0000000000182483

AUTHOR

Daniela Klitscher

showing 5 related works from this author

Intramedullary nailing vs. palmar locked plating for unstable dorsally comminuted distal radius fractures: A biomechanical study

2010

Abstract Background The purpose of this study was to compare the stability of a 2.4 mm palmar locking compression plate and a new intramedullary nail-plate-hybrid Targon DR for dorsally comminuted distal radius fractures. Methods An extraarticular 10 mm dorsally open wedge osteotomy was created in 8 pairs of fresh frozen human radii to simulate an AO–A3-fracture. The fractures were stabilized using one of the fixation methods. The specimens were loaded axially with 200 N and dorsal-excentrically with 80 N. 2000 cycles of dynamic loading and axial loading-to-failure were performed. Findings Axial loading revealed that intramedullary osteosynthesis (Targon DR: 369 N/mm) was significantly ( p …

Orthodonticsmedicine.medical_specialtyMaterials scienceOsteosynthesisBiophysicsRadiusLocked platingIn Vitro TechniquesCompression (physics)Biomechanical PhenomenaFracture Fixation Intramedullarylaw.inventionSurgeryIntramedullary rodFracture Fixation InternalFixation (surgical)lawLoad to failureFresh frozenmedicineHumansOrthopedics and Sports MedicineRadius FracturesBone PlatesFractures ComminutedClinical Biomechanics
researchProduct

Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable dis…

2012

Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The si…

Compressive StrengthFrictionbusiness.industryBone ScrewsBiomedical EngineeringRadiusStructural engineeringProsthesis DesignInternal FixatorsMechanism (engineering)Equipment Failure AnalysisCompressive strengthFlexural strengthBreakageElastic ModulusTensile StrengthBone plateUltimate tensile strengthBending momentHumansbusinessRadius FracturesBone PlatesBiomedizinische Technik. Biomedical engineering
researchProduct

Fraktur des Os capitatum bei einem 11-jährigen Jungen

2010

We report the case of an isolated non-displaced fracture of the capitate in an 11-year-old boy. On the basis of the relevant literature we present a survey of the diagnostic and treatment options. To the best of our knowledge this is the first description of a paediatric capitate fracture in the German-speaking area.

medicine.medical_specialtybusiness.industryRadiographyGeneral surgeryMEDLINETreatment optionsOs CapitatumSurgerymedicineFracture (geology)Orthopedics and Sports MedicineSurgerybusinessRange of motionHandchirurgie · Mikrochirurgie · Plastische Chirurgie
researchProduct

Locking plates for corrective osteotomy of malunited dorsally tilted distal radial fractures: a biomechanical study.

2005

The purpose of the study was to compare the biomechanical properties of five different palmar fixation plate designs in a distal radius osteotomy cadaver model. A 1 cm metaphyseal osteotomy gap was made to simulate a corrective osteotomy and the osteotomy plated. Axial load was applied to the distal end of each construct by a material testing machine under control of a motion analysis video system. The specimens were arranged into five implant groups of eight specimens each. No test group developed deformity and movement of the fracture gap greater than 2 mm with a load of 100 N. Increasing the load to 250 N revealed statistically significant differences in stiffness and failure load betwe…

Malemedicine.medical_treatmentVideo RecordingOsteotomyProsthesis DesignWeight-BearingFixation (surgical)Fracture Fixation InternalCadaverBone plateFracture fixationMaterials TestingmedicineDeformityCadaverHumansAgedOrthodonticsTransplantationbusiness.industryAnatomyOsteotomyEquipment Failure Analysismedicine.anatomical_structureSurgeryCortical boneFemalemedicine.symptombusinessRadius FracturesCancellous boneBone PlatesJournal of hand surgery (Edinburgh, Scotland)
researchProduct

Volar Fixed-Angle Plating of Distal Radius Fractures

2011

The purpose of this biomechanical study was to determine whether a multidirectional fixed-angle plate with locking screws or with locking pegs in the distal fragment would optimize fixation of Orthopaedic Trauma Association (OTA) type A3 distal radius fractures.Eight pairs of fresh-frozen human distal radii were used. Extra-articular distal radius fractures were created and stabilized with a multidirectional volar fixed-angle plate. The radii were randomized into 2 matched-paired groups. The distal fragment in Group I was stabilized with 7 locking screws. The distal fragment in Group II was fixed with 7 locking pegs. The proximal fragment in both groups was fixed with 3 screws. The specimen…

MaleBone ScrewsBone NailsBiomechanical PhenomenaFracture Fixation InternalFixation (surgical)Fixed angleCadaverFracture fixationBone plateCadaverHumansMedicineOrthopedics and Sports MedicineAgedMechanical PhenomenaAged 80 and overOrthodonticsbusiness.industryGeneral MedicineRadiusMiddle AgedBiomechanical PhenomenaProsthesis FailureEquipment Failure AnalysisFemaleSurgeryRadius FracturesbusinessCadaveric spasmBone PlatesJournal of Orthopaedic Trauma
researchProduct