A New Calibration Method for the Accurate Determination of Ethylene Content in Ethylene-Propylene Copolymers by CRYSTEX-IR

Summary: CRYSTEX is a fully automated instrument for the determination of Xylene Solubles in polypropylene and ethylene-propylene copolymers, providing an excellent correlation with gravimetric methods. The instrument can be equipped with a dual band infrared (IR) detector to quantify the ethylene weight percentage (C2%) in the amorphous fraction, and in the whole polymer sample. In this work, a new approach based on multiple linear regression (MLR) models is presented, which makes use of two independent IR absorbance signals acquired simultaneously by the detector. A compromise model to predict directly C2% is proposed, which balances good accuracy and reduced experimental effort. MLR mode…

research product

Finding the best separation in situations of extremely low chromatographic resolution.

Abstract Samples with a large number of compounds or similarities in their structure and polarity may yield insufficient chromatographic resolution. In such cases, however, finding conditions where the largest number of compounds appears sufficiently resolved can be still worthwhile. A strategy is here reported that optimises the resolution level of chromatograms in cases where conventional global criteria, such as the worst resolved peak pair or the product of elementary resolutions, are not able to detect any separation, even when most peaks are baseline resolved. The strategy applies a function based on the number of “well resolved” peaks, which are those that exceed a given threshold of…

research product

A complementary mobile phase approach based on the peak count concept oriented to the full resolution of complex mixtures

Situations of minimal resolution are often found in liquid chromatography, when samples that contain a large number of compounds, or highly similar in terms of structure and/or polarity, are analysed. This makes full resolution with a single separation condition (e.g., mobile phase, gradient or column) unfeasible. In this work, the optimisation of the resolution of such samples in reversed-phase liquid chromatography is approached using two or more isocratic mobile phases with a complementary resolution behaviour (complementary mobile phases, CMPs). Each mobile phase is dedicated to the separation of a group of compounds. The CMPs are selected in such a way that, when the separation is cons…

research product

Filter-based infrared detectors for high temperature size exclusion chromatography analysis of polyolefins: calibration with a small number of standards and error analysis.

Infrared detection has been shown to be very appropriate for high temperature analysis of polyolefins. After some early reports in which dispersive or single-band filter-based detectors were applied, Fourier transform detectors have been described for this application, in order to improve the method sensitivity. Modern simple filter-based detectors prove, however, comparable sensitivity while providing a number of practical advantages when coupled to chromatographic systems: reduced cell volume, simplified hardware, continuous generation of absorbance chromatograms, as well as simpler data collection and processing. A practical method for calibration, using multiple-band signals obtained wi…