0000000000188547
AUTHOR
L. Steiger
Experimental investigation of transverse spin asymmetries in muon-p SIDIS processes: Sivers asymmetries
The COMPASS Collaboration at CERN has measured the transverse spin azimuthal asymmetry of charged hadrons produced in semi-inclusive deep inelastic scattering using a 160 GeV positive muon beam and a transversely polarised NH_3 target. The Sivers asymmetry of the proton has been extracted in the Bjorken x range 0.003 0.03. The asymmetry is different from zero and positive also in the low x region, where sea-quarks dominate. The kinematic dependence of the asymmetry has also been investigated and results are given for various intervals of hadron and virtual photon fractional energy. In contrast to the case of the Collins asymmetry, the results on the Sivers asymmetry suggest a strong depende…
Search for exclusive photoproduction ofZc±(3900) at COMPASS
A search for the exclusive production of the Z(c)(+/-)(3900) hadron by virtual photons has been performed in the channel Z(c)(+/-)(3900). J/Psi pi(+/-). The data cover the range from 7GeV to 19GeV in the centre-of- mass energy of the photon-nucleon system. The full set of the COMPASS data set collected with a muon beam between 2002 and 2011 has been used. An upper limit for the ratio BR(Z(c)(+/-)(3900)-> J/Psi pi(+/-)) x sigma(gamma N) -> Z(c)(+/-)(3900) N/sigma gamma N -> J/Psi N 3.7 x10(-3) has been established at the confidence level of90%. (C) 2015 The Authors. Published by Elsevier B.V.
Read-out electronics for fast photon detection with COMPASS RICH-1
A new read-out electronics system has been developed for the fast photon detection of the central region of the COMPASS RICH-1. The project is based on multi-anode photomultipliers read out by the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1 TDC chip characterised by high time resolution. The system has been designed taking into account the high photon flux in the central region of the detector and the high rate requirement of the COMPASS experiment. The system is described in detail together with the measured performances. The new electronics system has been installed and used for the 2006 data taking; it entirely fulfils the expected performances.
Spin alignment and violation of the OZI rule in exclusive ω and ϕ production in pp collisions
Exclusive production of the isoscalar vector mesons $\omega$ and $\phi$ is measured with a 190 GeV$/c$ proton beam impinging on a liquid hydrogen target. Cross section ratios are determined in three intervals of the Feynman variable $x_{F}$ of the fast proton. A significant violation of the OZI rule is found, confirming earlier findings. Its kinematic dependence on $x_{F}$ and on the invariant mass $M_{p\mathrm{V}}$ of the system formed by fast proton $p_\mathrm{fast}$ and vector meson $V$ is discussed in terms of diffractive production of $p_\mathrm{fast}V$ resonances in competition with central production. The measurement of the spin density matrix element $\rho_{00}$ of the vector mesons…
The fast photon detection system of COMPASS RICH-1
Abstract A fast photon detection system has been built for the upgrade of COMPASS RICH-1, the large size gaseous RICH detector in use at the COMPASS Experiment at the CERN SPS since 2001. The photon detectors of the central region have been replaced by a new system based on multi-anode photomultipliers coupled to individual fused silica lens telescopes and a fast readout electronics system, while in the outer region the existing MWPCs with CsI photocathodes have been equipped with a new readout system, based on the APV chip. RICH-1 has been successfully operated in its upgraded version during the 2006 run. We report on the upgrade design and construction, and on the preliminary characteriza…
Pattern recognition and PID for COMPASS RICH-1
A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has allowed the full characterization of the detector in the starting version and in the upgraded one, as well as the PID for physics results. We report about the package structure and algorithms, and the detector characterization and PID results.
