0000000000188232
AUTHOR
Giuseppe Riccio
Euclid preparation. XII. Optimizing the photometric sample of the Euclid survey for galaxy clustering and galaxy-galaxy lensing analyses
Pocino, A., et al. (Euclid Collaboration)
Euclid preparation XV. Forecasting cosmological constraints for the Euclid and CMB joint analysis
The combination and cross-correlation of the upcoming $Euclid$ data with cosmic microwave background (CMB) measurements is a source of great expectation since it will provide the largest lever arm of epochs, ranging from recombination to structure formation across the entire past light cone. In this work, we present forecasts for the joint analysis of $Euclid$ and CMB data on the cosmological parameters of the standard cosmological model and some of its extensions. This work expands and complements the recently published forecasts based on $Euclid$-specific probes, namely galaxy clustering, weak lensing, and their cross-correlation. With some assumptions on the specifications of current and…
Euclid preparation: XI. Mean redshift determination from galaxy redshift probabilities for cosmic shear tomography
Ilbert, O., et al. (Euclid Collaboration)
Euclid preparation - XVII. Cosmic Dawn Survey: Spitzer Space Telescope observations of the Euclid deep fields and calibration fields
Artículo escrito por un elevado núnmero de autores, sólo se referencian el qque aparece en primer lugar, los autores pertenecientes a la UAM y el nombre del grupo de colaboración, si lo hubiere
An Experimental Investigation on the Air Permeability of Passive Ventilation Grilles
Abstract The need of increasing both energy saving and acoustic insulation has leaded to the design of lowest air permeability frames resulting in the worsening of indoor air quality. Moreover, sometime in several civil-use existing buildings (i.e. schools or houses, historical buildings) mechanical ventilation systems cannot be installed due to non-removable constraints. In these cases, passive ventilation grilles are a cheap and effective solution for the ventilation. This work deals with an in-depth experimental analysis about the air permeability values measured over a set of passive ventilation grilles available on the market. Obtained results often showed performances very far to thos…
Fifty Years of PMV Model: Reliability, Implementation and Design of Software for Its Calculation
In most countries, PMV is the reference index for the assessment of thermal comfort conditions in mechanically conditioned environments. It is also the basis to settle input values of the operative temperature for heating and cooling load calculations, sizing of equipment, and energy calculations according to EN 16798-1 and 16798-2 Standards. Over the years, great effort has been spent to study the reliability of PMV, whereas few investigations were addressed to its calculation. To study this issue, the most significant apps devoted to its calculation have been compared with a reference software compliant with EN ISO 7730 and the well-known ASHRAE Thermal Comfort Tool. It has been revealed …
Mean Radiant Temperature Measurements through Small Black Globes under Forced Convection Conditions
One of the most critical variables in the field of thermal comfort measurements is the mean radiant temperature which is typically measured with a standard 150 mm black globe thermometer. This is also the reference instrument required for the assessment of heat stress conditions by means of the well-known Wet Bulb Globe Temperature index (WBGT). However, one of the limitations of this method is represented by the relatively long response time. This is why in recent years there has been a more and more pressing need of smart sensors for controlling Heating Ventilation and Air Conditioning (HVAC) systems, and for pocket heat stress meters (e.g., WBGT meters provided with table tennis balls). …
Euclid Preparation. XIV. The Complete Calibration of the Color–Redshift Relation (C3R2) Survey: Data Release 3
Stanford, S. A., et al.