Multi frequency phase fluorimetry (MFPF) for oxygen partial pressure measurement: ex vivo validation by polarographic clark-type electrode.

2013

BACKGROUND: Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. METHODOLOGY/PRINCIPAL FINDINGS: MFPF technology was first investigated in N = 8 anaesthetised pigs at FIO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each FIO2 level, blood samples were withdrawn and PO2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-PO2 readings were compared to CTE in an artificial circulatory s…

Drugs and DevicesAnatomy and PhysiologyMaterials scienceSwinePartial PressurePhase (waves)Analytical chemistrychemistry.chemical_elementlcsh:Medicine610 Medicine & healthBioengineeringCardiovascularCardiovascular SystemOxygenFluorescence spectroscopyMedical Devices03 medical and health sciencesEngineering0302 clinical medicineAnesthesiologyDiagnostic MedicineAnimalsFluorometryddc:610030212 general & internal medicine610 Medicine & healthlcsh:ScienceBiologyBlood gas analysisPolarographyChemical PhysicsAnesthesiology TechnologyMultidisciplinaryPhysicslcsh:RPartial pressureModels TheoreticalOxygenChemistrychemistryElectrodeMedicineHigh temporal resolutionlcsh:QBlood Gas Analysis030217 neurology & neurosurgeryResearch ArticlePLoS ONE
researchProduct

A comparison of micropore membrane inlet mass spectrometry–derived pulmonary shunt measurement with riley shunt in a porcine model

2009

The multiple inert gas elimination technique was developed to measure shunt and the ratio of alveolar ventilation to simultaneous alveolar capillary blood flow in any part of the lung (V(A)'/Q') distributions. Micropore membrane inlet mass spectrometry (MMIMS), instead of gas chromatography, has been introduced for inert gas measurement and shunt determination in a rabbit lung model. However, agreement with a frequently used and accepted method for quantifying deficits in arterial oxygenation has not been established. We compared MMIMS-derived shunt (M-S) as a fraction of total cardiac output (CO) with Riley shunt (R-S) derived from the R-S formula in a porcine lung injury model.To allow a …

Pulmonary AtelectasisPulmonary CirculationSwineCapillary actionBlood PressureMass spectrometryVentilation/perfusion ratioMass SpectrometryAdministration InhalationVentilation-Perfusion RatiomedicineAnimalsCardiac OutputChromatographyMultiple inert gas elimination techniquebusiness.industryMicropore FiltersModels CardiovascularMembranes ArtificialLung InjuryBlood flowrespiratory systemOxygenDisease Models AnimalAnesthesiology and Pain MedicineAnesthesiaAnesthetics InhalationLinear ModelsPulmonary shuntGas chromatographyBlood Gas Analysismedicine.symptombusinessShunt (electrical)
researchProduct

Review of Particle Physics

2020

The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 2,143 new measurements from 709 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, …

