0000000000162415

AUTHOR

B. Guillon

showing 13 related works from this author

Measurement of the background in the NEMO 3 double beta decay experiment

2009

In the double beta decay experiment NEMO 3 a precise knowledge of the background in the signal region is of outstanding importance. This article presents the methods used in NEMO 3 to evaluate the backgrounds resulting from most if not all possible origins. It also illustrates the power of the combined tracking-calorimetry technique used in the experiment.

Nuclear and High Energy Physicscongenital hereditary and neonatal diseases and abnormalitiesSignal regionchemistry.chemical_elementFOS: Physical sciencesRadon[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesNuclear physicsNEMODouble beta decay0103 physical sciencesNeutrino Ettore Majorana ObservatoryNuclear Experiment (nucl-ex)010306 general physicsskin and connective tissue diseasesLow radioactivityInstrumentationNuclear ExperimentPhysics010308 nuclear & particles physicsDetectorDouble beta decayPower (physics)BackgroundchemistryRadon
researchProduct

Results of the search for neutrinoless double-βdecay inMo100with the NEMO-3 experiment

2015

The NEMO-3 detector, which had been operating in the Modane Underground Laboratory from 2003 to 2010, was designed to search for neutrinoless double $\beta$ ($0\nu\beta\beta$) decay. We report final results of a search for $0\nu\beta\beta$ decays with $6.914$ kg of $^{100}$Mo using the entire NEMO-3 data set with a detector live time of $4.96$ yr, which corresponds to an exposure of 34.3 kg$\cdot$yr. We perform a detailed study of the expected background in the $0\nu\beta\beta$ signal region and find no evidence of $0\nu\beta\beta$ decays in the data. The level of observed background in the $0\nu\beta\beta$ signal region $[2.8-3.2]$ MeV is $0.44 \pm 0.13$ counts/yr/kg, and no events are obs…

PhysicsNuclear and High Energy PhysicsParticle physics010308 nuclear & particles physicsSignal region01 natural sciencesBeta decayLower limitNuclear physicsMAJORANADouble beta decay0103 physical sciencesUnderground laboratoryBeta (velocity)Neutrino010306 general physicsPhysical Review D
researchProduct

Spectral modeling of scintillator for the NEMO-3 and SuperNEMO detectors

2010

We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is improved if wavelength-dependent properties of the calorimeter are taken into account. In this article, we briefly describe our modeling approach and results of our studies.

Nuclear and High Energy PhysicsPhotomultiplierTechnologyPhysics - Instrumentation and DetectorsPhotonPhysics::Instrumentation and DetectorsCODEFOS: Physical sciencesScintillator01 natural sciencesHigh Energy Physics - ExperimentPhysics Particles & FieldsNuclear physicsHigh Energy Physics - Experiment (hep-ex)Photomultiplier0202 Atomic Molecular Nuclear Particle And Plasma PhysicsDouble beta decay0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]CalibrationPlastic scintillators[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsNuclear Science & TechnologyInstrumentationInstruments & InstrumentationScintillationphysics.ins-detPhysicsScintillationScience & Technology010308 nuclear & particles physicshep-exPhysicsMO-100DetectorInstrumentation and Detectors (physics.ins-det)Double beta decayNuclear & Particles PhysicsCalorimeterPhysics NuclearPhysical SciencesGEANT 4DOUBLE-BETA DECAYOptical photon transport
researchProduct

An innovative lipid-lowering approach to enhance attainment of low-density lipoprotein cholesterol goals

2020

Aims To improve attainment of LDL-cholesterol (LDL-c) targets, an expert group proposed an algorithm for lipid-lowering therapy during hospitalization for acute coronary syndrome and during follow-up. We aimed to assess adherence to this algorithm, and evaluate its impact on LDL-c levels and on attainment of therapeutic LDL-c targets in a population of post-acute coronary syndrome patients. Methods and results Prospective, observational study including patients admitted for acute coronary syndrome between February 2017 and September 2018. Patients admitted without statins or ezetimibe were considered ‘naïve’. Baseline LDL-c was admission LDL-c in naïve patients, and for those taking lipid-…

