0000000000170481
AUTHOR
Dan Brüllmann
Intraoral Cameras as a Computer-Aided Diagnosis Tool for Root Canal Orifices
The aim of this study was to evaluate the diagnostic advantage of a new software tool in combination with an intraoral camera for automatic detection of root canal orifices in life videos via the access cavity of extracted human molars. The performance of a predoctoral dental student analyzing the images of the camera (without automatic detection) was compared with that of an experienced observer. Sensitivity and confidence intervals were provided and compared with histological slices of 200 teeth used for evaluation. The software's sensitivity for detection of root canal orifices was 0.957 (95 percent confidence interval: 0.936 to 0.972). The sensitivity for the observer was 0.906 (95 perc…
Recognition of root canal orifices at a distance – a preliminary study of teledentistry
The remote recognition of root canal orifices was tested on 50 images of endodontically accessed teeth acquired with an intra-oral camera. The images were stored on a laptop computer and were presented to 20 observers who marked the visible canal orifices using software which stored the canal locations in standard files. The marked positions were verified on histological slices. In 87% of the cases, the canal locations were marked correctly. Inter-observer reliability depended on the location of the reviewed root canal (kappa = 0.44–0.77). The detection rate was related to the professional experience of the observers. The maximum proportion of accurate detections was found for the observer…
The Treatment of Anterior Dental Trauma
Anterior dental trauma is a common injury pattern of the dentoalveolar system in which appropriate first aid is important. When children and adolescents suffer an anterior dental trauma, the challenge is to preserve the tooth in this esthetically important area and minimize subsequent damage. Lack of treatment or improper treatment can lead to a lifelong need for dental care. There are many causes of anterior dental trauma. At the age of one and two years, it is mainly caused by falls when learning to walk. At preschool age, between two and six years, many such injuries are caused by falls resulting from lack of attention when engaging in physical play. The highest incidence of anterior den…
Alignment of cone beam computed tomography data using intra-oral fiducial markers.
This article illustrates a new method to align and merge two partially overlapping volumes each of them generated by cone beam computed tomography (CBCT). The aggregate volume covers a larger area of investigation and is determined by localizing one fixed LEGO brick in both of the primal volumes. Based on the LEGO brick an approximate registration of the volumes is determined. Afterwards we improve the transformation by minimizing the difference in overlapping space. In this paper we present a method which automates these two steps and provides an aligned volume.
Evaluation of ultrasound transmission velocity and 3-dimensional radiology in different bone types for dental implantology: a comparative ex vivo study.
Objective To evaluate ultrasound transmission velocity (UTV) for assessment of mechanical bone quality, an ex vivo comparison of different bone types measured with UTV, 2-dimensional (2D) histomorphometry and with 3-dimensional (3D) radiology (cone-beam computerized tomography [CBCT], computerized microtomography [μCT]) was conducted. Study Design Clinical cortical, cancellous, and mixed bone (each n = 6) was measured via UTV (m/s), CBCT (white pixel/black pixel ratio [WP/BP]), μCT (bone volume/total volume [μBV/TV]), and histomorphometry (bone volume/total volume [hBV/TV]). UTV values were correlated with 2D-histomorphometry and 3D-radiologic results. Results For the cortical, cancellous, …
Advantages of fitting contrast curves using logistic function: a technical note.
Objective The aim of this article is to demonstrate how the contrast properties of an imaging system can be ideally fitted with the use of stripe patterns and the logistic function. Study Design Stripe patterns with defined amounts of line pairs (lp/mm) per mm (10-20 lp/mm) were recorded with the use of digital photostimulable storage phosphor. Scan data and normalized image data were analyzed with the use of ImageJ and MatLab to calculate different contrast curves. Results For original scan data, the goodness of fit was 0.0000019 (sum of squared error [SSE]). The R-square was 0.9998. For normalized data the goodness of fit was 0.0007 (SSE) and the R-square 0.998. An amount of 50% contrast …
Coincidence of mandibular fractures with isolated posterior maxillary sinus fractures
Background/aim There are no data available to show whether there is a relationship between mandibular fractures and isolated fractures of the posterior and/or lateral walls of the maxillary sinus. The aim of this study was to determine whether there is a coincidence between these fracture patterns. Methods Four hundred large volume cone beam computed tomography scans (CBCT) of patients with a fracture of the mandible between 2008 and 2013 were analyzed retrospectively. Patients with multiple midfacial fractures were excluded. The radiographic findings were correlated with epidemiological and clinical data of the patients such as gender, age, treatment methods, or complications. Results The …
Recognition of Root Canal Orifices in Video Sequences as a Future Support System During Endodontic Treatment
Abstract Introduction The objective of this study was to show the practical application of computer-aided techniques for detecting root canal orifices through the access cavity using a video camera mounted on a microscope. Methods A minimum distance classification image recognition algorithm was tested in an in vitro study to assess the possibilities of computer-aided recognition of root canal orifices. A Motic DM143 digital stereo microscope (Motic Germany GmbH, Wetzlar, Germany) was used because it includes a video camera that can be connected via USB1.1 to any computer. Results The newly developed software is capable of communicating with a video camera and can automatically detect the r…
Promotion of osteogenic cell response using quasicovalent immobilized fibronectin on titanium surfaces: introduction of a novel biomimetic layer system.
