0000000000133410
AUTHOR
F. Le Blanc
The Collinear Resonance Ionization Spectroscopy (CRIS) experimental setup at CERN-ISOLDE
The CRIS setup at CERN-ISOLDE is a laser spectroscopy experiment dedicated to the high-resolution study of the spin, hyperfine structure and isotope shift of radioactive nuclei with low production rates (a few per second). It combines the Doppler-free resolution of the in-flight collinear geometry with the high detection efficiency of resonant ionisation. A recent commissioning campaign has demonstrated a 1% experimental efficiency, and as low as a 0.001% non-resonant ionisation. The current status of the experiment and its recent achievements with beams of francium isotopes are reported. The first identified systematic effects are discussed. publisher: Elsevier articletitle: The Collinear …
Large Odd-even Radius Staggering In The Very Light Platinum Isotopes From Laser Spectroscopy
Laser spectroscopy measurements have been carried out on very-neutron-deficient platinum isotopes with the COMPLIS experimental setup. Using the ${5d}^{9}{6s}^{3}{D}_{3}\ensuremath{\rightarrow}{5d}^{9}{6p}^{3}{P}_{2}$ optical transition, hyperfine spectra of ${}^{182,181,180,179,178}\mathrm{Pt}$ and ${}^{183}{\mathrm{Pt}}^{m}$ were recorded for the first time. The variation of the mean square charge radius between these nuclei, the magnetic moments of the odd isotopes, and the quadrupole moment of ${}^{183}{\mathrm{Pt}}^{m}$ were thus measured. A large deformation change between ${}^{183}{\mathrm{Pt}}^{g}$ and ${}^{183}{\mathrm{Pt}}^{m},$ an odd-even staggering of the charge radius, and a d…
A dedicated decay-spectroscopy station for the collinear resonance ionization experiment at ISOLDE
A newdecay-spectroscopystation(DSS)has been developed to be coupled to the collinear resonance ionization spectroscopy (CRIS) beam line at CERN-ISOLDE. The system uses a rotatable wheel with ten 20 mg=cm2 carbon foils as beam implantation sites for the efficient measurement of charged decay products. Silicon detectors are placed on either side of the carbon foil in an optimal geometry to cover a large solid angle for detecting these charged particles. In addition to the silicon detectors at the on-beam axis position, a second pair of off-beam axis detectors are placed at the wheel position 108 deg. away, allowing longer-lived species to be studied. Up to three high purity germanium detector…
Kr369660 –Low- Z Boundary of the Island of Deformation at N=60
Prompt γ-ray spectroscopy of the neutron-rich $^{96}$Kr, produced in transfer- and fusion-induced fission reactions, has been performed using the combination of the Advanced Gamma Tracking Array and the VAMOS++ spectrometer. A second excited state, assigned to $J^π$ = $4^+$, is observed for the first time, and a previously reported level energy of the first 2+ excited state is confirmed. The measured energy ratio R4/2 = E($4^+$)/E($2^+$) = 2.12(1) indicates that this nucleus does not show a well-developed collectivity contrary to that seen in heavier N = 60 isotones. This new measurement highlights an abrupt transition of the degree of collectivity as a function of the proton number at Z = …
Hot-cavity studies for the Resonance Ionization Laser Ion Source
International audience; The Resonance Ionization Laser Ion Source (RILIS) has emerged as an important technique in many Radioactive Ion Beam (RIB) facilities for its reliability, and ability to ionize target elements efficiently and element selectively. GISELE is an off-line RILIS test bench to study the implementation of an on-line laser ion source at the GANIL separator facility. The aim of this project is to determine the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. The ion source geometry was tested in several configurations in order to find a solution with optimal ionization efficiency an…
Charge radius changes of even-even neutron-rich Tellurium isotopes
Laser spectroscopy based on resonant ionization of laser-desorbed atoms has been used to study the neutron-rich tellurium isotopes with the COMPLIS facility at ISOLDE-CERN. The isotope shift and the hyperfine structure of several neutron-rich Te isotopes: $^{120–136}$Te and $^{123m–133m}$Te have been measured. From the hyperfine structure and the isotope shift we can extract the magnetic and quadrupole moments and the change in the mean square charge radius respectively. The mean square charge radii of the even-even isotopes have been deduced and their comparison with the known data for the other elements near Z=50 is presented. The experimental $\delta$ is compared with that obtained from …
Optimization of a hot-cavity type resonant ionization laser ion source
