0000000000214377

AUTHOR

Gabriel Vivó-truyols

Resolution assessment and performance of several organic modifiers in hybrid micellar liquid chromatography

The performance of four criteria that measure the elementary resolution (modified selectivity, modified RS, peak purity, and orthogonal valley-to-peak ratio) was critically assessed using as global resolution function, the product of elementary measurements. The peak purities and valley-to-peak criteria yielded the best description of the overall separation according to the shape of the resolution surfaces compared to the peak arrangements in the chromatograms, the capability of defining unambiguously the composition regions of complete resolution, and the resolution achieved in the predicted optimums. Peak purities were used to compare the effect of five organic modifiers (1-propanol, 1-bu…

research product

Towards unsupervised analysis of second-order chromatographic data: automated selection of number of components in multivariate curve-resolution methods.

A method to apply multivariate curve-resolution unattendedly is presented. The algorithm is suitable to perform deconvolution of two-way data (e.g. retrieving the individual elution profiles and spectra of co-eluting compounds from signals obtained from a chromatograph equipped with multiple-channel detection: LC-DAD or GC-MS). The method is especially adequate to achieve the advantages of deconvolution approaches when huge amounts of data are present and manual application of multivariate techniques is too time-consuming. The philosophy of the algorithm is to mimic the reactions of an expert user when applying the orthogonal projection approach--multivariate curve-resolution techniques. Ba…

research product

Program for the interpretive optimization of two-dimensional resolution.

The challenge of fully optimizing LC × LC separations is horrendous. Yet, it is essential to address this challenge if sophisticated LC × LC instruments are to be utilized to their full potential in an efficient manner. Currently, lengthy method development is a major obstacle to the proliferation of the technique, especially in industry. A program was developed for the rigorous optimization of LC × LC separations, using gradient-elution in both dimensions. The program establishes two linear retention models (one for each dimension) based on just two LC × LC experiments. It predicts LC × LC chromatograms using a simple van-Deemter model to generalize band-broadening. Various objectives (ana…

research product