Purpose Despite the undeniable potential of cell adhesion molecules such as fibronectin to support osteogenic cell responses and consecutive dental implant healing, the most beneficial mode of application onto titanium implant surfaces still requires investigation. Unspecific fibronectin adsorption on titanium dioxide (TiO2) surfaces can result in low-loading, high-desorption rates and protein–metal interactions with impaired biologic activity. The aim of the present study was to monitor the osteogenic cell responses (cell adhesion, proliferation, and differentiation) specifically to fibronectin biofunctionalized TiO2. Materials and Methods An innovative biomimetic streptavidin-biotin layer…
Software for automated application of a reference-based method fora posterioridetermination of the effective radiographic imaging geometry
Objectives: Presentation and validation of software developed for automated and accurate application of a reference-based algorithm (reference sphere method: RSM) inferring the effective imaging geometry from quantitative radiographic image analysis. Methods: The software uses modern pattern recognition and computer vision algorithms adapted for the particular application of automated detection of the reference sphere shadows (ellipses) with subpixel accuracy. It applies the RSM algorithm to the shadows detected, thereby providing threedimensional Cartesian coordinates of the spheres. If the three sphere centres do not lie on one line, they uniquely determine the imaging geometry. Accuracy …
Comparison of 4% articaine with epinephrine (1:100,000) and without epinephrine in inferior alveolar block for tooth extraction: double-blind randomized clinical trial of anesthetic efficacy
The purpose of this clinical prospective, randomized, double-blind study was to compare the anesthetic efficacy of 4% articaine with epinephrine (1:100,000) and without epinephrine in inferior alveolar nerve block anesthesia for extractions of mandibular teeth.Eighty-eight patients received intraoral inferior alveolar nerve blocks using 4% articaine with 1:100,000 epinephrine (n = 41; group 1) or without epinephrine (n = 47; group 2) for extractions of mandibular teeth. The primary objectives were differences in onset as well as in length of soft tissue anesthesia. The amount of anesthetic solution, need of a second injection, pain while injecting, pain during treatment, postoperative pain,…
Early root surface colonization by human periodontal ligament fibroblasts following treatment with different biomaterials
The present in-vitro study examined the effects of different biomaterials on early root surface colonization by human periodontal ligament (PDL) fibroblasts using confocal-laser-scanning-microscopy (CLSM).Fifteen periodontally-diseased teeth were extracted, treated with scaling/root planing and longitudinally cut to obtain 30 root fragments. Fragments were treated either with 24% EDTA following application of enamel matrix derivative (EMD), 24% EDTA or EMD only, nanocrystalline hydroxyapatite (NHA) paste or oily calcium hydroxide suspension (OCHS) for 1 h each. The analogue untreated root specimens served as controls. Root fragments were incubated with human PDL fibroblasts and cellular pro…
Fast algorithm for detection of reference spheres in digital panoramic radiography.
In this paper, an algorithm for detection of reference spheres from digital panoramic radiographic images is presented. The proposed algorithm was tested on a database of 107 digital panoramic radiographic images which were used for dental diagnostics. Results show that the proposed method exhibits for detection of reference spheres, a sensitivity of 97.33% and specificity of 93.85%. Performance time differed between 0.55 and 2.36s depending on image size. The aim of this work was to provide a fast ellipse detection algorithm to reduce measuring time on preoperative implant planning by lowering the computational cost.