0000000000182483
AUTHOR
Daniela Klitscher
Intramedullary nailing vs. palmar locked plating for unstable dorsally comminuted distal radius fractures: A biomechanical study
Abstract Background The purpose of this study was to compare the stability of a 2.4 mm palmar locking compression plate and a new intramedullary nail-plate-hybrid Targon DR for dorsally comminuted distal radius fractures. Methods An extraarticular 10 mm dorsally open wedge osteotomy was created in 8 pairs of fresh frozen human radii to simulate an AO–A3-fracture. The fractures were stabilized using one of the fixation methods. The specimens were loaded axially with 200 N and dorsal-excentrically with 80 N. 2000 cycles of dynamic loading and axial loading-to-failure were performed. Findings Axial loading revealed that intramedullary osteosynthesis (Targon DR: 369 N/mm) was significantly ( p …
Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable distal radius plates.
Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The si…
Fraktur des Os capitatum bei einem 11-jährigen Jungen
We report the case of an isolated non-displaced fracture of the capitate in an 11-year-old boy. On the basis of the relevant literature we present a survey of the diagnostic and treatment options. To the best of our knowledge this is the first description of a paediatric capitate fracture in the German-speaking area.
Locking plates for corrective osteotomy of malunited dorsally tilted distal radial fractures: a biomechanical study.
The purpose of the study was to compare the biomechanical properties of five different palmar fixation plate designs in a distal radius osteotomy cadaver model. A 1 cm metaphyseal osteotomy gap was made to simulate a corrective osteotomy and the osteotomy plated. Axial load was applied to the distal end of each construct by a material testing machine under control of a motion analysis video system. The specimens were arranged into five implant groups of eight specimens each. No test group developed deformity and movement of the fracture gap greater than 2 mm with a load of 100 N. Increasing the load to 250 N revealed statistically significant differences in stiffness and failure load betwe…
Volar Fixed-Angle Plating of Distal Radius Fractures
The purpose of this biomechanical study was to determine whether a multidirectional fixed-angle plate with locking screws or with locking pegs in the distal fragment would optimize fixation of Orthopaedic Trauma Association (OTA) type A3 distal radius fractures.Eight pairs of fresh-frozen human distal radii were used. Extra-articular distal radius fractures were created and stabilized with a multidirectional volar fixed-angle plate. The radii were randomized into 2 matched-paired groups. The distal fragment in Group I was stabilized with 7 locking screws. The distal fragment in Group II was fixed with 7 locking pegs. The proximal fragment in both groups was fixed with 3 screws. The specimen…