0000000000141131

AUTHOR

Sandra-liliana Gómez-gómez

Comparison of frictional resistance between passive self-ligating brackets and slide-type low-friction ligature brackets during the alignment and leveling stage

Background To compare the frictional resistance between passive self-ligating brackets and conventional brackets with low-friction ligature under bracket/archwire and root/bone interface during dental alignment and leveling. Material and methods A tridimensional model of the maxilla and teeth of a patient treated with conventional brackets, and slide ligatures was generated employing the SolidWorks modeling software. SmartClip self-ligating brackets and Logic Line conventional brackets were assembled with slide low-friction ligatures, utilizing archwires with different diameters and alloys used for the alignment and leveling stage. Friction caused during the bracket/archwire interface and s…

research product

Comparison of frictional forces during the closure of extraction spaces in passive self-ligating brackets and conventionally ligated brackets using the finite element method.

Background This study compared the frictional force resulting from the bracket/archwire interface and the stress at the root/periodontal ligament/bone interface, between passive self-ligating brackets and conventionally ligated brackets, during the space closure stage. Material and methods A cone beam tomography was taken to a female patient that required extraction of upper first premolars and passive self-ligating system; three months after its activation, a cone beam tomography was taken again. The designs of the maxillary bone and the entire system were possible through tomography images and stereomicroscopic photographs. Validation of the Finite Element Method (FEM) was achieved compar…

research product

Influence of Hyrax screw position on dental movement and cortical bone : a study of finite elements

Background Rapid maxillary expansion (RME) has effects on the dental and periodontal structures of the parts involved, which vary according to the design and position of the expansion screw. The purpose of the study was to determine the optimal three-dimensional position of the Hyrax screw to obtain precise control of the dental movement and effect on the bone cortex using the finite element method (FEM). Material and methods RME was performed from the patient whom two Cone-Beam computerized tomography scans (CBCT) were obtained: T1 before expansion, and T2 three months after stabilization of RME. The FEM model was designed with T1 and of Hyrax photographs. FEM was obtained by comparing the…

research product