0000000000163510
AUTHOR
M. N. Erduran
Structure of the As, Ge, Ga nuclei
Abstract The level structures of the N = 50 83As, 82Ge, and 81Ga isotones have been investigated by means of multi-nucleon transfer reactions. A first experiment was performed with the CLARA–PRISMA setup to identify these nuclei. A second experiment was carried out with the GASP array in order to deduce the γ-ray coincidence information. The results obtained on the high-spin states of such nuclei are used to test the stability of the N = 50 shell closure in the region of 78Ni ( Z = 28 ). The comparison of the experimental level schemes with the shell-model calculations yields an N = 50 energy gap value of 4.7(3) MeV at Z = 28 . This value, in a good agreement with the prediction of the fini…
Neutron detection and γ-ray suppression using artificial neural networks with the liquid scintillators BC-501A and BC-537
Abstract In this work we present a comparison between the two liquid scintillators BC-501A and BC-537 in terms of their performance regarding the pulse-shape discrimination between neutrons and γ rays. Special emphasis is put on the application of artificial neural networks . The results show a systematically higher γ -ray rejection ratio for BC-501A compared to BC-537 applying the commonly used charge comparison method. Using the artificial neural network approach the discrimination quality was improved to more than 95% rejection efficiency of γ rays over the energy range 150 to 1000 keV for both BC-501A and BC-537. However, due to the larger light output of BC-501A compared to BC-537, neu…
Monte Carlo simulation of a single detector unit for the neutron detector array NEDA
WOS: 000301813500009
Lifetime measurements in neutron-rich63,65Co isotopes using the AGATA demonstrator
Lifetimes of the low-lying (11/2-) states in 63,65Co have been measured employing the recoil distance doppler shift method (RDDS) with the AGATA γ-ray array and the PRISMA mass spectrometer. These nuclei were populated via a multinucleon transfer reaction by bombarding a 238U target with a beam of 64Ni. The experimental B(E2) reduced transition probabilities for 63,65Co are well reproduced by large-scale shell-model calculations that predict a constant trend of the B(E2) values up to the N=40 67Co isotope
Digital Front-End Electronics for the Neutron Detector NEDA
19th Real Time Conference (RT) -- MAY 26-30, 2014 -- Nara, JAPAN
A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors
19th Real Time Conference (RT) -- MAY 26-30, 2014 -- Nara, JAPAN WOS: 000356458000028 This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected …
Digital pulse-timing technique for the neutron detector array NEDA
WOS: 000348040900011
Pulse pile-up identification and reconstruction for liquid scintillator based neutron detectors
WOS: 000433206800010 The issue of pulse pile-up is frequently encountered in nuclear experiments involving high counting rates, which will distort the pulse shapes and the energy spectra. A digital method of off-line processing of pile-up pulses is presented. The pile-up pulses were firstly identified by detecting the downward-going zero-crossings in the first-order derivative of the original signal, and then the constituent pulses were reconstructed based on comparing the pile-up pulse with four models that are generated by combining pairs of neutron and.. standard pulses together with a controllable time interval. The accuracy of this method in resolving the pile-up events was investigate…
Test of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)
WOS: 000344994600012
AGATA-Advanced GAmma Tracking Array
WOS: 000300864200005