facilities worldwide. Most commonly, laser resonance ionization takes place inside a resistively heated atomizer tube directly coupled to the production target, where the element of interest is evaporated and provided as atomic vapor. While naturally the majority of atoms is ionized inside this hot cavity, a fraction of the neutrals effuses towards the high voltage beam extraction system of the subsequent mass separator. We report on several systematic investigations on this phenomenon regarding its significance and implic…

research product

Radium ionization scheme development: The first observed autoionizing states and optical pumping effects in the hot cavity environment

© 2018 The Authors This paper reports on resonance ionization scheme development for the production of exotic radium ion beams with the Resonance Ionization Laser Ion Source (RILIS) of the CERN-ISOLDE radioactive ion beam facility. During the study, autoionizing states of atomic radium were observed for the first time. Three ionization schemes were identified, originating from the 7s2 1S0 atomic ground state. The optimal of the identified ionization schemes involves five atomic transitions, four of which are induced by three resonantly tuned lasers. This is the first hot cavity RILIS ionization scheme to employ optical pumping effects. The details of the spectroscopic studies are described …

research product

Towards high-resolution laser ionization spectroscopy of the heaviest elements in supersonic gas jet expansion

Resonant laser ionization and spectroscopy are widely used techniques at radioactive ion beam facilities to produce pure beams of exotic nuclei and measure the shape, size, spin and electromagnetic multipole moments of these nuclei. However, in such measurements it is difficult to combine a high efficiency with a high spectral resolution. Here we demonstrate the on-line application of atomic laser ionization spectroscopy in a supersonic gas jet, a technique suited for high-precision studies of the ground- and isomeric-state properties of nuclei located at the extremes of stability. The technique is characterized in a measurement on actinium isotopes around the N=126 neutron shell closure. A…

research product

Laser resonance ionization spectroscopy on lutetium for the MEDICIS project

The MEDICIS-PROMED Innovative Training Network under the Horizon 2020 EU program aims to establish a network of early stage researchers, involving scientific exchange and active cooperation between leading European research institutions, universities, hospitals, and industry. Primary scientific goal is the purpose of providing and testing novel radioisotopes for nuclear medical imaging and radionuclide therapy. Within a closely linked project at CERN, a dedicated electromagnetic mass separator system is presently under installation for production of innovative radiopharmaceutical isotopes at the new CERN-MEDICIS laboratory, directly adjacent to the existing CERN-ISOLDE radioactive ion beam …

research product

Developments towards in-gas-jet laser spectroscopy studies of actinium isotopes at LISOL

To study exotic nuclides at the borders of stability with laser ionization and spectroscopy techniques, highest efficiencies in combination with a high spectral resolution are required. These usually opposing requirements are reconciled by applying the in-gas-laser ionization and spectroscopy (IGLIS) technique in the supersonic gas jet produced by a de Laval nozzle installed at the exit of the stopping gas cell. Carrying out laser ionization in the low-temperature and low density supersonic gas jet eliminates pressure broadening, which will significantly improve the spectral resolution. This article presents the required modifications at the Leuven Isotope Separator On-Line (LISOL) facility…

research product

In-source and in-trap formation of molecular ions in the actinide mass range at CERN-ISOLDE

The use of radioactive molecules for fundamental physics research is a developing interdisciplinary field limited dominantly by their scarce availability. In this work, radioactive molecular ion beams containing actinide nuclei extracted from uranium carbide targets are produced via the Isotope Separation On-Line technique at the CERN-ISOLDE facility. Two methods of molecular beam production are studied: extraction of molecular ion beams from the ion source, and formation of molecular ions from the mass-separated ion beam in a gas-filled radio-frequency quadrupole ion trap. Ion currents of U$^+$, UO$_{1-3}^+$, UC$_{1-3}^+$, UF$_{1-4}^+$, UF$_{1,2}$O$_{1,2}^+$ are reported. Metastable tantal…

research product

Laser photodetachment of radioactive $^{128}$I$^−$

International audience; The first experimental investigation of the electron affinity (EA) of a radioactive isotope has been conducted at the CERN-ISOLDE radioactive ion beam facility. The EA of the radioactive iodine isotope (128)I (t (1/2) = 25 min) was determined to be 3.059 052(38) eV. The experiment was conducted using the newly developed Gothenburg ANion Detector for Affinity measurements by Laser PHotodetachment (GANDALPH) apparatus, connected to a CERN-ISOLDE experimental beamline. (128)I was produced in fission induced by 1.4 GeV protons striking a thorium/tantalum foil target and then extracted as singly charged negative ions at a beam energy of 20 keV. Laser photodetachment of th…

research product

In-gas laser ionization and spectroscopy of actinium isotopes near the N=126 closed shell

The in-gas laser ionization and spectroscopy (IGLIS) techniquewas applied on the $^{212–215}$Ac isotopes, produced at the Leuven Isotope Separator On-Line (LISOL) facility by using the in-gas-cell and the in-gas-jet methods. The first application under on-line conditions of the in-gas-jet laser spectroscopy method showed a superior performance in terms of selectivity, spectral resolution, and efficiency in comparison with the in-gas-cell method. Following the analysis of both experiments, the magnetic-dipole moments for the $^{212–215}$Ac isotopes, electric-quadrupole moments and nuclear spins for the $^{214,215}$Ac isotopes are presented and discussed. A good agreement is obtained with lar…

research product

High-resolution laser resonance ionization spectroscopy of $^{143-147}$Pm

The European physical journal / A 56(2), 69 (2020). doi:10.1140/epja/s10050-020-00061-8

research product

Large shape staggering in neutron-deficient Bi isotopes

The changes in the mean-square charge radius (relative to 209Bi), magnetic dipole, and electric quadrupole moments of 187,188,189,191Bi were measured using the in-source resonance-ionization spectroscopy technique at ISOLDE (CERN). A large staggering in radii was found in 187,188,189Big, manifested by a sharp radius increase for the ground state of 188Bi relative to the neighboring 187,189Big. A large isomer shift was also observed for 188Bim. Both effects happen at the same neutron number, N=105, where the shape staggering and a similar isomer shift were observed in the mercury isotopes. Experimental results are reproduced by mean-field calculations where the ground or isomeric states were…

research product

Nuclear moments of indium isotopes reveal abrupt change at magic number 82

In spite of the high-density and strongly correlated nature of the atomic nucleus, experimental and theoretical evidence suggests that around particular 'magic' numbers of nucleons, nuclear properties are governed by a single unpaired nucleon1,2. A microscopic understanding of the extent of this behaviour and its evolution in neutron-rich nuclei remains an open question in nuclear physics3-5. The indium isotopes are considered a textbook example of this phenomenon6, in which the constancy of their electromagnetic properties indicated that a single unpaired proton hole can provide the identity of a complex many-nucleon system6,7. Here we present precision laser spectroscopy measurements perf…

research product

Measurement of the laser resonance ionization efficiency for lutetium

Abstract The development of a highly efficient resonance ionization scheme for lutetium is presented. A laser ion source, based on the all-solid-state Titanium:sapphire laser system, was used at the 30 keV RISIKO off-line mass separator to characterize different possible optical excitation schemes in respect to their ionization efficiency. The developed laser resonance ionization scheme can be directly applied to the use at radioactive ion beam facilities, e. g. at the CERN-MEDICIS facility, for large-scale production of medical radioisotopes.

research product