0000000000141106

AUTHOR

Antonio Pallarés

showing 6 related works from this author

A comparative study of the sealing ability of two root canal obturation techniques

1995

A comparison was made of the ability of two root canal obturating techniques to prevent dye microleakage: gutta-percha lateral condensation and mechanically plasticized gutta-percha (JS Quick-fill). Twenty central incisors were prepared and obturated by each technique. After rendering the teeth transparent, linear dye penetration was found to be 0.48 and 0.52 mm, respectively. The difference between the two techniques was not significant. As for the distribution of the sealing cement (AH26) in the teeth obturated with JS Quickfill, the cement was located in the most peripheral zone of the obturation alongside the dentinal walls, whereas the gutta-percha was found in the central part of the …

Dental LeakageDye penetrationCementJS-quickfillRoot Canal ObturationMaterials sciencebusiness.industryRoot canalDentistryLateral condensationIncisorstomatognathic diseasesPeripheral zonemedicine.anatomical_structurestomatognathic systemEvaluation Studies as TopicRoot Canal ObturationmedicineHumansMaxillary central incisorGutta-PerchabusinessGeneral DentistryJournal of Endodontics
researchProduct

A Comparative Study of Cyclic Fatigue of 10 Different Types of Endodontic Instruments: an in Vitro Study

2019

Objective This study was designed to test the null hypothesis that there were no significant differences between size 25 files F360, F6 SkyTaper, Hyflex EDM, iRace, Neoniti, One Shape Protaper Next, Reciproc, Revo-S and Wave One Gold in terms of resistance to cyclic fatigue and length of broken fragments. Material and methods 300 new size 25 files of the systems studied were selected (n=30). The instruments were mechanized with a X-Smart Plus endo motor at the speed and torque recommended by the manufacturer, holding the instruments steady with a clamping mechanism, with passive adjustment and without pressure in a stainless-steel block. The time was calculated in seconds until fracture. Th…

OrthodonticsCyclic stress030206 dentistry02 engineering and technology021001 nanoscience & nanotechnologyConfidence intervalDental High-Speed Equipment03 medical and health sciences0302 clinical medicineTorqueMultiple comparisons problemIn vitro studyCalipersStatistical analysis0210 nano-technologyOriginal Scientific PapersGeneral DentistryFatigueMathematicsActa Stomatologica Croatica
researchProduct

In vitro istraživanje apikalnog mikropropuštanja pet tehnika punjenja kanala

2014

Aim A comparison was made between the root canal lateral condensation technique and other condensation techniques in which physical (temperature: Soft-Core®, Obtura II®) or chemical changes (condensation: Guttaflow®, Resilon®) may affect the dimensional stability of obturation and thus favor apical microleakage. Materials and methods A total of 212 single-root teeth removed for orthodontic or periodontal reasons were randomized to 5 groups of 40 teeth each. Six samples were used as positive controls, and another 6 as negative controls. The teeth were worked with the Hero 642 system, and each group was obturated using a different technique: lateral condensation, Obtura II®, Soft-Core®, Gutta…

Root Canal ObturationMaterials sciencebusiness.industryRoot canalDentistryRoot Canal Filling MaterialsLateral condensationmedicine.anatomical_structureSoft coreStereo microscopemedicineIn vitro studyStatistical analysisbusinessGeneral DentistryActa Stomatologica Croatica
researchProduct

Komparativno istraživanje oblikovanja četiriju rotirajućih sustava

2015

Svrha: U ovom istraživanju analizirali smo rezno područje, vrijeme instrumentacije, održavanje anatomije korijenskog kanala i neinstrumentirana područja dobivena korištenjem instrumenata F360®, Mtwo®, RaCe® i Hyflex® u ISO veličini 35. Materijali i metode: Odabrano je 120 zuba s jednim ravnim kanalom i podijeljeni su u četiri grupe. Radna duljina određena je radiološki. Zubi su rezani dijamantnim diskom, a presjeci su promatrani stereoskopskim mikroskopom Nikon SMZ-2T pod svjetiljkom Intralux 4000-1. Grupe su oblikovane predoperativnom analizom AutoCAD. Zubi su rekonstruirani s pomoću K-proširivača #10 i epoksi ljepila. Svaka grupa instrumentirana je jednim od četiriju sustava. Vrijeme inst…

OrthodonticsInstrumentationRoot canalTooth PreparationA diamondDental High-Speed Equipmentlcsh:RK1-715Light sourcemedicine.anatomical_structurelcsh:DentistryStereo microscopemedicineStatistical analysispreparacija korijenskog kanala brzo rotirajuća stomatološka oprema priprema zuba; poprečni presjecicross-sectionsRoot canal anatomyRoot Canal Preparation; Dental High-Speed Equipment; Tooth Preparation; cross-sectionsGeneral DentistryRoot Canal PreparationResearch ArticleMathematicsActa Stomatologica Croatica
researchProduct

Comparison of Shaping Ability of 10 Rotary and Reciprocating Systems: an In Vitro Study with AutoCAD

2017

Cilj: Usporediti reznu površinu, očuvanje anatomije korijenskog kanala i neinstrumentiranu površinu nakon instrumentacije sustavima F360®, F6SkyTaper®, HyflexEDM®, iRace®, Neoniti®, O.Shape®, P.Next®, Reciproc®, Revo-S® i WaveOneGold® s veličinom instrumenta 25. Materijali i metode: Tristo zubi s jednim ravnim korijenom i okruglim ili eliptičnim presjekom korijenskog kanala podijeljeno je u 10 skupina (1-F360®, 2-F6SkyTaper®, 3-HyflexEDM®, 4-iRace®, 5-Neoniti®, 6-O Shape®, 7-P.Next®, 8-Reciproc®, 9-Revo-S® i 10-WaveOneGold®) i poprečno prerezano na trećine ultrafinim reznim diskovima. Uzorci su fotografirani pod stereomikroskopom i provedena je predinstrumentacijska analiza prije ponovnog s…

OrthodonticsRoot Canal Preparation; Dental HighSpeed EquipmentDental HighSpeed EquipmentRoot canal0206 medical engineering030206 dentistry02 engineering and technology020601 biomedical engineeringlcsh:RK1-715korijenski kanal priprema; brzo rotirajuća stomatološka oprema03 medical and health sciencesReciprocating motion0302 clinical medicinemedicine.anatomical_structurelcsh:DentistryCoronal planeStereo microscopemedicineIn vitro studyStatistical analysisOriginal Scientific PapersRoot canal anatomyGeneral DentistryRoot Canal PreparationMathematicsActa Stomatologica Croatica
researchProduct

An in vivo comparative study of two apex locators

1994

Two different electronic apex locators were used before extraction to determine working length in 116 root canals belonging to 34 molars. The results were then compared with postextraction working length measurements. The determinations were made before and after eliminating the canal contents and drying the interior. The results showed that 84.8% and 79.3% of the Odometer, and 89.6% and 88.7% of the Endocater readings for dry and nondry canals, respectively, occurred within the two 0.5-mm intervals closest to the apical constriction.

Molarbusiness.industryReproducibility of ResultsWaterDentistryApical constrictionMolarRoot Canal TherapyApex (geometry)Evaluation Studies as TopicHumansOdontometryDental Pulp CavityTooth RootbusinessGeneral DentistryMathematicsJournal of Endodontics
researchProduct