0000000000150121

AUTHOR

F. Kuchler

showing 4 related works from this author

New constraints on Lorentz invariance violation from the neutron electric dipole moment

2010

We propose an original test of Lorentz invariance in the interaction between a particle spin and an electromagnetic field and report on a first measurement using ultracold neutrons. We used a high sensitivity neutron electric dipole moment (nEDM) spectrometer and searched for a direction dependence of a nEDM signal leading to a modulation of its magnitude at periods of 12 and 24 hours. We constrain such a modulation to $d_{12} < 15 \times 10^{-25} \ e\,{\rm cm}$ and $d_{24} < 10 \times 10^{-25} \ e\,{\rm cm}$ at 95~\% C.L. The result translates into a limit on the energy scale for this type of Lorentz violation effect at the level of ${\cal E}_{LV} > 10^{10}$~GeV.

Electromagnetic fieldPhysicsSpectrometerNeutron electric dipole moment010308 nuclear & particles physicsFOS: Physical sciencesGeneral Physics and AstronomyLorentz covariance[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesSignalModulationQuantum electrodynamics0103 physical sciencesUltracold neutronsSensitivity (control systems)Nuclear Experiment (nucl-ex)Nuclear Experiment010306 general physicsNuclear Experiment
researchProduct

Neutron to mirror-neutron oscillations in the presence of mirror magnetic fields

2009

We performed ultracold neutron (UCN) storage measurements to search for additional losses due to neutron (n) to mirror-neutron (n') oscillations as a function of an applied magnetic field B. In the presence of a mirror magnetic field B', UCN losses would be maximal for B = B'. We did not observe any indication for nn' oscillations and placed a lower limit on the oscillation time of tau_{nn'} > 12.0 s at 95% C.L. for any B' between 0 and 12.5 uT.

PhysicsNuclear and High Energy PhysicsAntiparticle010308 nuclear & particles physicsOscillationAstrophysics::High Energy Astrophysical PhenomenaFOS: Physical sciencesHardware_PERFORMANCEANDRELIABILITYFermion[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences3. Good healthMagnetic fieldNuclear physicsTheoryofComputation_ANALYSISOFALGORITHMSANDPROBLEMCOMPLEXITYAntimatter0103 physical sciencesUltracold neutronsNeutronNuclear Experiment (nucl-ex)010306 general physicsNucleonNuclear ExperimentNuclear Experiment
researchProduct

Test of Lorentz invariance with spin precession of ultracold neutrons

2009

A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms is reported. %57 No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field $b_{\bot} < 2 \times 10^{-20} {\rm eV}$ (95% C.L.). This is the first limit for the free neutron. This result is also interpreted as a direct limit on the gravitational dipole moment of the neutron $|g_n| < 0.3 $eV/$c^2$ m from a spin-dependent interaction with the Sun. Analyzing the gravitational interaction with the Earth, based on previous data, yields a more stringent limit $|g_n| < 3 \times …

Physics010308 nuclear & particles physicsGeneral Physics and AstronomyFOS: Physical sciencesElementary particleLorentz covariance[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyDipoleQuantum mechanics0103 physical sciencesPrecessionUltracold neutronsNeutronAtomic physicsNuclear Experiment (nucl-ex)010306 general physicsNucleonSpin (physics)Nuclear Experiment
researchProduct

Towards a new measurement of the neutron electric dipole moment

2009

International audience; The effort towards a new measurement of the neutron electric dipole moment (nEDM) at the Paul Scherrer Institut's (PSI) new high intensity source of ultracold neutrons (UCN) is described. The experimental technique relies on Ramsey's method of separated oscillatory fields, using UCN in vacuum with the apparatus at ambient temperature. In the first phase, R&D towards the upgrade of the RAL/Sussex/ILL apparatus is being performed at the Institut Laue-Langevin (ILL). In the second phase the apparatus, moved from ILL to PSI, will allow an improvement in experimental sensitivity by a factor of 5. In the third phase, a new spectrometer should gain another order of magnitud…

PhysicsNuclear and High Energy PhysicsTime reversal violationElectric dipole momentSpectrometerNeutron electric dipole momentPhysics::Instrumentation and Detectors010308 nuclear & particles physicsMagnetometerPhase (waves)[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]7. Clean energy01 natural sciencesMagnetic fieldlaw.inventionElectric dipole momentlawElectric field0103 physical sciencesUltracold neutronsAtomic physicsUltracold neutronsNuclear Experiment010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct