0000000000162415
AUTHOR
B. Guillon
Measurement of the background in the NEMO 3 double beta decay experiment
In the double beta decay experiment NEMO 3 a precise knowledge of the background in the signal region is of outstanding importance. This article presents the methods used in NEMO 3 to evaluate the backgrounds resulting from most if not all possible origins. It also illustrates the power of the combined tracking-calorimetry technique used in the experiment.
Results of the search for neutrinoless double-βdecay inMo100with the NEMO-3 experiment
The NEMO-3 detector, which had been operating in the Modane Underground Laboratory from 2003 to 2010, was designed to search for neutrinoless double $\beta$ ($0\nu\beta\beta$) decay. We report final results of a search for $0\nu\beta\beta$ decays with $6.914$ kg of $^{100}$Mo using the entire NEMO-3 data set with a detector live time of $4.96$ yr, which corresponds to an exposure of 34.3 kg$\cdot$yr. We perform a detailed study of the expected background in the $0\nu\beta\beta$ signal region and find no evidence of $0\nu\beta\beta$ decays in the data. The level of observed background in the $0\nu\beta\beta$ signal region $[2.8-3.2]$ MeV is $0.44 \pm 0.13$ counts/yr/kg, and no events are obs…
Spectral modeling of scintillator for the NEMO-3 and SuperNEMO detectors
We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is improved if wavelength-dependent properties of the calorimeter are taken into account. In this article, we briefly describe our modeling approach and results of our studies.
An innovative lipid-lowering approach to enhance attainment of low-density lipoprotein cholesterol goals
Aims To improve attainment of LDL-cholesterol (LDL-c) targets, an expert group proposed an algorithm for lipid-lowering therapy during hospitalization for acute coronary syndrome and during follow-up. We aimed to assess adherence to this algorithm, and evaluate its impact on LDL-c levels and on attainment of therapeutic LDL-c targets in a population of post-acute coronary syndrome patients. Methods and results Prospective, observational study including patients admitted for acute coronary syndrome between February 2017 and September 2018. Patients admitted without statins or ezetimibe were considered ‘naïve’. Baseline LDL-c was admission LDL-c in naïve patients, and for those taking lipid-…
Measurement of the two neutrino double beta decay half-life of Zr-96 with the NEMO-3 detector
Using 9.4 g of Zr-96 and 1221 days of data from the NEMO-3 detector corresponding to 0.031 kg yr, the obtained 2vbb decay half-life measurement is [2.35 +/- 0.14(stat) +/- 0.16(syst)] x 10^19 yr. Different characteristics of the final state electrons have been studied, such as the energy sum, individual electron energy, and angular distribution. The 2v nuclear matrix element is extracted using the measured 2vbb half-life and is 0.049 +/- 0.002. Constraints on 0vbb decay have also been set.
Final results on $${}^\mathbf{82 }{\hbox {Se}}$$ 82Se double beta decay to the ground state of $${}^\mathbf{82 }{\hbox {Kr}}$$ 82Kr from the NEMO-3 experiment
Using data from the NEMO-3 experiment, we have measured the two-neutrino double beta decay ($$2\nu \beta \beta $$ 2νββ ) half-life of $$^{82}$$ 82 Se as $$T_{\smash {1/2}}^{2\nu } \!=\! \left[ 9.39 \pm 0.17\left( \text{ stat }\right) \pm 0.58\left( \text{ syst }\right) \right] \times 10^{19}$$ T1/22ν=9.39±0.17stat±0.58syst×1019 y under the single-state dominance hypothesis for this nuclear transition. The corresponding nuclear matrix element is $$\left| M^{2\nu }\right| = 0.0498 \pm 0.0016$$ M2ν=0.0498±0.0016 . In addition, a search for neutrinoless double beta decay ($$0\nu \beta \beta $$ 0νββ ) using 0.93 kg of $$^{82}$$ 82 Se observed for a total of 5.25 y has been conducted and no evide…
Outcomes after extracorporeal membrane oxygenation for the treatment of high-risk pulmonary embolism: a multicentre series of 52 cases
International audience; Aims The role of extracorporeal membrane oxygenation (ECMO) remains ill defined in pulmonary embolism (PE). We investigated outcomes in patients with high-risk PE undergoing ECMO according to initial therapeutic strategy. Methods and results From 01 January 2014 to 31 December 2015, 180 patients from 13 Departments in nine centres with high-risk PE were retrospectively included. Among those undergoing ECMO, we compared characteristics and outcomes according to adjunctive treatment strategy (systemic thrombolysis, surgical embolectomy, or no reperfusion therapy). Primary outcome was all-cause 30-day mortality. Secondary outcome was 90-day major bleeding. One hundred a…
