Relative luminosity measurement of the LHC with the ATLAS forward calorimeter

In this paper it is shown that a measurement of the relative luminosity changes at the LHC may be obtained by analysing the currents drawn from the high voltage power supplies of the electromagnetic section of the forward calorimeter of the ATLAS detector. The method was verified with a reproduction of a small section of the ATLAS forward calorimeter using proton beams of known beam energies and variable intensities at the U-70 accelerator at IHEP in Protvino, Russia. The experimental setup and the data taking during a test beam run in April 2008 are described in detail. A comparison of the measured high voltage currents with reference measurements from beam intensity monitors shows a linea…

research product

Evaluation of the local hadronic calibration with combined beam-test data for the endcap and forward calorimeters of ATLAS in the pseudorapidity region

Abstract The local hadronic calibration scheme developed for the reconstruction and calibration of jets and missing transverse energy in ATLAS has been evaluated using data obtained during combined beam tests of modules of the ATLAS liquid argon endcap and forward calorimeters. These tests covered the pseudorapidity range of 2.5 | η | 4.0 . The analysis has been performed using special sets of calibration weights and corrections obtained with the G eant 4 simulation of a detailed beam-test setup. The evaluation itself has been performed through the careful study of specific calorimeter performance parameters such as e.g. energy response and resolution, shower shapes, as well as different ph…

research product

Performance of the ATLAS liquid argon endcap calorimeter in the pseudorapidity region in beam tests

Abstract The pseudorapidity region 2.5 | η | 4.0 in ATLAS is a particularly complex transition zone between the endcap and forward calorimeters. A set-up consisting of 1 4 resp. 1 8 of the full azimuthal acceptance of the ATLAS liquid argon endcap and forward calorimeters has been exposed to beams of electrons, pions and muons in the energy range E ⩽ 200 GeV at the CERN SPS. Data have been taken in the endcap and forward calorimeter regions as well as in the transition region. This beam test set-up corresponds very closely to the geometry and support structures in ATLAS. A detailed study of the performance in the endcap and forward calorimeter regions is described. The data are compared wit…

research product

Liquid argon calorimeter performance at high rates

Abstract We project the performance of the ATLAS liquid argon endcap and forward calorimeters at the planned high luminosity LHC option HL-LHC by exposing small calorimeter modules of the electromagnetic, hadronic, and forward calorimeters to high intensity beams at IHEP/Protvino. The beam intensity extends well beyond the maximum expected for these calorimeters at HL-LHC. The signal reconstruction and calorimeter performance have been studied in full detail.