Malemedicine.medical_specialtyAcute coronary syndromeStatinmedicine.drug_classLow density lipoprotein cholesterol030204 cardiovascular system & hematologyCritical Care and Intensive Care MedicineLipid-lowering therapy03 medical and health sciences0302 clinical medicineEzetimibeInternal medicinemedicineHumansProspective Studies030212 general & internal medicineAcute Coronary SyndromeAgedbusiness.industryAnticholesteremic AgentsCholesterol LDLGeneral MedicineEzetimibePrognosismedicine.diseaseExpert groupHospitalizationCardiologyPatient ComplianceLDL Cholesterol LipoproteinsFemalelipids (amino acids peptides and proteins)Lipid loweringCardiology and Cardiovascular MedicinebusinessAlgorithmsBiomarkersFollow-Up Studiesmedicine.drugEuropean Heart Journal. Acute Cardiovascular Care
researchProduct

Measurement of the two neutrino double beta decay half-life of Zr-96 with the NEMO-3 detector

2010

Using 9.4 g of Zr-96 and 1221 days of data from the NEMO-3 detector corresponding to 0.031 kg yr, the obtained 2vbb decay half-life measurement is [2.35 +/- 0.14(stat) +/- 0.16(syst)] x 10^19 yr. Different characteristics of the final state electrons have been studied, such as the energy sum, individual electron energy, and angular distribution. The 2v nuclear matrix element is extracted using the measured 2vbb half-life and is 0.049 +/- 0.002. Constraints on 0vbb decay have also been set.

PhysicsNuclear and High Energy PhysicsIsotope010308 nuclear & particles physicsDetectorFOS: Physical sciencesHalf-lifeElectron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]7. Clean energy01 natural sciencesNuclear physicsRadioactivityAngular distributionDouble beta decay0103 physical sciencesNuclear Experiment (nucl-ex)Neutrino010306 general physicsNuclear ExperimentEnergy (signal processing)
researchProduct

Outcomes after extracorporeal membrane oxygenation for the treatment of high-risk pulmonary embolism: a multicentre series of 52 cases

2018

International audience; Aims The role of extracorporeal membrane oxygenation (ECMO) remains ill defined in pulmonary embolism (PE). We investigated outcomes in patients with high-risk PE undergoing ECMO according to initial therapeutic strategy. Methods and results From 01 January 2014 to 31 December 2015, 180 patients from 13 Departments in nine centres with high-risk PE were retrospectively included. Among those undergoing ECMO, we compared characteristics and outcomes according to adjunctive treatment strategy (systemic thrombolysis, surgical embolectomy, or no reperfusion therapy). Primary outcome was all-cause 30-day mortality. Secondary outcome was 90-day major bleeding. One hundred a…

Malemedicine.medical_specialtymedicine.medical_treatment[SDV]Life Sciences [q-bio]Embolectomy030204 cardiovascular system & hematologyEmbolectomy03 medical and health sciences0302 clinical medicineReperfusion therapyExtracorporeal Membrane OxygenationFibrinolysismedicineExtracorporeal membrane oxygenationHumans030212 general & internal medicineRetrospective Studiesbusiness.industryRetrospective cohort studyThrombolysisMiddle Agedmedicine.diseasePrognosisPulmonary embolismSurgerySurvival Rate[SDV] Life Sciences [q-bio]surgical procedures operativeEchocardiographyAdjunctive treatmentFemaleFranceCardiology and Cardiovascular MedicinebusinessPulmonary EmbolismFollow-Up Studies
researchProduct

Measurement of theββDecay Half-Life ofTe130with the NEMO-3 Detector

2011

This Letter reports results from the NEMO-3 experiment based on an exposure of 1275 days with 661g of 130Te in the form of enriched and natural tellurium foils. With this data set the double beta decay rate of 130Te is found to be non-zero with a significance of 7.7 standard deviations and the half-life is measured to be T1/2 = (7.0 +/- 0.9(stat) +/- 1.1(syst)) x 10^{20} yr. This represents the most precise measurement of this half-life yet published and the first real-time observation of this decay.