Detailed studies of $$^{100}$$ 100 Mo two-neutrino double beta decay in NEMO-3
The full data set of the NEMO-3 experiment has been used to measure the half-life of the two-neutrino double beta decay of $$^{100}$$ 100 Mo to the ground state of $$^{100}$$ 100 Ru, $$T_{1/2} = \left[ 6.81 \pm 0.01\,\left( \text{ stat }\right) ^{+0.38}_{-0.40}\,\left( \text{ syst }\right) \right] \times 10^{18}$$ T1/2=6.81±0.01stat-0.40+0.38syst×1018 year. The two-electron energy sum, single electron energy spectra and distribution of the angle between the electrons are presented with an unprecedented statistics of $$5\times 10^5$$ 5×105 events and a signal-to-background ratio of $$\sim $$ ∼ 80. Clear evidence for the Single State Dominance model is found for this nuclear transition. Limit…
Measurement of theββDecay Half-Life ofTe130with the NEMO-3 Detector
This Letter reports results from the NEMO-3 experiment based on an exposure of 1275 days with 661g of 130Te in the form of enriched and natural tellurium foils. With this data set the double beta decay rate of 130Te is found to be non-zero with a significance of 7.7 standard deviations and the half-life is measured to be T1/2 = (7.0 +/- 0.9(stat) +/- 1.1(syst)) x 10^{20} yr. This represents the most precise measurement of this half-life yet published and the first real-time observation of this decay.
Detailed studies of $^{100}$Mo two-neutrino double beta decay in NEMO-3
The full data set of the NEMO-3 experiment has been used to measure the half-life of the two-neutrino double beta decay of $^{100}$Mo to the ground state of $^{100}$Ru, $T_{1/2} = \left[ 6.81 \pm 0.01\,\left(\mbox{stat}\right) ^{+0.38}_{-0.40}\,\left(\mbox{syst}\right) \right] \times10^{18}$ y. The two-electron energy sum, single electron energy spectra and distribution of the angle between the electrons are presented with an unprecedented statistics of $5\times10^5$ events and a signal-to-background ratio of ~80. Clear evidence for the Single State Dominance model is found for this nuclear transition. Limits on Majoron emitting neutrinoless double beta decay modes with spectral indices of …
To assess hemodynamic disturbances to the ostia of the renal arteries generated by the implantation of EVAR with a suprarenal fixation
Abstract Introduction: The treatment of abdominal aortic aneurysm (AAA) is increasingly performed via endovascular aneurysm repair (EVAR). Different types of fixation are possible with EVAR, i.e., below (infrarenal fixation) or above (suprarenal fixation) the renal arteries. Hemodynamic alterations in renal arterial flow with suprarenal (SR) fixation remain to be demonstrated. The IFIXEAR (Impact of Supra-renal Fixation of EVAR on Hemodynamics of Renal Arteries) study is designed to assess the hemodynamic effects at the ostia of at least 1 renal artery, generated immediately post-surgery by the implantation of an aortic stent with SR fixation. Methods: IFIXEAR is a prospective, 2 center stu…
Incidence, Predictors, and Impact on Six-Month Mortality of Three Different Definitions of Contrast-Induced Acute Kidney Injury After Coronary Angiography.
We assessed incidence, predictors, and impact on 6-month mortality of contrast-induced acute kidney injury (CI-AKI) after coronary angiography with or without percutaneous coronary intervention in patients with acute coronary syndrome (ACS), according to 3 different CI-AKI definitions. Serum creatinine (sCr) was assessed at baseline and 48 to 72 hours after procedure to classify patients into 3 CI-AKI groups: Group 1: increase in sCR ≥25% over baseline but absolute increase 25% in the remaining 844 (84.2%). CI-AKI was significantly associated with 6-month all-cause mortality using the definitions for Group 2 (hazard ratio 3.1, 95% confidence interval [CI] 1.5 to 6.6, p = 0.002) and Group 3 …
Search for neutrinoless double-beta decay ofMo100with the NEMO-3 detector
We report the results of a search for the neutrinoless double-$\beta$ decay (0$\nu\beta\beta$) of $^{100}$Mo, using the NEMO-3 detector to reconstruct the full topology of the final state events. With an exposure of 34.7 kg.y, no evidence for the 0$\nu\beta\beta$ signal has been found, yielding a limit for the light Majorana neutrino mass mechanism of $T_{1/2}(0\nu\beta\beta)>1.1 \times 10^{24}$ years (90% C.L.) once both statistical and systematic uncertainties are taken into account. Depending on the Nuclear Matrix Elements this corresponds to an upper limit on the Majorana effective neutrino mass of $ < 0.3-0.8$ eV (90% C.L.). Constraints on other lepton number violating mechanisms of 0$…