Exclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planning

2008

Purpose: According to the GYN GEC-ESTRO Recommendations, MRI is needed with the modality of T2 weighted. CT-MR compatible tandem Plus colpostats (T/C) (Nucletron) is widely used in cervical brachytherapy. The major challenge of MRI is the lack of dummy catheters. Therefore, an additional imaging modality is usually required. One disadvantage of sliced-based reconstruction is that resolution in longitudinal directions can be affected by the slice thickness. The aim of this study is to present a modified T/C applicator in which the catheter visibility is significantly improved. Methods and materials: A modification to the existing T/C applicator has been made available, increasing the cathete…

medicine.medical_specialtyGenital Neoplasms Femalebusiness.industryRadiotherapy Planning Computer-AssistedSlice thicknessmedicine.medical_treatmentBrachytherapyBrachytherapyRadiotherapy DosageHematologyMagnetic Resonance ImagingCatheterizationCatheterOncologymedicineHumansDosimetryFemaleRadiology Nuclear Medicine and imagingRadiologyNuclear medicinebusinessRadiation treatment planningT2 weighted
researchProduct

A program for the independent verification of brachytherapy planning system calculations

2010

Purpose: In this work a spreadsheet based program is presented that to a large extent independently verifies the calculations of individual plans of brachytherapy treatment planning systems for low dose rate, high dose rate and pulsed dose rate techniques.Material and methods: The verification program has been developed based on workbooks/spreadsheets. The treatment planning system output text files are automatically loaded into the new program, allowing the use of the source coordinates, the desired calculation point coordinates, and the dwell times of a patient plan. The source strength and the reference dates are entered by the user and then dose points calculations are independently per…

lcsh:RbrachytherapyTechnical Notelcsh:Medicineplanning systemphysics dosimetryverificationJournal of Contemporary Brachytherapy
researchProduct

Novel simple templates for reproducible positioning of skin applicators in brachytherapy.

2016

Purpose : Esteya and Valencia surface applicators are designed to treat skin tumors using brachytherapy. In clinical practice, in order to avoid errors that may affect the treatment outcome, there are two issues that need to be carefully addressed. First, the selected applicator for the treatment should provide adequate margin for the target, and second, the applicator has to be precisely positioned before each treatment fraction. In this work, we describe the development and use of a new acrylic templates named Template La Fe-ITIC. They have been designed specifically to help the clinical user in the selection of the correct applicator, and to assist the medical staff in reproducing the po…

0106 biological sciencesEngineering drawingmedicine.medical_specialtyMedical staffelectronic brachytherapymedicine.medical_treatmentTreatment outcomeBrachytherapybrachytherapylcsh:Medicine01 natural sciences03 medical and health sciences0302 clinical medicineMargin (machine learning)medicineRadiology Nuclear Medicine and imagingMedical physicsReview Paperskin cancerbusiness.industrylcsh:RtemplateThin sheetClinical Practiceskin applicatorsTemplateOncology030220 oncology & carcinogenesisbusiness010606 plant biology & botanyJournal of contemporary brachytherapy
researchProduct

The necessity of systematic verification of applicator position in brachytherapy treatment of the vaginal cuff

2009

Position (obstetrics)medicine.medical_specialtyOncologybusiness.industrymedicine.medical_treatmentBrachytherapyMedicineRadiology Nuclear Medicine and imagingbusinessVaginal cuffSurgeryBrachytherapy
researchProduct

Urethral Dose Limit in Boost Permanent Prostate 125I Seed Implants Based on Biologically Effective Dose Values

2010

medicine.medical_specialtyDose limitmedicine.anatomical_structureOncologyProstatebusiness.industrymedicineUrologyRadiology Nuclear Medicine and imaging125i seedbusinessEffective dose (pharmacology)SurgeryBrachytherapy
researchProduct

Dose Escalation in Permanent Brachytherapy for Prostate Cancer: Preliminary Results

2010

Prostate cancermedicine.medical_specialtyOncologybusiness.industrymedicine.medical_treatmentBrachytherapymedicineDose escalationRadiology Nuclear Medicine and imagingRadiologymedicine.diseasebusinessBrachytherapy
researchProduct

MRI based treatment planning in gynaecological brachytherapy

2008

medicine.medical_specialtyOncologybusiness.industrymedicine.medical_treatmentBrachytherapyMedicineRadiology Nuclear Medicine and imagingMedical physicsbusinessRadiation treatment planningBrachytherapy
researchProduct

Interobserver study of countouringbased on ultrasound image in real-time interactive prostate brachytherapy

2009

medicine.medical_specialtyOncologybusiness.industrymedicine.medical_treatmentMedicineRadiology Nuclear Medicine and imagingMedical physicsRadiologybusinessUltrasound imageProstate brachytherapyBrachytherapy
researchProduct

The use of nomograms in LDR-HDR prostate brachytherapy

2011

Purpose: The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapt ed to High Dose Rate (HDR). This work sets nomograms for LDR and HDR prostate-BT implants, which are applied to three different institutions that use different implant techniques. Material and methods: Patients treated throughout 2010 till April 2011 were considered for this study. This exam ple was chosen to be the representative of the latest implant tech…

medicine.medical_specialtygenetic structuresbusiness.industrymedicine.medical_treatmentlcsh:RBrachytherapylcsh:MedicinePermanent prostate brachytherapyquality assuranceNomogramprostate brachytherapyKermaOncologymedicineDosimetryOriginal ArticleRadiology Nuclear Medicine and imagingMedical physicsbusinessDose rateindependent verificationQuality assuranceProstate brachytherapynomogramsJournal of Contemporary Brachytherapy
researchProduct

SU-FF-T-62: Dosimetric Evaluation of An Internal Shielding Used with a HDR Skin Applicator

