Multi frequency phase fluorimetry (MFPF) for oxygen partial pressure measurement: ex vivo validation by polarographic clark-type electrode.

2013

BACKGROUND: Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. METHODOLOGY/PRINCIPAL FINDINGS: MFPF technology was first investigated in N = 8 anaesthetised pigs at FIO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each FIO2 level, blood samples were withdrawn and PO2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-PO2 readings were compared to CTE in an artificial circulatory s…

Drugs and DevicesAnatomy and PhysiologyMaterials scienceSwinePartial PressurePhase (waves)Analytical chemistrychemistry.chemical_elementlcsh:Medicine610 Medicine & healthBioengineeringCardiovascularCardiovascular SystemOxygenFluorescence spectroscopyMedical Devices03 medical and health sciencesEngineering0302 clinical medicineAnesthesiologyDiagnostic MedicineAnimalsFluorometryddc:610030212 general & internal medicine610 Medicine & healthlcsh:ScienceBiologyBlood gas analysisPolarographyChemical PhysicsAnesthesiology TechnologyMultidisciplinaryPhysicslcsh:RPartial pressureModels TheoreticalOxygenChemistrychemistryElectrodeMedicineHigh temporal resolutionlcsh:QBlood Gas Analysis030217 neurology & neurosurgeryResearch ArticlePLoS ONE
researchProduct

A novel technique to follow fast PaO2 variations during experimental CPR

2003

An ultrafast responding fluorescent-quenching PO2 probe allows time-resolved, in vivo measurement of PO2. This study describes several validation experiments of this new device in vitro, and reports its first use during cardiopulmonary resuscitation in an animal model of cardiac arrest.The influence of CO2, temperature and motion artefacts on the signal response of the PO2 probe was analysed in vitro by systematic variation of these values. Thereafter, with approval of the Review Board for the care and use of animals, CPR was performed in four pigs. The PaO2 course was recorded continuously at time resolution of80 ms in the abdominal aorta using an uncoated fluorescence-quenching probe (Fox…

Novel techniquemedicine.medical_specialtySwineDefibrillationPartial Pressuremedicine.medical_treatmentEmergency NursingSignalAnimal modelIn vivoIntensive caremedicineAnimalsFiber Optic TechnologyCardiopulmonary resuscitationFluorescent Dyesbusiness.industryTemperatureTime resolutionEquipment DesignCarbon DioxideCardiopulmonary ResuscitationHeart ArrestSurgeryOxygenDisease Models AnimalEmergency MedicineArtifactsCardiology and Cardiovascular MedicinebusinessBiomedical engineering
researchProduct

A comparison of micropore membrane inlet mass spectrometry–derived pulmonary shunt measurement with riley shunt in a porcine model

2009

The multiple inert gas elimination technique was developed to measure shunt and the ratio of alveolar ventilation to simultaneous alveolar capillary blood flow in any part of the lung (V(A)'/Q') distributions. Micropore membrane inlet mass spectrometry (MMIMS), instead of gas chromatography, has been introduced for inert gas measurement and shunt determination in a rabbit lung model. However, agreement with a frequently used and accepted method for quantifying deficits in arterial oxygenation has not been established. We compared MMIMS-derived shunt (M-S) as a fraction of total cardiac output (CO) with Riley shunt (R-S) derived from the R-S formula in a porcine lung injury model.To allow a …

Pulmonary AtelectasisPulmonary CirculationSwineCapillary actionBlood PressureMass spectrometryVentilation/perfusion ratioMass SpectrometryAdministration InhalationVentilation-Perfusion RatiomedicineAnimalsCardiac OutputChromatographyMultiple inert gas elimination techniquebusiness.industryMicropore FiltersModels CardiovascularMembranes ArtificialLung InjuryBlood flowrespiratory systemOxygenDisease Models AnimalAnesthesiology and Pain MedicineAnesthesiaAnesthetics InhalationLinear ModelsPulmonary shuntGas chromatographyBlood Gas Analysismedicine.symptombusinessShunt (electrical)
researchProduct

Assessment of regional ventilation distribution: comparison of vibration response imaging (VRI) with electrical impedance tomography (EIT)

