0000000000180209

AUTHOR

M.j. Redondo

Solid-phase extraction on C18 in the trace determination of selected polychlorinated biphenyls in milk.

The utility of solid-phase extraction with octadecylsilica for determining fifteen polychlorinated biphenyl (PCB) congeners from milk samples was examined. Recoveries higher than 80% and relative standard deviations better than 10% were obtained for PCBs from different kinds of milk (whole, skimmed, 2%, powdered, breast and evaporated). A comparison with other procedures was made. The described method provides better detection limits than those attainable with the liquid-liquid extractions currently used as standard methods, when capillary gas-liquid chromatography is used for the final determination. A study of the separation was also performed using six different fused-silica capillary co…

research product

Toxicity assessment of pesticides using the microtox test: application to environmental samples.

research product

Matrix solid-phase dispersion extraction procedure for multiresidue pesticide analysis in oranges.

A multiresidue extraction method based on matrix solid-phase dispersion (MSPD) is optimized for the extraction and gas chromatographic screening of eighteen insecticides (aldrin, carbophenothion, captafol, chlorpyriphos, chlorfenvinphos, diazinon, dicofol, alpha-endosulfan, beta-endosulfan, ethion, fenitrothion, folpet, methidathion, malathion, methyl-azinphos, methyl-parathion, phosmet, and tetradifon) from oranges. After optimization of different parameters, such as type of solid phase used and the amount of solid phase or eluent, recoveries ranged from 67 to 102% with relative standard deviations ranging from 2 to 10%. The limits of detection, calculated as 3 times the baseline noise ran…

research product

Determination of abamectin in citrus fruits by liquid chromatography-electrospray ionization mass spectrometry.

Liquid chromatography coupled to electrospray mass spectrometry (LC-ES-MS) with positive ion detection was used to determine abamectin in oranges. MS conditions were optimized to achieve maximum sensitivity. The main ion for abamectin was [M+Na]+ at a fragmentor voltage of 180 V. Abundant structural information can be obtained at different fragmentor voltages. The detection limit for the standard solution was 12 pg injected, and good linearity and reproducibility were observed. Abamectin residues were extracted using matrix solid-phase dispersion. Orange samples were homogenized with C18 bonded silica placed onto a glass column and eluted with dichloromethane. Recoveries of the abamectin fr…

research product

Determination of pesticides in soil samples by solid phase extraction disks

A systematic study comparing the methodology and analytical results obtained in an investigation of seven pesticide residues (Molinate, Atrazine, Carbofuran, Pirimicarb, Prometryn, Malathion and Tetrachlorvinphos) in soil samples is reported. Solid-phase extraction (SPE) using glass columns and 47 mm disks of octyl and octadecyl-bonded silica was used in the pesticide analysis. The best extraction efficiency and clearest extracts are obtained with C8 disks. The analyses were carried out by capillary gas chromatography with nitrogen and phosphorus detection. Recovery experiments were performed at ppb levels in spiked soil samples. The average recoveries of the compounds were 53–77%. Detectio…

research product

Comparison of various liquid chromatographic methods for the analysis of avermectin residues in citrus fruits.

Abstract Various liquid chromatographic (LC) techniques for analyzing avermectin (Abamectin) were compared after extraction of residues from citrus fruit samples by matrix solid-phase dispersion (MSPD). LC with UV and fluorescence detection were used as also was LC coupled to the mass spectrometer by an electrospray interface. The results obtained by the three methods were compared in terms of sensitivity and selectivity. The combination of MSPD extraction and LC with fluorescence detection have made it possible to quantify 0.5 μg kg −1 of Abamectin in 0.5 g of orange sample, with an overall average recovery of 94%. The procedure provides a simple and sensitive method for monitoring Abamect…

research product

Matrix solid-phase dispersion microextraction and determination by high-performance liquid chromatography with UV detection of pesticide residues in citrus fruit.

A multiresidue method based on matrix solid-phase dispersion (MSPD) microextraction was studied to determine the carbamate, benfuracarb, and urea insecticides, diflubenzuron, flufenoxuron hexaflumuron and hexythiazox, used in control of citrus pests. Optimisation of different parameters, such as the type of solid support for matrix dispersion, elution solvents and the clean-up step were carried out. The method used 0.5 g of orange sample, C8 bonded silica as MSPD sorbent and dichloromethane as eluting solvent. Recoveries, at spiked concentrations below the maximum residue levels established by Spanish Government, were between 74 and 84% with relative standard deviations ranging from 2 to 4%…

research product

Solid-phase extraction disks for determining pesticides from soil leachates

Abstract Analytical techniques are essential for identifying and quantifying the chemicals present in environmental samples. A method for extracting pesticides from soil leachates was developed. The proposed method is based on solid-phase extraction and uses 47-mm disks of octyl-bonded silica. Analysis was carried out by gas chromatography with nitrogen–phosphorus and electron-capture detectors. Several factors that can provide better pesticide recoveries with this extraction method are discussed. These factors are: the kind and percentage of organic solvent used in the extraction procedure, the volume and the ionic strength (adding 15% of NaCl) of the aqueous phase which passes through the…

research product

Comparison of different sorbents for on-line liquid-solid extraction followed by high-performance liquid chromatographic determination of nitrogen-containing pesticides

Abstract LiChrolut EN [poly(styrene-divinylbenzene), PSDVB], Carbograph (graphitized carbon black, GCB), Isolute CN (cyanopropylsilica), Isolute C 2 (ethylsilica), and LiChrospher RP18 (octadecylsilica) were studied for on-line solid-phase extraction of twelve nitrogen containing pesticides from water. Determination (UV 210 nm) was performed with a Spherisorb C 8 analytical column and an acetonitrile-water gradient. The mean recoveries from 50 ml ranged from 83% for RP18 to 44% for GCB, and decreased in the following order: RP18, CN, LiChrolut EN, C 2 , and GCB. GCB showed poor recoveries due to incomplete desorption with the acetonitrile-water gradient used, and memory effects were detecte…

research product

Dissipation and distribution of atrazine, simazine, chlorpyrifos, and tetradifon residues in citrus orchard soil.

An environmental fate study was conducted in a citrus orchard plot in Valencia (Spain) in the fall of 1993. Dissipation and distribution of atrazine, simazine, chlorpyrifos and tetradifon residues following their controlled addition for agricultural purposes in a mediterranean red soil (Luvic Calcisol, Rhodoxeralf) were evaluated. During a two-month period, the amounts of applied pesticides in different soil layers (0-0.05, 0.05-0.22, 0.22-0.42, and 0.42-0.52 m) were monitored. In addition, information on soils, weather and agricultural practice were collected. Degradation half-lives were calculated, assuming zero-order kinetics: 11 days for atrazine, 12 days for simazine, 10 days for chlor…

research product