PhysicsIsotope010308 nuclear & particles physicsStable isotope ratioGeneral Physics and AstronomyHalf-lifechemistry.chemical_element01 natural sciencesBeta decayNuclear physicschemistryDouble beta decay0103 physical sciencesNeutrino Ettore Majorana Observatory010306 general physicsTelluriumRadioactive decayPhysical Review Letters
researchProduct

Detailed studies of $^{100}$Mo two-neutrino double beta decay in NEMO-3

2019

The full data set of the NEMO-3 experiment has been used to measure the half-life of the two-neutrino double beta decay of $^{100}$Mo to the ground state of $^{100}$Ru, $T_{1/2} = \left[ 6.81 \pm 0.01\,\left(\mbox{stat}\right) ^{+0.38}_{-0.40}\,\left(\mbox{syst}\right) \right] \times10^{18}$ y. The two-electron energy sum, single electron energy spectra and distribution of the angle between the electrons are presented with an unprecedented statistics of $5\times10^5$ events and a signal-to-background ratio of ~80. Clear evidence for the Single State Dominance model is found for this nuclear transition. Limits on Majoron emitting neutrinoless double beta decay modes with spectral indices of …

Particle physicsS029MTPhysics and Astronomy (miscellaneous)FOS: Physical sciencesElementary particle[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]nucl-exinvariance: Lorentz01 natural sciences7. Clean energyneutrinoless double beta decaydecay modesPhysics Particles & Fieldsdouble-beta decay: (0neutrino)SEARCHDouble beta decay0103 physical sciencesground stateNuclear Experiment (nucl-ex)010306 general physics0206 Quantum PhysicsEngineering (miscellaneous)Nuclear ExperimentMajoronS076H2NPhysicsScience & TechnologyHALF-LIFE010308 nuclear & particles physicsPhysicsMO-100High Energy Physics::PhenomenologyNuclear & Particles PhysicsMajoronviolation: Lorentznucleus: transitionSTATESstatisticsPhysical Sciences0202 Atomic Molecular Nuclear Particle and Plasma Physicsspectralelectron: energy spectrumHigh Energy Physics::ExperimentNeutrinoGround stateEnergy (signal processing)Radioactive decayLepton
researchProduct

To assess hemodynamic disturbances to the ostia of the renal arteries generated by the implantation of EVAR with a suprarenal fixation

2020

Abstract Introduction: The treatment of abdominal aortic aneurysm (AAA) is increasingly performed via endovascular aneurysm repair (EVAR). Different types of fixation are possible with EVAR, i.e., below (infrarenal fixation) or above (suprarenal fixation) the renal arteries. Hemodynamic alterations in renal arterial flow with suprarenal (SR) fixation remain to be demonstrated. The IFIXEAR (Impact of Supra-renal Fixation of EVAR on Hemodynamics of Renal Arteries) study is designed to assess the hemodynamic effects at the ostia of at least 1 renal artery, generated immediately post-surgery by the implantation of an aortic stent with SR fixation. Methods: IFIXEAR is a prospective, 2 center stu…

Malemedicine.medical_specialty3400medicine.medical_treatmentaortic aneurysm abdominalHemodynamicsEndovascular aneurysm repair03 medical and health sciencesAortic aneurysm0302 clinical medicineRenal ArteryStudy Protocol Clinical Trialmedicine.arterymedicineClinical endpointHumans030212 general & internal medicineRenal arteryFixation (histology)renal artery stenosisbusiness.industryEndovascular ProceduresHemodynamicsGeneral Medicinemedicine.diseaseAbdominal aortic aneurysmSurgery030220 oncology & carcinogenesisFemalebusinessAbdominal surgeryResearch ArticleAortic Aneurysm AbdominalMedicine
researchProduct

Incidence, Predictors, and Impact on Six-Month Mortality of Three Different Definitions of Contrast-Induced Acute Kidney Injury After Coronary Angiog…

2017

We assessed incidence, predictors, and impact on 6-month mortality of contrast-induced acute kidney injury (CI-AKI) after coronary angiography with or without percutaneous coronary intervention in patients with acute coronary syndrome (ACS), according to 3 different CI-AKI definitions. Serum creatinine (sCr) was assessed at baseline and 48 to 72 hours after procedure to classify patients into 3 CI-AKI groups: Group 1: increase in sCR ≥25% over baseline but absolute increase 25% in the remaining 844 (84.2%). CI-AKI was significantly associated with 6-month all-cause mortality using the definitions for Group 2 (hazard ratio 3.1, 95% confidence interval [CI] 1.5 to 6.6, p = 0.002) and Group 3 …