Design and status of COMPASS FAST-RICH
In the context of the upgrade of COMPASS RICH-1, we are developing a fast photodetection system for RICH counters, based on UV extended Multi-Anode PhotoMultiplier Tubes (MAPMT) and a custom, low dead-time electronic readout system. Photons are concentrated on the MAPMT photocathode by an optical system that preserves the position information. The ratio between the collection and the photosensitive surfaces is ∼7.5 in our design, larger than in previous applications. A new front-end electronics, based on a modified version of the MAD4 discriminator chip, is being realized to digitize the MAPMT signals. We report about the design of the photodetection system and of the associated electronic …
Particle identification with COMPASS RICH-1
International audience; RICH-1 is a large size RICH detector in operation at the COMPASS experiment since 2001 and recently upgraded implementing a new photon detection system with increased performance.A dedicated software package has been developed to perform RICH-1 data reduction, pattern recognition and particle identification as well as a number of accessory tasks for detector studies.The software package, the algorithms implemented and the detector characterisation and performance are reported in detail.
The fast readout system for the MAPMTs of COMPASS RICH-1
A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The system is designed as a very compact setup and is mounted directly behind the multi-anode photomultiplie…
Exclusive muoproduction on transversely polarised protons and deuterons
The transverse target spin azimuthal asymmetry A(UT)(sin(phi-phi s)) in hard exclusive production of rho(0) mesons was measured at COMPASS by scattering 160 GeV/c muons off transversely polarised protons and deuterons. The measured asymmetry is sensitive to the nucleon helicity-flip generalised parton distributions E-q, which are related to the orbital angular momentum of quarks in the nucleon. The Q(2), x-B-j and p(T)(2) dependence of A(UT)(sin(phi-phi s)) is presented in a wide kinematic range: 1 (GeV/c)(2) < Q(2) < 10 (GeV/c)(2), 0.003 < xB(j) < 0.3 and 0.05 (GeV/c)(2) < p(T)(2) < 0.5 (GeV/c)(2) for protons or 0.10 (GeV/c)(2) < p(T)(2) < 0.5 (GeV/c)(2) for deuterons. Results for deuteron…
The COMPASS Setup for Physics with Hadron Beams
The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well as new or upgraded detectors. The hadron setup is able to operate at the high incident hadron flux available at CERN. It is characterised by large angular and momentum coverages, large and nearly flat acceptances, and good two and three-particle mass resolutions. In 2008 and 2009 it was successful…
Particle identification with the fast COMPASS RICH-1 detector
International audience; A new photon detection system for the COMPASS RICH-1 detector has been designed and installed. In the central region, the project is based on multi-anode photo-multiplier technology accompanied by charge sensitive, high resolution and dead-time free time digitization. In the outer area, only the readout electronics for the existing photon detectors has been replaced. Details on the detector upgrade and its performance are presented.
The experience of building and operating COMPASS RICH-1
COMPASS RICH-1 is a large size gaseous Imaging Cherenkov Detector providing hadron identification in the range from 3 to 55 GeV/c, in the wide acceptance spectrometer of the COMPASS Experiment at CERN SPS. It uses a 3 m long C(4)F(10) radiator, a 21 m(2) large VUV mirror surface and two kinds of photon detectors: MAPMTs and MWPCs with CsI photocathodes, covering a total of 5.5 m(2). It is in operation since 2002 and its performance has increased in time thanks to progressive optimization and mostly to a major upgrade which was implemented in 2006. The main characteristics of COMPASS RICH-1 components are described and some specific aspects related to the radiator gas system, the mirror alig…
The COMPASS RICH-1 fast photon detection system
