0000000000214566

AUTHOR

F. Knitz

Ein Auswerteprogramm zur quantitativen Untersuchung der Lungenventilation mittels dynamischer MRT von hochpolarisiertem 3He

Purpose: 3 He-MRI is able to visualize the regional distribution of lung ventilation with a temporal and spatial resolution so far unmatched by any other technique. The aim of the study was the development of a new software tool for quantification of dynamic ventilation parameters in absolute physical units. Materials and Methods: During continuous breathing, a bolus of hyperpolarized 3 He (300 ml) was applied at inspiration and a series of 168 coronal projection images simultaneously acquired using a 2D FLASH-sequence. Postprocessing software was developed to analyze the 3 He distribution in the lung. After correction for lung motion, several ventilation parameters (rise time, delay time, …

research product

Reformatierungen als Lösungsansatz für die Problematik der unterschiedlichen Schichtführung beim Vergleich von3He-MRT und HR-CT der Lunge

Purpose: 3 He-MRI of the lung has been shown to be a sensitive method for functional imaging of the lung. A previous study compared 3 He-MRI (coronal planes) with CT (transverse planes) by looking for ventilation defects and their pathomorphologic correlation. Anatomic structures, such as lobar fissures and hilar vessels, were used for orientation, but the reliable assignment of ventilation defects to lung segments is problematic. The present work compares multiplanar reformations of 3 He-MRI and HR-CT, which were generated from planes determined by the respective method, and investigates their suitability as a solution of this problem. Materials and Methods: A total of 16 data sets taken f…

research product