Malemedicine.medical_specialtyAcute coronary syndromemedicine.medical_treatmentPopulationRenal functionContrast Media030204 cardiovascular system & hematologyCoronary Angiography03 medical and health sciences0302 clinical medicinePercutaneous Coronary InterventionRisk FactorsInternal medicineCause of DeathmedicineRisk of mortalityHumans030212 general & internal medicineAcute Coronary SyndromeMortalityeducationAgededucation.field_of_studybusiness.industryIncidenceHazard ratioAcute kidney injuryPercutaneous coronary interventionAcute Kidney InjuryMiddle Agedmedicine.diseaseConfidence intervalCreatinineCardiologyST Elevation Myocardial InfarctionFemaleCardiology and Cardiovascular MedicinebusinessGlomerular Filtration RateThe American journal of cardiology
researchProduct

Search for neutrinoless double-beta decay ofMo100with the NEMO-3 detector

2014

We report the results of a search for the neutrinoless double-$\beta$ decay (0$\nu\beta\beta$) of $^{100}$Mo, using the NEMO-3 detector to reconstruct the full topology of the final state events. With an exposure of 34.7 kg.y, no evidence for the 0$\nu\beta\beta$ signal has been found, yielding a limit for the light Majorana neutrino mass mechanism of $T_{1/2}(0\nu\beta\beta)>1.1 \times 10^{24}$ years (90% C.L.) once both statistical and systematic uncertainties are taken into account. Depending on the Nuclear Matrix Elements this corresponds to an upper limit on the Majorana effective neutrino mass of $ < 0.3-0.8$ eV (90% C.L.). Constraints on other lepton number violating mechanisms of 0$…

PhysicsNuclear and High Energy PhysicsParticle physics010308 nuclear & particles physicsElectron01 natural sciencesBeta decayLepton numberNuclear physicsMAJORANADouble beta decay0103 physical sciencesBeta (velocity)Neutrino010306 general physicsEnergy (signal processing)Physical Review D
researchProduct

Final results on $${}^\mathbf{82 }{\hbox {Se}}$$ 82Se double beta decay to the ground state of $${}^\mathbf{82 }{\hbox {Kr}}$$ 82Kr from the NEMO-3 e…

2018

Using data from the NEMO-3 experiment, we have measured the two-neutrino double beta decay ($$2\nu \beta \beta $$ 2νββ ) half-life of $$^{82}$$ 82 Se as $$T_{\smash {1/2}}^{2\nu } \!=\! \left[ 9.39 \pm 0.17\left( \text{ stat }\right) \pm 0.58\left( \text{ syst }\right) \right] \times 10^{19}$$ T1/22ν=9.39±0.17stat±0.58syst×1019 y under the single-state dominance hypothesis for this nuclear transition. The corresponding nuclear matrix element is $$\left| M^{2\nu }\right| = 0.0498 \pm 0.0016$$ M2ν=0.0498±0.0016 . In addition, a search for neutrinoless double beta decay ($$0\nu \beta \beta $$ 0νββ ) using 0.93 kg of $$^{82}$$ 82 Se observed for a total of 5.25 y has been conducted and no evide…

European Physical Journal
researchProduct

Detailed studies of $$^{100}$$ 100 Mo two-neutrino double beta decay in NEMO-3

2019

The full data set of the NEMO-3 experiment has been used to measure the half-life of the two-neutrino double beta decay of $$^{100}$$ 100 Mo to the ground state of $$^{100}$$ 100 Ru, $$T_{1/2} = \left[ 6.81 \pm 0.01\,\left( \text{ stat }\right) ^{+0.38}_{-0.40}\,\left( \text{ syst }\right) \right] \times 10^{18}$$ T1/2=6.81±0.01stat-0.40+0.38syst×1018 year. The two-electron energy sum, single electron energy spectra and distribution of the angle between the electrons are presented with an unprecedented statistics of $$5\times 10^5$$ 5×105 events and a signal-to-background ratio of $$\sim $$ ∼ 80. Clear evidence for the Single State Dominance model is found for this nuclear transition. Limit…

European Physical Journal
researchProduct