An advanced system for the simulation and planning of orthodontic treatment
This paper presents a new system for three-dimensional (3-D) orthodontic treatment planning and movement of teeth. We describe a computer vision technique for the acquisition and processing of 3-D images of the profile of hydrocolloid dental imprints. Profile measurement is based on the triangulation method which detects deformation of the projection of a laser line on the dental imprints. The system is computer-controlled and designed to achieve depth and lateral resolutions of 0.1 and 0.2 mm, respectively, within a depth range of 40 mm. The 3-D image of the imprint is segmented in order to identify different teeth. Two operators are presented: one for the detection of molars and premolars…