Intraoral Cameras as a Computer-Aided Diagnosis Tool for Root Canal Orifices

2011

The aim of this study was to evaluate the diagnostic advantage of a new software tool in combination with an intraoral camera for automatic detection of root canal orifices in life videos via the access cavity of extracted human molars. The performance of a predoctoral dental student analyzing the images of the camera (without automatic detection) was compared with that of an experienced observer. Sensitivity and confidence intervals were provided and compared with histological slices of 200 teeth used for evaluation. The software's sensitivity for detection of root canal orifices was 0.957 (95 percent confidence interval: 0.936 to 0.972). The sensitivity for the observer was 0.906 (95 perc…

Computer sciencebusiness.industryRoot canalSoftware toolDentistryGeneral MedicineConfidence intervalSoftwaremedicine.anatomical_structureMesiobuccal rootComputer-aided diagnosisIntraoral cameramedicinebusinessSensitivity (electronics)Journal of Dental Education
researchProduct

Recognition of root canal orifices at a distance – a preliminary study of teledentistry

2011

The remote recognition of root canal orifices was tested on 50 images of endodontically accessed teeth acquired with an intra-oral camera. The images were stored on a laptop computer and were presented to 20 observers who marked the visible canal orifices using software which stored the canal locations in standard files. The marked positions were verified on histological slices. In 87% of the cases, the canal locations were marked correctly. Inter-observer reliability depended on the location of the reviewed root canal (kappa = 0.44–0.77). The detection rate was related to the professional experience of the observers. The maximum proportion of accurate detections was found for the observer…

AdultObserver Variationbusiness.industryRoot canalDentistryHealth InformaticsMiddle AgedMolarTelemedicinemedicine.anatomical_structureTooth DiseasesDentistryHumansMedicineClinical CompetenceDental Pulp CavityDetection ratebusinessTeledentistryAgedJournal of Telemedicine and Telecare
researchProduct

The Treatment of Anterior Dental Trauma

2011

Anterior dental trauma is a common injury pattern of the dentoalveolar system in which appropriate first aid is important. When children and adolescents suffer an anterior dental trauma, the challenge is to preserve the tooth in this esthetically important area and minimize subsequent damage. Lack of treatment or improper treatment can lead to a lifelong need for dental care. There are many causes of anterior dental trauma. At the age of one and two years, it is mainly caused by falls when learning to walk. At preschool age, between two and six years, many such injuries are caused by falls resulting from lack of attention when engaging in physical play. The highest incidence of anterior den…

MaleAdolescentDentistryTooth FractureReview ArticleTooth ReplantationTooth Fracturesstomatognathic systemGermanyConcussionRadiography PanoramicDeciduous teethmedicineFirst AidHumansChildRetrospective StudiesDental traumabusiness.industryGeneral Medicinemedicine.diseaseTooth AvulsionIncisorstomatognathic diseasesmedicine.anatomical_structureSocial deprivationCross-Sectional StudiesFemaleTooth ReplantationTissue PreservationTooth AvulsionbusinessFirst aid
researchProduct

Alignment of cone beam computed tomography data using intra-oral fiducial markers.

2009

This article illustrates a new method to align and merge two partially overlapping volumes each of them generated by cone beam computed tomography (CBCT). The aggregate volume covers a larger area of investigation and is determined by localizing one fixed LEGO brick in both of the primal volumes. Based on the LEGO brick an approximate registration of the volumes is determined. Afterwards we improve the transformation by minimizing the difference in overlapping space. In this paper we present a method which automates these two steps and provides an aligned volume.