Abstract A fast photon detection system has been built as a part of the upgrade of the COMPASS RICH-1 detector: it is based on 576 multi-anode photomultiplier tubes (MAPMTs) coupled to individual fused silica lens telescopes and fast readout electronics. This system has replaced the MWPCs with CsI photo-cathodes in the central region ( 1.3 m 2 , 25% of the total area) of the COMPASS RICH-1 photon detectors and has successfully been operated during the data taking in 2006 and 2007. We report about the fast photon detection system design, construction and commissioning, in particular about the design optimization and the validation tests of the lens telescopes. Preliminary values for the incr…
Erratum to: Hadron transverse momentum distributions in muon deep inelastic scattering at 160 GeV/ $$c$$ c
Author(s): Adolph, C; Alekseev, MG; Alexakhin, VY; Alexandrov, Y; Alexeev, GD; Amoroso, A; Andrieux, V; Austregesilo, A; Badelek, B; Balestra, F; Barth, J; Baum, G; Bedfer, Y; Berlin, A; Bernhard, J; Bertini, R; Bicker, K; Bieling, J; Birsa, R; Bisplinghoff, J; Boer, M; Bordalo, P; Bradamante, F; Braun, C; Bravar, A; Bressan, A; Buchele, M; Burtin, E; Capozza, L; Chiosso, M; Chung, SU; Cicuttin, A; Crespo, ML; Dalla Torre, S; Dasgupta, SS; Dasgupta, S; Denisov, OY; Donskov, SV; Doshita, N; Duic, V; Dunnweber, W; Dziewiecki, M; Efremov, A; Elia, C; Eversheim, PD; Eyrich, W; Faessler, M; Ferrero, A; Filin, A; Finger, M; Finger Jr, M; Fischer, H; Franco, C; du Fresne von Hohenesche, N; Friedri…
The characterisation of the multianode photomultiplier tubes for the RICH-1 upgrade project at COMPASS
Abstract A major upgrade of the Cherenkov photon detection system of COMPASS RICH-1 has been performed and it has been in operation since the 2006 physics run. The inner part of the photon detector has been replaced by a different technology in order to measure Cherenkov photons at high photoelectron rates, up to several times 10 6 per second and per channel. Cherenkov photons from 200 to 750 nm are detected by 576 multianode photomultiplier tubes (MAPMTs) with 16 channels each, coupled to individual fused silica lens telescopes and fast, high sensitivity and high time resolution electronics read-out. To guarantee an optimal performance of the complete system, parameters like dark current, …
Design and construction of the fast photon detection system for COMPASS RICH-1
International audience; New photon detectors, based on the use of multi-anode photo-multiplier tubes coupled to individual lens telescopes and read out with a dedicated read-out electronics system, equip the central region of the Cherenkov imaging counter RICH-1 of the COMPASS experiment at CERN SPS. They are characterised by high photon yield, fast response and high rate capability and are successfully in operation since the 2006 COMPASS data taking. The photon detection system fully matches the expected performance. The design and construction of the photon detectors are described in detail.
Study of Σ(1385) and Ξ(1321) hyperon and antihyperon production in deep inelastic muon scattering
Large samples of \Lambda, \Sigma(1385) and \Xi(1321) hyperons produced in deep-inelastic muon scattering off a ^6LiD target were collected with the COMPASS experimental setup at CERN. The relative yields of \Sigma(1385)^+, \Sigma(1385)^-, \bar{\Sigma}(1385)^-, \bar{\Sigma}(1385)^+, \Xi(1321)^-, and \bar{\Xi}(1321)^+ hyperons decaying into \Lambda(\bar{\Lambda})\pi were measured. The heavy hyperon to \Lambda and heavy antihyperon to \bar{\Lambda} yield ratios were found to be in the range 3.8% to 5.6% with a relative uncertainty of about 10%. They were used to tune the parameters relevant for strange particle production of the LEPTO Monte Carlo generator.
Fast photon detection for COMPASS RICH-1
A fast photon detection system has been built and assembled for the upgrade of COMPASS RICH-1. The system is based on multianode photomultipliers coupled to fused silica lenses to collect the light from a larger surface and to guide it to the photocathode, preserving the position information. The emphasis is on the fast response and high rate capability of the detectors and the associated electronics. The photon detection system is now ready and it will be employed in the 2006 COMPASS data taking. We report about the system design and construction.
