0000000000211537

AUTHOR

Elena Riad Deglow

showing 3 related works from this author

Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Navigation for Dental Implant Placement: An In Vitro Study

2019

Aim: To analyze the accuracy capability of two computer-aided navigation procedures for dental implant placement. Materials and Methods: A total of 40 dental implants were selected, which were randomly distributed into two study groups, namely, group A, consisting of those implants that were placed using a computer-aided static navigation system (n = 20) (guided implant (GI)) and group B, consisting of those implants that were placed using a computer-aided dynamic navigation system (n = 20) (navigation implant (NI)). The placement of the implants from group A was performed using surgical templates that were designed using 3D implant-planning software based on preoperative cone-beam computed…

image-guided surgerymedicine.medical_treatmentArticle03 medical and health sciences0302 clinical medicineSoftware0502 economics and businessimplantologymedicineHardware_INTEGRATEDCIRCUITSComputerSystemsOrganization_SPECIAL-PURPOSEANDAPPLICATION-BASEDSYSTEMSDental implantOrthodonticsComputer-assisted surgeryreal-time trackingbusiness.industry05 social sciencesNavigation system030206 dentistryGeneral Medicinecomputer-assisted surgeryImage-guided surgeryCoronal planeComputer-aidednavigation system050211 marketingImplantbusinessJournal of Clinical Medicine
researchProduct

Influence of Drilling Technique on the Radiographic, Thermographic, and Geomorphometric Effects of Dental Implant Drills and Osteotomy Site Preparati…

2020

The aim of this comparative study is to analyze the influence of drilling technique on the radiographic, thermographic, and geomorphometric effects of dental implant drills and osteotomy site preparations. One hundred and twenty osteotomy site preparations were performed on sixty epoxy resin samples using three unused dental implant drill systems and four drilling techniques performed with a random distribution into the following study groups: Group A: drilling technique performed at 800 rpm with irrigation (n = 30)

musculoskeletal diseasesOsteotomy siteCone beam computed tomographymedicine.medical_treatmentRadiographyeducationlcsh:MedicineOsteotomyArticle03 medical and health sciences0302 clinical medicineotorhinolaryngologic diseasesmedicineheat generationdrill coolingDental implantOrthodonticsDrillbusiness.industrylcsh:RDrilling030206 dentistryGeneral Medicinedental implants drillsequipment and supplieslow drilling speed030220 oncology & carcinogenesisHeat generationbusinessosteotomyJournal of Clinical Medicine
researchProduct

Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Procedure for Endodontic Access Cavities: An In Vitro Study

2020

: Purpose: To analyze the accuracy of two computer-aided navigation techniques to guide the performance of endodontic access cavities compared with the conventional access procedure. Materials and Methods: A total of 30 single-rooted anterior teeth were selected, which were randomly distributed into three study groups: Group A&mdash

Study groupsmedicine.medical_specialtylcsh:MedicineComputed tomographyArticleendodontic access cavity03 medical and health sciences0302 clinical medicinemedicineIn vitro studyAnterior teeth030304 developmental biologyOrthodontics0303 health sciencesreal-time trackingmedicine.diagnostic_testbusiness.industrylcsh:RNavigation system030206 dentistryGeneral MedicineEndodonticscomputer-assisted treatmentimage-guided treatmentendodonticsCoronal planeComputer-aidednavigation systembusinessJournal of Clinical Medicine
researchProduct