0000000000235546
AUTHOR
L. Herreros-chavez
Direct determination by portable ED-XRF of mineral profile in cocoa powder samples
Abstract The present study has exploited the rapidity of the analysis and the multi-elemental capability of the energy dispersive X- ray fluorescence (ED-XRF) technique for the mineral profile determination in cocoa powder. A fast, cheap and environmental sustainable method without reagent consumption or toxic waste generation has been proposed. The samples can be prepared in the form of pellets of 13 mm in diameter and 2–3 mm thickness. The different internal calibrations used by ED-XRF equipment did not provide accurate results when comparing the mineral profile with the concentration obtained by Inductively Couple Plasma Optical Emission Spectroscopy (ICP-OES) after microwave assisted di…
Green methodology for quality control of elemental content of infant milk powder
Abstract A green methodology for the direct determination of elemental content in infant milk powder samples from 0 to 3 years was developed. A portable energy dispersive X-ray fluorescence (ED-XRF) tool has been used as a direct method for the quantification of five essential elements (Ca, K, Fe, Cu and Zn). For analysis pellets from 0.8 g of each sample weight were made and analyzed. Due to the high dependence of the ED-XRF signal with the sample matrix, external calibrations using cocoa powder diluted with glucose were performed. Infant milk samples were diluted with lactose and the signals were interpolated in the external calibrations. Concentrations obtained by ED-XRF were compared wi…
Partial least squares modelization of energy dispersive X-ray fluorescence.
As a proof of concept, a green methodology has been developed for the energy dispersive X-ray fluorescence (ED-XRF) determination of calcium, potassium, iron, magnesium, aluminum, chromium, strontium, phosphorus and nickel in the peel of untreated kaki fruit (Diospyros kaki. L) samples. ED-XRF spectra of fifty-six kakis purchased in the local area of LLombay (Valencia) were obtained directly from samples without any previous treatment and without sample damage just after cleaning the fruit with distilled water. Inductively Couple Plasma Optical Emission Spectrometry (ICP-OES) was used as a reference method to determine the mineral elements after microwave assisted acid digestion. XRF spectr…
Mineral profiles of legumes and fruits through partial least squares energy dispersive X-ray fluorescence
Abstarct Energy dispersive X-ray fluorescence (ED-XRF) has been employed for the determination of mineral elements in 15 varieties of legumes and 14 cherry samples. ED-XRF signals directly obtained from pulverized samples were modelized by partial least squares (PLS) using Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) of a selected number of samples, after microwave assisted acid digestion, as reference data. Models were built to predict the concentration of Al, Ca, Cu, Fe, K, Mg, P, Sr and Zn. Average concentrations predicted were 6, 930, 7, 40, 6400, 990, 2100, 4 and 15 μg g−1 for Al, Ca, Cu, Fe, K, Mg, P, Sr and Zn, respectively with relative errors from 7 till 26%. …