Cone beam computed tomographyMouthRadiological and Ultrasound Technologybusiness.industryComputer sciencePhantoms ImagingHealth InformaticsRadiography Dental DigitalCone-Beam Computed TomographyComputer Graphics and Computer-Aided DesignComputer Science::Computers and SocietyOpticsJawIntra oralHumansRadiology Nuclear Medicine and imagingComputer visionComputer Vision and Pattern RecognitionArtificial intelligencebusinessFiducial markerMerge (version control)Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
researchProduct

Evaluation of ultrasound transmission velocity and 3-dimensional radiology in different bone types for dental implantology: a comparative ex vivo stu…

2013

Objective To evaluate ultrasound transmission velocity (UTV) for assessment of mechanical bone quality, an ex vivo comparison of different bone types measured with UTV, 2-dimensional (2D) histomorphometry and with 3-dimensional (3D) radiology (cone-beam computerized tomography [CBCT], computerized microtomography [μCT]) was conducted. Study Design Clinical cortical, cancellous, and mixed bone (each n = 6) was measured via UTV (m/s), CBCT (white pixel/black pixel ratio [WP/BP]), μCT (bone volume/total volume [μBV/TV]), and histomorphometry (bone volume/total volume [hBV/TV]). UTV values were correlated with 2D-histomorphometry and 3D-radiologic results. Results For the cortical, cancellous, …

Malemedicine.medical_specialtyCone beam computed tomographyX-ray microtomographyBone densitySwineTransducersRibsBone and BonesPathology and Forensic MedicineIliumDental implantologyImaging Three-DimensionalBone DensitymedicineImage Processing Computer-AssistedAnimalsRadiology Nuclear Medicine and imagingDentistry (miscellaneous)UltrasonicsUltrasonographybusiness.industryUltrasoundDental Implantation EndosseousX-Ray MicrotomographyCone-Beam Computed TomographySurgeryRadiologyTomographyOral SurgerybusinessBone volumeEx vivoOral surgery, oral medicine, oral pathology and oral radiology
researchProduct

Advantages of fitting contrast curves using logistic function: a technical note.

2013

Objective The aim of this article is to demonstrate how the contrast properties of an imaging system can be ideally fitted with the use of stripe patterns and the logistic function. Study Design Stripe patterns with defined amounts of line pairs (lp/mm) per mm (10-20 lp/mm) were recorded with the use of digital photostimulable storage phosphor. Scan data and normalized image data were analyzed with the use of ImageJ and MatLab to calculate different contrast curves. Results For original scan data, the goodness of fit was 0.0000019 (sum of squared error [SSE]). The R-square was 0.9998. For normalized data the goodness of fit was 0.0007 (SSE) and the R-square 0.998. An amount of 50% contrast …

Mean squared errorComputer scienceContrast (statistics)Image processingRadiography Dental DigitalPathology and Forensic MedicineRadiographic Image EnhancementLogistic ModelsGoodness of fitStatisticsLine (geometry)Image Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingDentistry (miscellaneous)SurgeryRadiographic Image EnhancementX-Ray Intensifying ScreensOral SurgeryLogistic functionMATLABcomputerAlgorithmAlgorithmscomputer.programming_languageOral surgery, oral medicine, oral pathology and oral radiology
researchProduct

Coincidence of mandibular fractures with isolated posterior maxillary sinus fractures

2017

Background/aim There are no data available to show whether there is a relationship between mandibular fractures and isolated fractures of the posterior and/or lateral walls of the maxillary sinus. The aim of this study was to determine whether there is a coincidence between these fracture patterns. Methods Four hundred large volume cone beam computed tomography scans (CBCT) of patients with a fracture of the mandible between 2008 and 2013 were analyzed retrospectively. Patients with multiple midfacial fractures were excluded. The radiographic findings were correlated with epidemiological and clinical data of the patients such as gender, age, treatment methods, or complications. Results The …

AdultMaleCone beam computed tomographyMaxillary sinusRadiographyFracture siteMaxillary FracturesCondyle03 medical and health sciences0302 clinical medicineGermanyMandibular FracturesHumansMedicine030223 otorhinolaryngologyRetrospective StudiesOrthodonticsbusiness.industryMandibleTreatment method030206 dentistryCone-Beam Computed TomographyMaxillary Sinusmedicine.anatomical_structureFracture (geology)FemaleOral SurgerybusinessDental Traumatology
researchProduct

