Diego Montagud-martínez

Optical performance of a new design of trifocal intraocular lens based on the Devil's diffractive lens

In this work, we propose a new diffractive trifocal intraocular lens design with focus extension, conceived to provide a high visual performance at intermediate distances. This design is based on a fractal structure known as the "Devil's staircase". To assess its optical performance, numerical simulations have been performed with a ray tracing program using the Liou-Brennan model eye under polychromatic illumination. The simulated through the focus visual acuity was the merit function employed to test its pupil-dependence and its behavior against decentering. A qualitative assessment of the multifocal intraocular lens (MIOL) was also performed experimentally with an adaptive optics visual s…

research product

Imaging Performance of a Diffractive Corneal Inlay for Presbyopia in a Model Eye

[EN] In this work we evaluated the imaging properties of the Diffractive Corneal Inlay (DCI), a novel type of corneal implant working by diffraction that we proposed for the treatment of presbyopia. ZEMAX OpticStudio software was employed for the numerical assessment, with simulations performed in a human-based eye model. In the ray tracing analysis, we used the Modulation Transfer Function (MTF), the Area under the MTF (AMTF), and the Point Spread Function (PSF). The theoretical performance of the DCI under different situations was evaluated in comparison with a commercially available pinhole based corneal inlay. Finally, real images were obtained experimentally in vitro in a model eye wit…

research product

Optical Evaluation of New Designs of Multifocal Diffractive Corneal Inlays

[EN] Purpose. To assess the imaging properties of two different designs of a new concept of corneal inlays whose working principle is based on diffraction. Methods. The quality of the retinal images provided by Diffractive Corneal Inlays (DCIs) was evaluated theoretically in comparison with Small Aperture Corneal Inlay (SACI). ZEMAX OpticStudio software was employed for the simulations in an eye model with different pupil diameters (3.0 mm and 4.5 mm). The employed merit functions in the analysis were the Modulation Transfer Function (MTF), the area under the MTF (MTFa), and the Point Spread Function (PSF). Comparison was made with the SACI at different defocus conditions. Results. The bifo…

research product

A new trifocal corneal inlay for presbyopia

[EN] Corneal inlays (CIs) are the most recent surgical procedure for the treatment of presbyopia in patients who want complete independence from the use of glasses or contact lenses. Although refractive surgery in presbyopic patients is mostly performed in combination with cataract surgery, when the implantation of an intraocular lens is not necessary, the option of CIs has the advantage of being minimally invasive. Current designs of CIs are, either: small aperture devices, or refractive devices, however, both methods do not have good performance simultaneously at intermediate and near distances in eyes that are unable to accommodate. In the present study, we propose the first design of a …

research product

Proposal of a new diffractive corneal inlay to improve near vision in a presbyopic eye

[EN] A new class of diffraction-based corneal inlays for treatment of presbyopia is described. The inlay is intended to achieve an improvement of the near focus quality over previous designs. Our proposal is a two-zone hybrid device with separated amplitude and phase areas having a central aperture and no refractive power. An array of micro-holes is distributed on the surface of the inlay conforming a binary photon sieve. In this way, the central hole of the disk contributes to the zero order of diffraction, and the light diffracted by the micro-holes in the peripheral photon sieve produces a real focus for near vision. We employed ray-tracing software to study the performance of the new in…

research product