Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool

2021

Purpose To assess the links between discomfort glare sensitivity and physiological factors such as eye biometry, refraction, skin phototype, age, and gender among a large sample of healthy human subjects. Methods A total of 489 participants who were 20 to 70 years old (241 men, 248 women) underwent discomfort glare threshold measurements via the LUMIZ 100. Eye biometry and optical quality were measured using a Zeiss IOLMaster 700 biometer and i.Profiler aberrometer. Iris color, skin tone, age, gender, eyeglasses use, chronotype, fatigue level, self-evaluation of light sensitivity, and time spent outdoors were determined. Statistical analysis was carried out using nonparametric Mann–Whitney …

AdultMalediscomfortiris colormedicine.medical_specialtyBiometrygenetic structuresPhotophobiaPopulationVision DisordersBiomedical EngineeringFrequency of usepupilAudiologyArticleIris colorYoung AdultHumansMedicineeducationFatigueAgededucation.field_of_studyLight sensitivitysunglasses usebusiness.industryskin toneGlare (vision)ChronotypeglareMiddle AgedOptical qualityOphthalmologyEyeglasseschronotypeFemalehealthy populationmedicine.symptomlightbusinessTranslational Vision Science & Technology
researchProduct

Performance of a new device for the clinical determination of light discomfort

2020

PURPOSE To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Repeated measures ANOVA, Kruskal-Wallis, and correlation analysis were applied to test for differences between repeated measures, and effect of age on reliability. RESULTS Discomfort thresholds obtained are well distributed across the light intensity…

AdultMalemedicine.medical_specialtyLightIntraclass correlationCoefficient of variationBiomedical Engineering030204 cardiovascular system & hematologyAudiologyStandard deviationYoung Adult03 medical and health sciences0302 clinical medicineHumansMedicineReliability (statistics)AgedReproducibilitybusiness.industryReproducibility of ResultsRepeated measures designGeneral MedicineRepeatabilityMiddle AgedLight intensityFemaleSurgerybusiness030217 neurology & neurosurgeryExpert Review of Medical Devices