0000000000191099

AUTHOR

Alexandra Behneke

Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement.

Objectives The aim of the present investigation was the analysis of the factors presumptively affecting the accuracy outcome of cone-beam computed tomography (CBCT)-derived laboratory-based surgical guides for implant placement in partially edentulous patients. Materials and methods In 52 partially edentulous patients a total of 132 implants were placed following CBCT diagnostics with the aid of laboratory-fabricated, tooth-borne templates. Based on the image fusion technique measurements were done to calculate linear and angular deviations between virtually planned and placed implants. The implant sites were stratified according to four factors that presumably may influence the transfer ac…

research product

Randomized multicenter comparison of two coatings of intramobile cylinder implants in 313 partially edentulous mandibles followed up for 5 years

Intramobile cylinder (IMZ) implants with either of two coatings, hydroxyapatite (HA) or titanium plasma-flame (TPF), as distal abutments for combined tooth implant-supported restorations, were compared in 313 partially edentulous mandibles with respect to postprosthetical failure patterns and complication frequencies in a randomized multicenter clinical trial. Within the treatment protocols, the two coatings do not show evidence of different efficacy with respect to occurrence of postprosthetical integration deficiency (ID) or functional deficiency (FD). Statistical equivalence for an absolute effect of +/-15% in event-free survival could only be demonstrated for FD, not for ID, however. In…

research product

Accuracy assessment of cone beam computed tomography-derived laboratory-based surgical templates on partially edentulous patients

Objectives: The aim of the present prospective clinical study was to evaluate the match between the positions and axes of the virtually planned and the placed implants using laboratory-based surgical guides generated from cone beam computed tomography (CBCT). Materials and methods: A total of 132 implants were placed with the aid of 3D-based transfer templates in 52 consecutive partially edentulous patients between April 2008 and March 2010. After individual adaptation of the scan templates and CBCT scanning, the acquired data for virtual implant planning and simulation were processed using the med3D software program. After finalizing the virtual placement of the implants the radiographic t…

research product

Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants.

In the present multi-center study. non-submerged ITI implants were prospectively followed to evaluate their long-term prognosis in fully and partially edentulous patients. In a total of 1003 patients, 2359 implants were consecutively inserted. Following a healing period of 3–6 months, the successfully integrated implants were restored with 393 removable and 758 fixed restorations. Subsequently, all consecutive implants were documented annually up to 8 years. At each examination, the clinical status of all implants was evaluated according to predefined criteria of success. Therefore, the data base allowed the evaluation of 8-year cumulative survival and success rates for 2359 implants. In ad…

research product