2013

BACKGROUND: Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. METHODOLOGY/PRINCIPAL FINDINGS: Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) …

Diagnostic ImagingPathologymedicine.medical_specialtyAnatomy and PhysiologyCritical Care and Emergency MedicinePulmonologyVibration Response ImagingSwineRespiratory SystemLung soundlcsh:MedicineVibrationModel OrganismsRespiratory FailureAnesthesiologyBedside TechnologyElectric ImpedancemedicineMedical imagingAnimalsRespiratory Physiologyddc:610lcsh:ScienceTomographyBiologyElectrical impedance tomographyAnesthesiology MonitoringPhysicsAnalysis of VarianceModels StatisticalAnesthesiology TechnologyMultidisciplinarylcsh:RAnimal Modelsrespiratory systemrespiratory tract diseasesPulmonary imagingSpirometryBreathingMedicinelcsh:QTomographyPulmonary VentilationResearch ArticleBiomedical engineering
researchProduct

Ventilation/perfusion ratios measured by multiple inert gas elimination during experimental cardiopulmonary resuscitation

2014

Background During cardiopulmonary resuscitation (CPR) the ventilation/perfusion distribution (VA/Q) within the lung is difficult to assess. This experimental study examines the capability of multiple inert gas elimination (MIGET) to determine VA/Q under CPR conditions in a pig model. Methods Twenty-one anaesthetised pigs were randomised to three fractions of inspired oxygen (1.0, 0.7 or 0.21). VA/Q by micropore membrane inlet mass spectrometry-derived MIGET was determined at baseline and during CPR following induction of ventricular fibrillation. Haemodynamics, blood gases, ventilation distribution by electrical impedance tomography and return of spontaneous circulation were assessed. Inter…

business.industrymedicine.medical_treatmentHemodynamicsGeneral MedicineReturn of spontaneous circulationmedicine.diseaseVentilation/perfusion ratioAnesthesiology and Pain MedicineAnesthesiaVentricular fibrillationmedicinePulmonary shuntCardiopulmonary resuscitationmedicine.symptombusinessPerfusionShunt (electrical)Acta Anaesthesiologica Scandinavica
researchProduct

Influence of respiratory rate and end-expiratory pressure variation on cyclic alveolar recruitment in an experimental lung injury model

2012

Introduction Cyclic alveolar recruitment/derecruitment (R/D) is an important mechanism of ventilator-associated lung injury. In experimental models this process can be measured with high temporal resolution by detection of respiratory-dependent oscillations of the paO2 (ΔpaO2). A previous study showed that end-expiratory collapse can be prevented by an increased respiratory rate in saline-lavaged rabbits. The current study compares the effects of increased positive end-expiratory pressure (PEEP) versus an individually titrated respiratory rate (RRind) on intra-tidal amplitude of Δ paO2 and on average paO2 in saline-lavaged pigs. Methods Acute lung injury was induced by bronchoalveolar lavag…

Time FactorsRespiratory rateSwinePilot ProjectsLung injuryCritical Care and Intensive Care MedicinePositive-Pressure RespirationRandom AllocationRespiratory Ratevarying shunt fractionsAnimalsMedicineddc:610porcine modelcyclic alveolar recruitmentbusiness.industryResearchLung Injuryrespiratory systemrespiratory- dependent paO 2 oscillationsrespiratory tract diseasesPulmonary AlveoliDisease Models Animalacute lung injuryAnesthesiaHigh temporal resolutionIncreased respiratory ratebusinesscirculatory and respiratory physiologyCritical Care
researchProduct

Influence of inspiration to expiration ratio on cyclic recruitment and derecruitment of atelectasis in a saline lavage model of acute respiratory dis…