Recognition of Root Canal Orifices in Video Sequences as a Future Support System During Endodontic Treatment

2009

Abstract Introduction The objective of this study was to show the practical application of computer-aided techniques for detecting root canal orifices through the access cavity using a video camera mounted on a microscope. Methods A minimum distance classification image recognition algorithm was tested in an in vitro study to assess the possibilities of computer-aided recognition of root canal orifices. A Motic DM143 digital stereo microscope (Motic Germany GmbH, Wetzlar, Germany) was used because it includes a video camera that can be connected via USB1.1 to any computer. Results The newly developed software is capable of communicating with a video camera and can automatically detect the r…

AdultMicroscopeComputer scienceRoot canalVideo RecordingComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONDentistryImage processingVideo cameraSensitivity and SpecificityPattern Recognition Automatedlaw.inventionSoftwarelawStereo microscopeImage Processing Computer-AssistedmedicineHumansBicuspidFalse Positive ReactionsComputer visionGeneral DentistryAgedMicroscopybusiness.industryMiddle AgedMolarmedicine.anatomical_structureTherapy Computer-AssistedPattern recognition (psychology)Artificial intelligenceDental Pulp CavitybusinessAlgorithmsRoot Canal PreparationSoftwareTest dataJournal of Endodontics
researchProduct

Promotion of osteogenic cell response using quasicovalent immobilized fibronectin on titanium surfaces: introduction of a novel biomimetic layer syst…

2012

Purpose Despite the undeniable potential of cell adhesion molecules such as fibronectin to support osteogenic cell responses and consecutive dental implant healing, the most beneficial mode of application onto titanium implant surfaces still requires investigation. Unspecific fibronectin adsorption on titanium dioxide (TiO2) surfaces can result in low-loading, high-desorption rates and protein–metal interactions with impaired biologic activity. The aim of the present study was to monitor the osteogenic cell responses (cell adhesion, proliferation, and differentiation) specifically to fibronectin biofunctionalized TiO2. Materials and Methods An innovative biomimetic streptavidin-biotin layer…

Time FactorsCellular differentiationOsteocalcinCell Culture TechniquesBiotinBiocompatible MaterialsCore Binding Factor Alpha 1 SubunitCell LineCyclin D1Biomimetic MaterialsOsteogenesisCell AdhesionMedicineHumansCyclin D1Cell adhesionCell ProliferationTitaniumOsteoblastsbiologyCell adhesion moleculebusiness.industryIntegrin beta1Cell DifferentiationAdhesionSilanesAlkaline PhosphataseFibronectinsFibronectinImmobilized ProteinsPhenotypeOtorhinolaryngologyBiotinylationVitamin B Complexbiology.proteinBiophysicsAlkaline phosphataseSurgeryAdsorptionStreptavidinOral SurgerybusinessJournal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons
researchProduct

Software for automated application of a reference-based method fora posterioridetermination of the effective radiographic imaging geometry

2005

Objectives: Presentation and validation of software developed for automated and accurate application of a reference-based algorithm (reference sphere method: RSM) inferring the effective imaging geometry from quantitative radiographic image analysis. Methods: The software uses modern pattern recognition and computer vision algorithms adapted for the particular application of automated detection of the reference sphere shadows (ellipses) with subpixel accuracy. It applies the RSM algorithm to the shadows detected, thereby providing threedimensional Cartesian coordinates of the spheres. If the three sphere centres do not lie on one line, they uniquely determine the imaging geometry. Accuracy …

Image formationSoftware ValidationImage registrationGeometryMandibleEllipsePattern Recognition Automatedlaw.inventionImaging Three-DimensionalSoftwareArtificial IntelligenceSoftware DesignlawImage Processing Computer-AssistedHumansSuperimpositionRadiology Nuclear Medicine and imagingCartesian coordinate systemGeneral DentistryMathematicsbusiness.industryRadiography Dental DigitalGeneral MedicineSubpixel renderingOtorhinolaryngologyCalibrationLine (geometry)businessAlgorithmsSoftwareDentomaxillofacial Radiology
researchProduct

