0000000000185443
AUTHOR
C. Grüning
Resonance ionization mass spectrometry for ultratrace analysis of plutonium with a new solid state laser system
Abstract Resonance ionization mass spectrometry (RIMS) is well-suited for isotope selective ultratrace analysis of long-lived radioactive isotopes due to its high element and isotope selectivity and good sensitivity. For the analysis of plutonium with a pulsed RIMS apparatus, a powerful, reliable and easy to handle Nd:YAG pumped titanium–sapphire laser system has been developed and combined with a time-of-flight mass spectrometer. Spectroscopic measurements led to an efficient three step excitation and ionization scheme for plutonium with λ1 = 420.76 nm, λ2 = 847.28 nm, and λ3 = 767.53 nm. The isotope shifts in this scheme for the plutonium isotopes 238 Pu through 244 Pu have been determine…
First Observation of Atomic Levels for the Element Fermium (Z=100)
The atomic level structure of the element fermium was investigated for the first time using a sample of $2.7\ifmmode\times\else\texttimes\fi{}{10}^{10}$ atoms of the isotope $^{255}\mathrm{F}\mathrm{m}$ with a half-life of 20.1 h. The atoms were evaporated from a filament and stored in the argon buffer gas of an optical cell. Atomic levels were sought by the method of resonance ionization spectroscopy using an excimer-dye-laser combination. Two atomic levels were found at wave numbers $(25\text{ }099.8\ifmmode\pm\else\textpm\fi{}0.2)$ and $(25\text{ }111.8\ifmmode\pm\else\textpm\fi{}0.2)\text{ }\text{ }{\mathrm{c}\mathrm{m}}^{\ensuremath{-}1}$. Partial transition rates to the $5{f}^{12}7{s}…
First Determination of the Ionization Potential of Actinium and First Observation of Optical Transitions in Ferminm
For the determination of the first ionization potential of actinium, 227Ac was electrodeposited on a Ta backing and covered with ~1 μm Zr. From this filament, Ac atoms were evaporated at ≥ 1250 °C. By resonant excitation with UV light of 388.67 nm and subsequent excitation with light of ca. 568 nm, Ac was ionized in an external electrical field. By determining the ionization thresholds as a function of the electrical field strength and by extrapolation to zero field strength, the first ionization potential of 43398(3) cm−1 = 5.3807(3) eV was measured.About 1 ng of 255Fm, half life 20.1 h, was prepared at ORNL by milking from 255Es produced in the High Flux Isotope Reactor and shipped to Mai…
Resonance ionization spectroscopy of fermium (Z=100)
Laser spectroscopy has been applied for the first time to measure resonant transition frequencies of fermium (Zs 100). A number of 2.7=10 atoms was electrodeposited on a Ta filament and covered with a 1 mm Ti layer. Fm 10
Recent developments in and applications of resonance ionization mass spectrometry
Resonance Ionization Mass Spectrometry (RIMS) has nowadays reached the status of a routine method for sensitive and selective ultratrace determination of long-lived radioactive isotopes in environmental, biomedical and technical samples. It provides high isobaric suppression, high to ultra-high isotopic selectivity and good overall efficiency. Experimental detection limits are as low as 106 atoms per sample and permit the fast and sensitive determination of ultratrace amounts of radiotoxic contaminations. Experimental arrangements for the detection of different radiotoxic isotopes, e.g. 236–244Pu, 89,90Sr and 99Tc in environmental samples are described, and the application of RIMS to the ul…