2015

OBJECTIVE Cyclic recruitment and derecruitment of atelectasis can occur during mechanical ventilation, especially in injured lungs. Experimentally, cyclic recruitment and derecruitment can be quantified by respiration-dependent changes in PaO2 (ΔPaO2), reflecting the varying intrapulmonary shunt fraction within the respiratory cycle. This study investigated the effect of inspiration to expiration ratio upon ΔPaO2 and Horowitz index. DESIGN Prospective randomized study. SETTING Laboratory investigation. SUBJECTS Piglets, average weight 30 ± 2 kg. INTERVENTIONS At respiratory rate 6 breaths/min, end-inspiratory pressure (Pendinsp) 40 cm H2O, positive end-expiratory pressure 5 cm H2O, and FIO2…

Pulmonary AtelectasisRespiratory rateSwinemedicine.medical_treatmentAcute Lung InjuryAtelectasis610 Medicine & healthCritical Care and Intensive Care MedicinePositive-Pressure RespirationRandom AllocationmedicineInverse ratio ventilationAnimalsExpirationProspective StudiesHorowitz indexTherapeutic Irrigation610 Medicine & healthMechanical ventilationRespiratory Distress SyndromeLungbusiness.industrymedicine.diseaseRespiration Artificialmedicine.anatomical_structureInhalationExhalationAnesthesiaBreathingBlood Gas Analysisbusiness
researchProduct

Observation of ventilation-induced Spo(2) oscillations in pigs: first step to noninvasive detection of cyclic recruitment of atelectasis?

2010

High arterial partial oxygen pressure (Pao(2)) oscillations within the respiratory cycle were described recently in experimental acute lung injury. This phenomenon has been related to cyclic recruitment of atelectasis and varying pulmonary shunt fractions. Noninvasive detection of Spo(2) (oxygen saturation measured by pulse oximetry) as an indicator of cyclic collapse of atelectasis, instead of recording Pao(2) oscillations, could be of clinical interest in critical care. Spo(2) oscillations were recorded continuously in three different cases of lung damage to demonstrate the technical feasibility of this approach. To deduce Pao(2) from Spo(2), a mathematical model of the hemoglobin dissoci…

Pulmonary and Respiratory MedicinePulmonary AtelectasisPulmonary CirculationTime FactorsVentilator-associated lung injurySwineClinical BiochemistryAtelectasisLung injuryModels BiologicalHemoglobinsPredictive Value of TestsMedicineAnimalsOximetryPhotoplethysmographyMolecular BiologyOxygen saturation (medicine)Respiratory Distress Syndromemedicine.diagnostic_testbusiness.industryfungiOxygen–haemoglobin dissociation curveOxygenationmedicine.diseaseRespiration ArtificialOxygenPulse oximetryDisease Models AnimalAnesthesiaBreathingRespiratory MechanicsFeasibility StudiesbusinessExperimental lung research
researchProduct

Spatial and temporal heterogeneity of ventilator-associated lung injury after surfactant depletion.

2008

Volutrauma and atelectrauma have been proposed as mechanisms of ventilator-associated lung injury, but few studies have compared their relative importance in mediating lung injury. The objective of our study was to compare the injury produced by stretch (volutrauma) vs. cyclical recruitment (atelectrauma) after surfactant depletion. In saline-lavaged rabbits, we used high tidal volume, low respiratory rate, and low positive end-expiratory pressure to produce stretch injury in nondependent lung regions and cyclical recruitment in dependent lung regions. Tidal changes in shunt fraction were assessed by measuring arterial Po2 oscillations. After ventilating for times ranging from 0 to 6 h, lu…

Pathologymedicine.medical_specialtyVentilator-associated lung injuryPhysiologyNitric Oxide Synthase Type IIInflammationEnzyme-Linked Immunosorbent AssayPulmonary EdemaRespiratory physiologyLung injuryPhysiology (medical)medicineAnimalsInterleukin 8LungChemokine CCL2PeroxidaseLungVentilators Mechanicalbusiness.industryRespiratory diseaseInterleukin-8Pulmonary SurfactantsLung Injuryrespiratory systemmedicine.diseasePulmonary edemarespiratory tract diseasesOxygenmedicine.anatomical_structureNeutrophil InfiltrationCalibrationRespiratory MechanicsCytokinesFluid TherapyFemaleRabbitsmedicine.symptomBlood Gas AnalysisChemokinesbusinessJournal of applied physiology (Bethesda, Md. : 1985)
researchProduct