TuePS05; International audience; Resonant Ionization Laser Ion Source (RILIS) is nowadays an important technique in many RadioactiveIon Beam (RIB) facilities for its reliability and ability to ionize efficiently and element selectively.Grand Accélérateur National d’Ions Lourds (GANIL) Ion Source using Electron Laser Excitation(GISELE) is an off-line test bench for RILIS developed to study a fully operational resonant laserion source at GANIL facility. The ion source body has been designed as a modular system toinvestigate different experimental approaches by varying the design parameters, to develop the futureon-line laser ion source. The aim of this project is to determine the best technic…
Charge-radius change and nuclear moments in the heavy tin isotopes from laser spectroscopy: Charge radius ofSn132
Laser spectroscopy measurements have been carried out on the neutron-rich tin isotopes with the COMPLIS experimental setup. Using the $5{s}^{2}5{p}^{2\phantom{\rule{0.3em}{0ex}}3}{P}_{0}\ensuremath{\rightarrow}5{s}^{2}5p6s\phantom{\rule{0.3em}{0ex}}{}^{3}{P}_{1}$ optical transition, hyperfine spectra of $^{126\ensuremath{-}132}\mathrm{Sn}$ and $^{125,127,129\ensuremath{-}131}\mathrm{Sn}{}^{m}$ were recorded for the first time. The nuclear moments and the mean square charge radius variation ($\ensuremath{\delta}\ensuremath{\langle}{r}_{c}^{2}\ensuremath{\rangle}$) were extracted. From the quadrupole moment values, these nuclei appear to be spherical. The magnetic moments measured are thus co…
Nuclear Moments and Deformation Change inA184ug,mfrom Laser Spectroscopy
Resonance ionization spectroscopy (RIS) was performed on desorbed Au, and the complete hyperfine spectrum of both isomeric and ground states of the short lived 184Au nucleus has been recorded from the 5d106s S1y2 ! 5d106p P3y2 optical transition. The nuclear moments of both states and the mean square charge radius changes were measured. The magnetic moments were determined to be m 184g I5 12.07s2dmN and m I2 11.44s2dmN and the spectroscopic quadrupole moments to be Q 184g s 14.65s26db and Q184m s 11.90s16d b. A difference in the mean square charge radius dkr2 c l184g,184m 20.036s3d fm2 was found. [S0031-9007(97)03992-6]
Development of the CRIS (Collinear Resonant Ionisation Spectroscopy) beam line
The CRIS (Collinear Resonant Ionisation Spectroscopy) beam line is a new experimental set up at the ISOLDE facility at CERN. CRIS is being constructed for highresolution laser spectroscopy measurements on radioactive isotopes. These measurements can be used to extract nuclear properties of isotopes far from stability. The CRIS beam line has been under construction since 2009 and testing of its constituent parts have been performed using stable and radioactive ion beams, in preparation for its first on-line run. This paper will present the current status of the CRIS experiment and highlight results from the recent tests. ispartof: pages:012070-6 ispartof: Journal of Physics: Conference Serie…
Trial for the long neutron counter TETRA using $^{96,97}$Rb radioactive sources
International audience; The TETRA long neutron counter is operated at ALTO ISOL facility behind the PARRNe mass separator. TETRA has been proven to be a unique instrument for measurements of β-decay properties of short-lived neutron-rich nuclei having applications for the nuclear structure and/or astrophysical r-process calculations. A proper calibration of TETRA can allow validation of the experimental procedure used for determination of β-delayed one-neutron emission probabilities (P1n). It requires the use of a well-known β-neutron decaying radioactive source which can be only produced and measured on-line due to its short half-life. Thus, the present paper reports on measurements of P1n…
Laser assisted decay spectroscopy at the CRIS beam line at ISOLDE
A new collinear resonant ionization spectroscopy (Cris)beam line has recently been installed at Isolde, Cern utilising lasers to combine collinear laser spectroscopy and resonant ionization spectroscopy. The combined technique offers the ability to purify an ion beam that is heavily contaminated with radioactive isobars, including the ground state of an isotope from its isomer, allowing sensitive secondary experiments to be performed. A new programme aiming to use the Cris technique for the separation of nuclear isomeric states for decay spectroscopy will commence in 2011. A decay spectroscopy station, consisting of a rotating wheel implantation system for alpha decay spectroscopy, and thre…
Charge radius change in the heavy tin isotopes until A = 132 from laser spectroscopy
Laser spectroscopy measurements have been carried out on the very neutron-rich tin isotopes with the COMPLIS experimental setup. Using the 5s 25p 23P 0 → 5s 25p6s 3P 1 optical transition, hyperfine spectra of 126-132Sn and 125m, 127m, 129m-131mSn where recorded for the first time. The variation of the mean-square charge radius ( δ〈r 2〉) between these nuclei and nuclear moments of the isomers and the odd isotopes were thus measured. An odd-even staggering which inverts at A = 130 is clearly observed. This indicates a small appearance of a plateau on the δ〈r 2〉 which has to be confirmed by measuring the isotope shift beyond A = 132.
AGATA-Advanced GAmma Tracking Array
WOS: 000300864200005