0000000000132824
AUTHOR
Valentin Fedosseev
Continuously tunable diamond Raman laser for resonance ionization experiments at CERN
We demonstrate a highly efficient, continuously tunable, diamond Raman laser operating in the blue region of the spectrum. The linewidth and tunability characteristics of a frequency-doubled Ti:Sapphire laser were transferred directly to the Stokes output, offering great potential for spectroscopic applications using an all-solid-state platform.
Beta-decay measurements of neutron-rich thallium, lead, and bismuth by means of resonant laser ionisation
Abstract Neutron-rich thallium, lead, and bismuth isotopes were investigated at the ISOLDE facility. After mass separation and resonant laser ionisation of the produced activity, new spectroscopic data were obtained for 215,218 Bi and 215 Pb. An attempt to reach heavy thallium had to be abandoned because of a strong francium component in the beam that gave rise to a neutron background through (α,n) reactions on the aluminium walls of the experimental chamber.
Continuously tunable diamond Raman laser for resonance laser ionization.
We demonstrate a highly efficient, tunable, ∼5 GHz line- width diamond Raman laser operating at 479 nm. The diamond laser was pumped by a wavelength-tunable intra- cavity frequency-doubled titanium sapphire (Ti:Sapphire) laser operating at around 450 nm, at a repetition rate of 10 kHz with a pulse duration of 50 ns. The Raman reso- nator produced a continuously tunable output with high stability, high conversion efficiency (28%), and beam quality (M$^{2}$ <1.2). We also demonstrate that the linewidth and tunability of the pump laser is directly transferred to the Stokes output. Our results show that diamond Raman lasers offer great potential for spectroscopic applications, such as resonance…
Atomic spectroscopy studies of short-lived isotopes and nuclear isomer separation with the ISOLDE RILIS
The Resonance Ionization Laser Ion Source (RILIS) at the ISOLDE on-line isotope separator is based on the selective excitation of atomic transitions by tunable laser radiation. Ion beams of isotopes of 20 elements have been produced using the RILIS setup. Together with the mass separator and a particle detection system it represents a tool for high-sensitive laser spectroscopy of short-lived isotopes. By applying narrow-bandwidth lasers for the RILIS one can study isotope shifts (IS) and hyperfine structure (HFS) of atomic optical transitions. Such measurements are capable of providing data on nuclear charge radii, spins and magnetic moments of exotic nuclides far from stability. Although t…
The electron affinity of astatine
One of the most important properties influencing the chemical behavior of an element is the electron affinity (EA). Among the remaining elements with unknown EA is astatine, where one of its isotopes, 211At, is remarkably well suited for targeted radionuclide therapy of cancer. With the At− anion being involved in many aspects of current astatine labeling protocols, the knowledge of the electron affinity of this element is of prime importance. Here we report the measured value of the EA of astatine to be 2.41578(7) eV. This result is compared to state-of-the-art relativistic quantum mechanical calculations that incorporate both the Breit and the quantum electrodynamics (QED) corrections and…
Resonant laser ionization of polonium at rilis-isolde for the study of ground- and isomer-state properties
Three new ionization schemes for polonium have been tested with the resonant ionization laser ion source (RILIS) during the on-line production of 196Po in a UCx target at ISOLDE. The saturation of the atomic transitions has been observed and the yields of the isotope chain 193–198,200,202,204Po have been measured. This development provides the necessary groundwork for performing in-source resonant ionization spectroscopy on the neutron-deficient polonium isotopes (Z = 84). ispartof: Nuclear Instruments & Methods in Physics Research B vol:266 issue:19 pages:4403-4406 ispartof: location:FRANCE, Deauville status: published
Laser photodetachment of radioactive $^{128}$I$^−$
International audience; The first experimental investigation of the electron affinity (EA) of a radioactive isotope has been conducted at the CERN-ISOLDE radioactive ion beam facility. The EA of the radioactive iodine isotope (128)I (t (1/2) = 25 min) was determined to be 3.059 052(38) eV. The experiment was conducted using the newly developed Gothenburg ANion Detector for Affinity measurements by Laser PHotodetachment (GANDALPH) apparatus, connected to a CERN-ISOLDE experimental beamline. (128)I was produced in fission induced by 1.4 GeV protons striking a thorium/tantalum foil target and then extracted as singly charged negative ions at a beam energy of 20 keV. Laser photodetachment of th…
Properties of the 12C 10 MeV state determined through β-decay
16 pages, 1 table, 10 figures.-- PACS nrs.: 23.40.-s; 26.20.+f; 27.20.+n.-- Printed version published Oct 3, 2005.
Ion beam production and study of radioactive isotopes with the laser ion source at ISOLDE
At ISOLDE the majority of radioactive ion beams are produced using the resonance ionization laser ion source (RILIS). This ion source is based on resonant excitation of atomic transitions by wavelength tunable laser radiation. Since its installation at the ISOLDE facility in 1994, the RILIS laser setup has been developed into a versatile remotely operated laser system comprising state-of–the-art solid state and dye lasers capable of generating multiple high quality laser beams at any wavelength in the range of 210–950 nm. A continuous programme of atomic ionization scheme development at CERN and at other laboratories has gradually increased the number of RILIS-ionized elements. At present, …