0000000000142131

AUTHOR

J. Cañada

Design of a sun tracker for the automatic measurement of spectral irradiance and construction of an irradiance database in the 330-1100 nm range

Abstract An automatic global and direct solar spectral irradiance system has been designed based on two LICOR spectroradiometers equipped with fibre optics and remote cosine sensors. To measure direct irradiance a sun tracker based on step motors has been developed. The whole system is autonomous and works continuously. From the measurements provided by this system a spectral irradiance database in the 330–1100 nm range has been created. This database contains normal direct and global horizontal irradiances as well as diffuse irradiance on a horizontal plane, together with total atmospheric optical thickness and aerosol optical depth.

research product

Aerosol optical characteristics from a summer campaign in an urban coastal Mediterranean area

The authors present a preliminary study of some optical properties of atmospheric aerosols over the area of Valencia, Spain, a coastal Mediterranean city. Measurements of spectral direct irradiance in the 300-1100 nm range were taken simultaneously at three sites: rural-continental, rural-coastal, and urban-coastal, all located within a 50 km radius of the city of Valencia. The irradiance measurements were obtained using three Li-cor 1800 spectroradiometers provided with radiance limiting tubes with field of views (FOVs) of 4.7/spl deg/. The measurements were made under clear sky conditions during a field campaign carried out in the summer of 1998. In order to avoid the uncertainties associ…

research product

A comparative study of SPCTRAL2 and SMARTS2 parameterised models based on spectral irradiance measurements at Valencia, Spain

Abstract Results obtained using the parametric models SPCTRAL2 and SMARTS2 for the urban area of Valencia, Spain, have been analysed and compared with experimental measurements at ground level obtained with two Li-cor 1800 spectroradiometers with a 6 nm resolution. The study used two different input parameters in both models for the aerosol characterisation: the aerosol optical thickness at 0.5  μ m, τ a λ (0.5) , and the Angstrom turbidity coefficient β . The results obtained show that both algorithms reproduce quite correctly the spectral irradiance experimental values when an urban aerosol model parameterised by the τ a λ (0.5) value is considered. In all the cases the deviations are low…

research product

Study of erythemal, UV (A + B) and global solar radiation in Valencia (Spain)

Although ultraviolet B radiation (UVB), the solar radiation band between 280 and 315 nm, is only a small fraction of the extraterrestrial solar radiation, it accounts for 80% of the harmful effects of exposure to the sun. In this work values of erythemal solar irradiance (UVER) measured in Valencia on a horizontal plane in the period between June 2003 and June 2005 are analysed and compared with measures of UV (A+B) and global irradiances on a horizontal plane. UV erythemal (UVER) irradiance has been measured using a YES-UVB-1 broadband radiometer; UV (A+B) irradiance has been measured using a TUVR Eppley radiometer with spectral response between 290 and 385 nm and global irradiance on a ho…

research product

Intercomparison of spectroradiometers and Sun photometers for the determination of the aerosol optical depth during the VELETA-2002 field campaign

In July 2002 the VELETA-2002 field campaign was held in Sierra Nevada (Granada) in the south of Spain. The main objectives of this field campaign were the study of the influence of elevation and atmospheric aerosols on measured UV radiation. In the first stage of the field campaign, a common calibration and intercomparison between Licor-1800 spectroradiometers and Cimel-318 Sun photometers was performed in order to assess the quality of the measurements from the whole campaign. The intercomparison of the Licor spectroradiometers showed, for both direct and global irradiances, that when the comparisons were restricted to the visible part of the spectrum the deviations were within the instrum…

research product

UV Index on Tilted Surfaces

Solar ultraviolet erythemal irradiance (UVER) has been studied on inclined planes with different orientations in Valencia, Spain. To do this a platform was designed that could turn through 90 degrees on its own axis. The radiometers were inclined at an angle close to the latitude of Valencia (39.5 degrees N). Using two timers the platform could be turned through 90 degrees every 5 min. On clear or partially cloudy days, including those with different turbidity values, it was observed that the UVER showed a maximum at 1200 h GMT, very close to solar noon, in the north and south positions, while the maximum for east and west orientations was found at approximately one hour before and one hour…

research product

The erythemal clearness index for Valencia, Spain

The values of three clearness indices have been measured for the city of Valencia: kt, the clearness index for the whole solar spectrum, ktUV the clearness index for the ultraviolet range, and the erythemal clearness index for the erythemal radiation ktUVER, corresponding to the solar radiation weighted by the erythemal action spectrum on human skin, normalized with respect to the solar constant corresponding to that spectrum. The measurements of ktUV reached values that were approximately 54% of that corresponding to kt, while those of ktUVER were much smaller. Some statistics of the erythemal clearness index have been calculated both for monthly as well as hourly means. The shape of the d…

research product

Diffuse ultraviolet erythemal irradiance on inclined planes: a comparison of experimental and modeled data.

Values of measured and modeled diffuse UV erythemal irradiance (UVER) for all sky conditions are compared on planes inclined at 40 degrees and oriented north, south, east and west. The models used for simulating diffuse UVER are of the geometric-type, mainly the Isotropic, Klucher, Hay, Muneer, Reindl and Schauberger models. To analyze the precision of the models, some statistical estimators were used such as root mean square deviation, mean absolute deviation and mean bias deviation. It was seen that all the analyzed models reproduce adequately the diffuse UVER on the south-facing plane, with greater discrepancies for the other inclined planes. When the models are applied to cloud-free con…

research product

Column-integrated aerosol optical properties in the free troposphere: case study-Sierra Nevada, Spain

From spectral solar irradiance extinction measurements in the visible range carried out at Sierra Nevada (2950 m a.s.l.) during July 1998, the characteristics of the aerosol column in the free troposphere have been measured. The results show that in stable atmospheric conditions, the column-integrated aerosol takes an optical depth (AOD) at 500 nm of 0.02 /spl plusmn/ 0.02, and an average radius in the accumulation mode of 0.15 /spl mu/m, with a likely Atlantic origin. In unstable situations, the AOD at 500 nm can increase by more than an order of magnitude, and the aerosols' origin is uncertain, since air masses can arrive from different sources at different altitudes.

research product

Ozone mini-holes over Valencia (Spain) and their influence on the UV erythemal radiation

Low ozone level episodes (also known as mini-holes) have been analysed over Valencia, Spain, during the period from 1 January 2000 to 31 December 2007. In this study, 24 episodes, lasting 1 or 2 days each, were detected. Most of them can be explained dynamically by the existence of an anticyclone over the Azores, which sends air masses coming from the Caribbean over the Iberian Peninsula. A positive anomaly in the vertical temperature profile in the high troposphere and one negative anomaly in the medium and low stratosphere are also observed in most of the analysed episodes. The total ozone column decrease is accompanied by a rise in the UV erythemal radiation levels. This increase is quan…

research product

Diffuse UV erythemal radiation experimental values

[1] Measurements of diffuse UV erythemal radiation (UVER) using a shadowband have been corrected using the models proposed by Drummond (1956), LeBaron et al. (1990), and Batlles et al. (1995). Two different methods were used to validate these models: intercomparison with an Optronic OL754 spectroradiometer and comparison with the values simulated by two radiative transfer codes, SMARTS and SBDART. For this comparison only clear days have been used. The corrected experimental values were analyzed in order to study the average values of the diffuse UVER fraction in relation to the clearness index kt. These varied between 62%, for kt close to 0.8, and 93% for kt of 0.2–0.3. Finally, a study of…

research product