2009

Purpose: The Valencia HDR skin applicators are accessories of the microSelectron HDR afterloading system (Nucletron) cup shaped to limit the dose to the irradiation area. Applicators sizes are: diameter 2 and 3 cm. The typical prescription depth is 3 mm. This work aims to evaluate the backscatter and electron contamination of an internal shielding used to reduce the dose to the ocular globe when the lesion is located at the eyelid. Monte Carlo(MC) and experimental methods have been used. Method and Materials: The geometry has been: the Valencia applicator (2 cm diameter) on the surface of a solid polystyrene slab phantom; inside, a 2 mm lead slab located at 3 mm depth. MC simulation charact…

ScannerLead shieldingOpticsMaterials sciencebusiness.industryAbsorbed doseElectromagnetic shieldingMonte Carlo methodDosimetryGeneral MedicinebusinessBolus (radiation therapy)Imaging phantomMedical Physics
researchProduct

A practical MRI-based reconstruction method for a new endocavitary and interstitial gynaecological template

2015

Purpose: There are perineal templates for interstitial implants such as MUPIT and Syed applicators. Their limitations are the intracavitary component deficit and the necessity to use computed tomography (CT) for treatment planning since both applicators are non-magnetic resonance imaging (MRI) compatibles. To overcome these problems, a new template named Template Benidorm (TB) has been recently developed. Titanium needles are usually reconstructed based on their own artifacts, mainly in T1-weighted sequence, using the void on the tip as the needle tip position. Nevertheless, patient tissues surrounding the needles present heterogeneities that complicate the accurate identification of these …

medicine.medical_specialtyContouringArtifact (error)business.industryPlane (geometry)medicine.medical_treatmentgynecological templateBrachytherapybrachytherapy templatecatheter reconstructionReconstruction methodIntersection (Euclidean geometry)SurgeryOncologyLine (geometry)MedicineOriginal ArticleRadiology Nuclear Medicine and imaginginterstitial implantsbusinessRadiation treatment planningBiomedical engineeringJournal of Contemporary Brachytherapy
researchProduct

QA of dynamic MLC based on EPID portal dosimetry.

2010

Abstract Purpose Dynamic delivery of intensity modulated beams (dIMRT) requires not only accurate verification of leaf positioning but also a control on the speed of motion. The latter is a parameter that has a major impact on the dose delivered to the patient. Time consumed in quality assurance (QA) procedures is an issue of relevance in any radiotherapy department. Electronic portal imaging dosimetry (EPID) can be very efficient for routine tests. The purpose of this work is to investigate the ability of our EPID for detecting small errors in leaf positioning, and to present our daily QA procedures for dIMRT based on EPID. Methods and materials A Varian 2100 CD Clinac equipped with an 80 …

Quality ControlReproducibilityComputer sciencebusiness.industryElectrical Equipment and SuppliesSmall deviationsEpid dosimetryBiophysicsGeneral Physics and AstronomyGeneral MedicineLinear particle acceleratorPortal imagingGap widthDosimetryRadiology Nuclear Medicine and imagingbusinessRadiometryQuality assuranceSimulationBiomedical engineeringPhysica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
researchProduct

PO-1047: Late G3 toxicity in prostate cancer patients treated with escalated dose (ED) technique: technical dependence

2015

OncologyGynecologymedicine.medical_specialtybusiness.industryHematologymedicine.diseaseProstate cancerOncologyRadiology Nuclear Medicine and imagingInternal medicineToxicitymedicineRadiology Nuclear Medicine and imagingbusinessRadiotherapy and Oncology
researchProduct

SU-GG-T-227: Dynamic IMRT Split Beam Technique Verification Using EPID Based Dosimetry

2010

Purpose: On dynamic IMRT plans with Millenium 80 (Varian) fields wider of 15 cm must be splitted. Since the EPIDdosimetry software does not allow to sum splitted subfluences in the same dosimetric portal image they have to be measured separately and compared independently with the subfluences previously calculated by the TPS Eclipse. The purpose of our work is the development of a tool to: 1) analyze the correct match between the two abutted ports for splitted fields. 2) study the effect of gravity and analyze repercussions of possible misalignments and 3) illustrate that the gamma evaluation should be made with the global summed fluence per field instead of with the individual subfluences.…

PhysicsNormalization (statistics)business.industryGeneral MedicineOpticsSoftwareMedical imagingDosimetrybusinessNuclear medicineMATLABcomputerBeam (structure)Image-guided radiation therapyEclipsecomputer.programming_languageMedical Physics
researchProduct

Commissioning and quality assurance procedures for the HDR Valencia skin applicators

2016

The Valencia applicators (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) are cup-shaped tungsten applicators with a flattening filter used to collimate the radiation produced by a high-dose-rate (HDR) 192 Ir source, and provide a homogeneous absorbed dose at a given depth. This beam quality provides a good option for the treatment of skin lesions at shallow depth (3-4 mm). The user must perform commissioning and periodic testing of these applicators to guarantee the proper and safe delivery of the intended absorbed dose, as recommended in the standards in radiation oncology. In this study, based on AAPM and GEC-ESTRO guidelines for brachytherapy units and our experience, a set …

medicine.medical_specialtymedicine.medical_treatmentBrachytherapybrachytherapylcsh:MedicineCollimated light030218 nuclear medicine & medical imaging03 medical and health sciences192Ir0302 clinical medicine<SUP>192</SUP>IrmedicineDosimetryRadiology Nuclear Medicine and imagingMedical physicscommissioningRadiation treatment planningQAReview Paperdosimetrybusiness.industryValencia applicatorslcsh:RVisual inspectionOncologyHomogeneous030220 oncology & carcinogenesisAbsorbed dosebusinessQuality assuranceJournal of Contemporary Brachytherapy
researchProduct