0000000000191510

AUTHOR

Germán Cánovas-ambit

0000-0001-5547-5407

showing 3 related works from this author

Validity and reliability of Veloflex to measure active cervical range of motion in asymptomatic and symptomatic subjects

2021

Background Neck pain has a high annual incidence and decreases the cervical active range of motion (ROM). Clinicians use various methods to evaluate cervical range of motion (CROM) that some of them have also been proposed to give instant feedback. Accordingly, this study aimed to examine the validity and reliability of Veloflex (VF) to measure the CROM by comparison with the cervical range of motion (CROM) device, and to examine their test-retest reliability. Methods Thirty-eight healthy and 20 symptomatic participants were evaluated. Cervical flexion-extension, side bending, and rotations were tested in two sessions, first by the CROM and VF and in the second only with the VF. To evaluat…

Cervical range of motionDrugs and Devices030506 rehabilitationmedicine.medical_specialtyAnatomy and PhysiologyConcurrent validityValidity/reliabilitylcsh:MedicineValidityAsymptomaticGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciencessymbols.namesake0302 clinical medicinePhysical medicine and rehabilitationMedicineRange of motionAnesthesiology and Pain ManagementOptoelectronic deviceReliability (statistics)business.industryGeneral Neurosciencelcsh:RGeneral MedicineKinesiologyPearson product-moment correlation coefficientOrthopedicsStandard errorsymbolsCervicalmedicine.symptom0305 other medical scienceGeneral Agricultural and Biological SciencesRange of motionbusiness030217 neurology & neurosurgeryPeerJ
researchProduct

An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study.

2019

Background and Objectives: Within the clinical evaluation of multiple pathologies of the lower limb, the measurement of range of motion (ROM) of its joints is fundamental. To this end, there are various tools, from the goniometer as a reference to more recent devices such as inclinometry-based applications, photo capture applications, or motion capture systems. This study aimed to assess the validity, intra-rater, and inter-rater reliability of the VeloFlex system (VS), which is a new camera-based tool designed for tracking joint trajectories and measuring joint ROM. Materials and Methods: Thirty-five healthy volunteers (16 females

musculoskeletal diseasesAdultMaleMedicine (General)AdolescentCross-sectional studyConcurrent validityeducationMesurament -- InstrumentsArticlerange of motionsymbols.namesakeYoung AdultR5-920articular goniometryHealthy volunteersMedicineHumanslower extremity; range of motion; reproducibility of results; articular goniometryRange of Motion ArticularReliability (statistics)Leg -- DiseasesOrthodonticsObserver VariationArthrometry Articularbusiness.industryOrthopedic EquipmentReproducibility of ResultsGeneral MedicineMiddle AgedPearson product-moment correlation coefficientHealthy VolunteersStandard errorCross-Sectional StudiesLower ExtremityCames -- MalaltiesGoniometersymbolsMeasuring instrumentsFemaleRange of motionbusinessMedicina (Kaunas, Lithuania)
researchProduct

Validity and Reliability of a New Optoelectronic System for Measuring Active Range of Motion of Upper Limb Joints in Asymptomatic and Symptomatic Sub…

2019

The aim of this study was to evaluate the validity of the Veloflex infrared dynamic angle-meter (Veloflex-IDA) and the intra- and inter-rater reliability when measuring the ranges of motion (ROMs) of the upper limb joints. Thirty-five healthy and 20 symptomatic participants were evaluated. Twelve upper limb movements were measured in two sessions with the Veloflex-IDA, which is a device composed of a camera that tracks the trajectory of retro-reflective markers. In addition, a goniometer was used in the first session to evaluate concurrent validity. Validity and agreement were evaluated by Pearson correlation coefficient (r) and Bland&ndash

educationConcurrent validityupper limb jointslcsh:MedicineValidityArticlerange of motion03 medical and health sciencessymbols.namesake0302 clinical medicineMedicineReliability (statistics)optoelectronic deviceOrthodontics030222 orthopedicsbusiness.industrylcsh:R030229 sport sciencesGeneral MedicinePearson product-moment correlation coefficientbiomedical technologyStandard errormedicine.anatomical_structureGoniometersymbolsUpper limbRange of motionbusinessJournal of Clinical Medicine
researchProduct