Optimal Response to Cardiac Arrest study: Defibrillation waveform effects
Abstract Introduction: Advances in early defibrillation access, key to the “Chain of Survival”, will depend on innovations in defibrillation waveforms, because of their impact on device size and weight. This study compared standard monophasic waveform automatic external defibrillators (AEDs) to an innovative biphasic waveform AED. Material and methods: Impedance-compensated biphasic truncated exponential (ICBTE) and either monophasic truncated exponential (MTE) or monophasic damped sine (MDS) AEDs were prospectively, randomly assigned by date in four emergency medical services. The study design compared ICBTE with MTE and MDS combined. This subset analysis distinguishes between the two clas…
Rationale and design of the EMBRACE STEMI Study: A phase 2a, randomized, double-blind, placebo-controlled trial to evaluate the safety, tolerability and efficacy of intravenous Bendavia on reperfusion injury in patients treated with standard therapy including primary percutaneous coronary intervention and stenting for ST-segment elevation myocardial infarction
Background Although significant efforts have been made to improve ST-segment elevation myocardial infarction (STEMI) outcomes by reducing symptom-onset-to-reperfusion times, strategies to decrease the clinical impact of ischemic reperfusion injury have demonstrated limited success. Bendavia, an intravenously administered mitochondrial targeting peptide, has been shown to reduce myocardial infarct size and attenuate coronary no-reflow in experimental modelswhen given before reperfusion. Design The EMBRACE STEMI study is a phase 2a, randomized, double-blind, placebo-controlled trial enrolling 300 patients with a first-time anterior STEMI and an occluded proximal or mid–left anterior descendin…
Multicenter, Randomized, Controlled Trial of 150-J Biphasic Shocks Compared With 200- to 360-J Monophasic Shocks in the Resuscitation of Out-of-Hospital Cardiac Arrest Victims
Background —In the present study, we compared an automatic external defibrillator (AED) that delivers 150-J biphasic shocks with traditional high-energy (200- to 360-J) monophasic AEDs. Methods and Results —AEDs were prospectively randomized according to defibrillation waveform on a daily basis in 4 emergency medical services systems. Defibrillation efficacy, survival to hospital admission and discharge, return of spontaneous circulation, and neurological status at discharge (cerebral performance category) were compared. Of 338 patients with out-of-hospital cardiac arrest, 115 had a cardiac etiology, presented with ventricular fibrillation, and were shocked with an AED. The time from the e…