Collins and Sivers asymmetries in muonproduction of pions and kaons off transversely polarised protons
Measurements of the Collins and Sivers asymmetries for charged pions and charged and neutral kaons produced in semi-inclusive deep-inelastic scattering of high energy muons off transversely polarised protons are presented. The results were obtained using all the available COMPASS proton data, which were taken in the years 2007 and 2010. The Collins asymmetries exhibit in the valence region a non-zero signal for pions and there are hints of non-zero signal also for kaons. The Sivers asymmetries are found to be positive for positive pions and kaons and compatible with zero otherwise.
Measurement of azimuthal hadron asymmetries in semi-inclusive deep inelastic scattering off unpolarised nucleons
Spin-averaged asymmetries in the azimuthal distributions of positive and negative hadrons produced in deep inelastic scattering were measured using the CERN SPS muon beam at $160$ GeV/c and a $^6$LiD target. The amplitudes of the three azimuthal modulations $\cos\phi_h$, $\cos2\phi_h$ and $\sin\phi_h$ were obtained binning the data separately in each of the relevant kinematic variables $x$, $z$ or $p_T^{\,h}$ and binning in a three-dimensional grid of these three variables. The amplitudes of the $\cos \phi_h$ and $\cos 2\phi_h$ modulations show strong kinematic dependencies both for positive and negative hadrons.
Measurement of the Charged-Pion Polarizability
The COMPASS collaboration at CERN has investigated pion Compton scattering, $\pi^-\gamma\rightarrow \pi^-\gamma$, at centre-of-mass energy below 3.5 pion masses. The process is embedded in the reaction $\pi^-\mathrm{Ni}\rightarrow\pi^-\gamma\;\mathrm{Ni}$, which is initiated by 190\,GeV pions impinging on a nickel target. The exchange of quasi-real photons is selected by isolating the sharp Coulomb peak observed at smallest momentum transfers, $Q^2<0.0015$\,(GeV/$c$)$^2$. From a sample of 63\,000 events the pion electric polarisability is determined to be $\alpha_\pi\ =\ (\,2.0\ \pm\ 0.6_{\mbox{\scriptsize stat}}\ \pm\ 0.7_{\mbox{\scriptsize syst}}\,) \times 10^{-4}\,\mbox{fm}^3$ under the …
Corrigendum to “Odd and even partial waves of ηπ− and η′π− in π−p → η(′)π−p at 191 GeV/c” [Phys. Lett. B 740 (2015) 303–311]
Abstract In Fig. 5 on p. 311 of our Phys. Lett. B 740 (2015) 303 an adjustment by 180 ∘ is required for the phases with respect to the L = 2 , M = 1 wave, of the following waves: L = 1 , 3 , 5 with M = 1 , and L = 2 with M = 2 . After this correction (Fig. 5 (corrected) below), the extracted partial waves describe the angular distribution of the η ( ′ ) in the Gottfried-Jackson (GJ) frame, using Eq. (4) with implicit Condon-Shortley phase convention. The other results of our paper are not affected. The right-handed GJ coordinate system was defined by the z-axis pointing in the direction of the beam in the η ( ′ ) π − center-of-mass system and the y-axis pointing in the direction of p recoil…
A highly integrated low-cost readout system for the COMPASS RICH-1 detector
Particle identification at high multiplicities is a key feature of the COMPASS experiment at CERN's SPS. Hadrons up to 50 GeV/c are identified by a RICH detector with a large horizontal and vertical acceptance of plusmn250 mrad and plusmn180 mrad, respectively. The central region of the photon detector is equipped with multi-anode photomultiplier tubes, the remaining 75% of the total active area are covered by MWPCs with Csl photocathodes. In order to improve the performance of the detector at very high beam intensities, more than 62000 channels of a new analog readout system of the MWPCs, based on the APV25 chip, were developed and installed in 2006. The new system features good single pho…