0000000000172282

AUTHOR

Rafael Arcesio Delgado-ruiz

Calculation of bone graft volume using 3D reconstruction system.

Objectives: To obtain bone ?bioreplicas? for determining precisely the amount of biomaterial required for bone regeneration procedure. Study design: A case-control comparison with a total sample size of 20 cases, 10 control and 10 test samples. ?Bioreplicas? were generated from helical CAT scans with 0.5 mm slices, without 3D reconstruction or image filters. Bone defects in premolar and molar areas were treated with titanium mesh and xenograft (MP3) combined with resorbable carriers. Time taken to carry out procedures with and without the use of ?bioreplicas? (in minutes), discrepancies between the grafts performed with and without ?bioreplicas? and bone defects (mm), and postoperative comp…

research product

Ultrastructural study by backscattered electron imaging and elemental microanalysis of biomaterial-to-bone interface and mineral degradation of bovine xenografts in maxillary sinus floor elevation.

Objectives The aim of this study was to perform an ultrastructural study of the bone-to-biomaterial interface and biomaterial mineral degradation in retrieved bone biopsies following maxillary sinus augmentation using bovine xenografts (Endobon®) in 15 clinical cases. Materials and methods Nine months after sinus lifting, bone cores were harvested from the maxillary sinus. The specimens were processed for observation under a scanning electron microscope with backscattered electron imaging (SEM-BSE). In addition, chemical analysis and elemental mapping of the mineral composition were generated using a microanalytical system based on energy-dispersive X-ray spectrometry (EDX). Results No clin…

research product

Evaluation of periimplant bone neoformation using different scanning electron microscope methods for measuring BIC. A dog study.

Objetives: The aim of this study was to determine which of three methods for measuring BIC (bone-to-implant contact), using vestibular and lingual scanning electron microscopy (SEM) for different implant systems at 15, 30 and 90 days post-surgery was the most precise. An elemental analysis with SEM was used to evaluate neoformed bone composition for three implant systems at the same study times. Material and Methods: 36 implants were placed in eighteen Beagle dogs mandible about one year old and weighing approximately 12-13 kg in order to evaluate bone apposition to three different implant surfaces. It was used the third and fourth premolar and first molar distal sockets in both quadrants o…

research product