Comparison of 4% articaine with epinephrine (1:100,000) and without epinephrine in inferior alveolar block for tooth extraction: double-blind randomi…

2011

The purpose of this clinical prospective, randomized, double-blind study was to compare the anesthetic efficacy of 4% articaine with epinephrine (1:100,000) and without epinephrine in inferior alveolar nerve block anesthesia for extractions of mandibular teeth.Eighty-eight patients received intraoral inferior alveolar nerve blocks using 4% articaine with 1:100,000 epinephrine (n = 41; group 1) or without epinephrine (n = 47; group 2) for extractions of mandibular teeth. The primary objectives were differences in onset as well as in length of soft tissue anesthesia. The amount of anesthetic solution, need of a second injection, pain while injecting, pain during treatment, postoperative pain,…

AdultMalemedicine.medical_specialtyAdolescentEpinephrineAnesthesia DentalMandibular NerveOperative TimeMandibular nerveCarticaineAnesthetic AgentInferior alveolar nerveArticainePathology and Forensic Medicinelaw.inventionYoung AdultCarticaineDouble-Blind MethodRandomized controlled triallawHumansVasoconstrictor AgentsMedicineRadiology Nuclear Medicine and imagingDentistry (miscellaneous)Prospective StudiesAnesthetics LocalAgedAged 80 and overPain PostoperativeChi-Square Distributionbusiness.industryNerve BlockMiddle AgedSurgeryEpinephrineAnesthesiaTooth ExtractionAnestheticFemaleSurgeryOral Surgerybusinessmedicine.drugOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
researchProduct

Early root surface colonization by human periodontal ligament fibroblasts following treatment with different biomaterials

2013

The present in-vitro study examined the effects of different biomaterials on early root surface colonization by human periodontal ligament (PDL) fibroblasts using confocal-laser-scanning-microscopy (CLSM).Fifteen periodontally-diseased teeth were extracted, treated with scaling/root planing and longitudinally cut to obtain 30 root fragments. Fragments were treated either with 24% EDTA following application of enamel matrix derivative (EMD), 24% EDTA or EMD only, nanocrystalline hydroxyapatite (NHA) paste or oily calcium hydroxide suspension (OCHS) for 1 h each. The analogue untreated root specimens served as controls. Root fragments were incubated with human PDL fibroblasts and cellular pro…

Microscopy ConfocalRoot surfaceMorphology (linguistics)Calcium hydroxidePeriodontal LigamentChemistrybusiness.industryDentistryRoot planingBiocompatible MaterialsGeneral MedicineFibroblastsMolecular biologychemistry.chemical_compoundTreatment modalityEnamel matrix derivativeHumansPeriodontal fiberColonizationTooth RootbusinessGeneral DentistryActa Odontologica Scandinavica
researchProduct

Fast algorithm for detection of reference spheres in digital panoramic radiography.

2009

In this paper, an algorithm for detection of reference spheres from digital panoramic radiographic images is presented. The proposed algorithm was tested on a database of 107 digital panoramic radiographic images which were used for dental diagnostics. Results show that the proposed method exhibits for detection of reference spheres, a sensitivity of 97.33% and specificity of 93.85%. Performance time differed between 0.55 and 2.36s depending on image size. The aim of this work was to provide a fast ellipse detection algorithm to reduce measuring time on preoperative implant planning by lowering the computational cost.

business.industryComputer scienceRadiographyHealth InformaticsRadiography Dental DigitalEllipseFast algorithmSensitivity and SpecificityComputer Science ApplicationsDental ImplantationSurgery Computer-AssistedPattern recognition (psychology)HumansComputer visionSPHERESArtificial intelligenceSensitivity (control systems)Diagnosis Computer-AssistedbusinessImage resolutionAlgorithmsSoftwareComputers in biology and medicine
researchProduct