high energyleptonmixing [neutrino]High Energy Physics::LatticeCosmic microwave backgrounddiffractionTechnicolorAstrophysicsOmega01 natural sciencesPhysics Particles & Fieldshiggs-boson productionBig Bang nucleosynthesiscosmological model: parameter spacetaudark energyMonte CarlofieldspentaquarkinstrumentationSettore FIS/01gauge bosonAnomalous magnetic dipole momentdeep-inelastic scatteringnew physicsPhysicsDOUBLE-BETA-DECAYElectroweak interactiondensity [dark matter]HEAVY FLAVOURQuarkoniumreview; particle; physicsSUPERSYMMETRIC STANDARD MODELsquare-root-sPhysics Nucleargrand unified theoryboson: heavystatisticsPhysical SciencesHiggs bosonaxion: massflavor: violationNeutrinoELECTROWEAK SYMMETRY-BREAKINGnumerical calculations: Monte Carlophysicson-lineS013EPHQuarkheavy [boson]particle[PHYS.NUCL]Physics [physics]/Nuclear Theory [nucl-th]Physics Multidisciplinaryanomalous magnetic-momentelectroweak radiative-correctionsdark matter: densityHiggs particlemesonneutrino masses neutrino mixing; neutrino oscillations114 Physical sciencesCHIRAL PERTURBATION-THEORYneutrino mixingStandard Modelquark0202 Atomic Molecular Nuclear Particle And Plasma PhysicsNucleosynthesisquantum chromodynamicsCP: violationDark matterddc:530particle physicsStrong Interactions010306 general physicssparticleS013DFgrand unified theoriesPRODUCTIONGauge bosonScience & Technologyneutrino oscillationsneutrino masses010308 nuclear & particles physicsC50 Other topics in experimental particle physicsParticle Data GroupAstronomy and AstrophysicsDeep inelastic scatteringto-leading-order* Automatic Keywords *heavy bosonaxiontables (particle physics)Tetraquarkproton-proton collisionsSupersymmetryhadronneutrino: mixing[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]cosmologyVolume (compression)HIGGS-BOSONUB-VERTICAL-BARcosmological modeldark energy densityexperimental methodsddc:539.72021Physics beyond the Standard Modelstandard modelgroup theoryGeneral Physics and Astronomytables particle physicshigh energy physics[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Quantum chromodynamicsPhysicsenergy: highE Rev 2016[PHYS.HTHE]Physics [physics]/High Energy Physics - Theory [hep-th]Settore FIS/01 - Fisica SperimentalephotonSupersymmetryNuclear & Particles Physicsparameter space [cosmological model]dark energy: densityhigh [energy]M013WXfermion-pair productionNuclear and High Energy PhysicsParticle physicsHiggs bosonreviewAstrophysics::Cosmology and Extragalactic AstrophysicsAstronomy & Astrophysics530dark matterstatistical analysisDouble beta decay0103 physical sciencesconservation lawcold dark-matterTAU LEPTONSAstrophysics::Galaxy AstrophysicstablesDEEP-INELASTIC-SCATTERINGelectroweak interactionHigh Energy Physics::Phenomenology750 GeV diphoton excessPRODUCTION CROSS-SECTIONbaryondensity [dark energy]Physics and AstronomygravitationCKM matrix[PHYS.HPHE]Physics [physics]/High Energy Physics - Phenomenology [hep-ph]High Energy Physics::ExperimentsupersymmetryMinimal Supersymmetric Standard Model
researchProduct

Observation of ventilation-induced Spo(2) oscillations in pigs: first step to noninvasive detection of cyclic recruitment of atelectasis?

2010

High arterial partial oxygen pressure (Pao(2)) oscillations within the respiratory cycle were described recently in experimental acute lung injury. This phenomenon has been related to cyclic recruitment of atelectasis and varying pulmonary shunt fractions. Noninvasive detection of Spo(2) (oxygen saturation measured by pulse oximetry) as an indicator of cyclic collapse of atelectasis, instead of recording Pao(2) oscillations, could be of clinical interest in critical care. Spo(2) oscillations were recorded continuously in three different cases of lung damage to demonstrate the technical feasibility of this approach. To deduce Pao(2) from Spo(2), a mathematical model of the hemoglobin dissoci…

Pulmonary and Respiratory MedicinePulmonary AtelectasisPulmonary CirculationTime FactorsVentilator-associated lung injurySwineClinical BiochemistryAtelectasisLung injuryModels BiologicalHemoglobinsPredictive Value of TestsMedicineAnimalsOximetryPhotoplethysmographyMolecular BiologyOxygen saturation (medicine)Respiratory Distress Syndromemedicine.diagnostic_testbusiness.industryfungiOxygen–haemoglobin dissociation curveOxygenationmedicine.diseaseRespiration ArtificialOxygenPulse oximetryDisease Models AnimalAnesthesiaBreathingRespiratory MechanicsFeasibility StudiesbusinessExperimental lung research
researchProduct

Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.

2009

BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP …

AdultMaleFluid responsivenessBlood PressureAutomationMonitoring IntraoperativeAbdomenMedicineHumansIn patientPulseAgedObserver VariationBlood Volumebusiness.industryAirway ResistanceLimits of agreementReproducibility of ResultsMiddle AgedReference StandardsPulse pressureAnesthesiology and Pain MedicineBlood pressureData Interpretation StatisticalRespiratory MechanicsFemalebusinessAlgorithmAlgorithmsAnesthesia and analgesia
researchProduct