0000000000248558

AUTHOR

C.n. Novoa-parra

showing 2 related works from this author

Metacarpophalangeal joint of the thumb arthrodesis using intramedullary interlocking screws XMCP™

2018

Abstract The study objective was to assess the results of a thumb metacarpophalangeal joint (MCPJ) arthrodesis using intramedullary interlocking screws at 25°, XMCP ™ (Extremity Medical, Parsippany, NJ). Radiographs evaluated the angle of arthrodesis, time of fusion and fixation of the implant. Clinical and functional outcomes were assessed using the DASH questionnaire and the VAS scale. Any complications found during surgery or the follow-up period were noted. We studied 9 patients. The mean follow-up was 27.6 months. Patients showed clinical and radiological evidence of fusion in an average of 8 weeks, the angle of fusion was 25°. There were no complications and no implant had to be remov…

MaleArthrodesismedicine.medical_treatmentRadiographyBone ScrewsArthrodesisThumblaw.inventionArthritis RheumatoidMetacarpophalangeal JointIntramedullary rod03 medical and health sciencesFixation (surgical)0302 clinical medicinelawmedicineHumansOrthopedics and Sports Medicine030212 general & internal medicineAgedOrthodontics030222 orthopedicsbusiness.industryArthrodesis Arthrosis Articulación metacarpofalángica Artritis reumatoide Artrodesis Artrosis Metacarpophalangeal joint Rheumatoid arthritisMetacarpophalangeal jointMiddle AgedTreatment Outcomemedicine.anatomical_structureThumbRadiological weaponFemaleSurgeryImplantJoint DiseasesbusinessFollow-Up StudiesRevista Española de Cirugía Ortopédica y Traumatología (English Edition)
researchProduct

Artrodesis de la articulación metacarpofalángica del pulgar con tornillos intramedulares entrelazados de ángulo fijo XMCP™

2018

Resumen El objetivo de estudio fue valorar el resultado de la artrodesis de la articulacion metacarpofalangica del pulgar mediante el sistema de tornillos intramedulares de angulo fijo a 25°, XMCP™ (Extremity Medical, Parsippany, NJ). En las radiografias se evaluo el angulo de artrodesis, el tiempo de fusion osea y fijacion del implante. Los resultados clinicos y funcionales se evaluaron mediante el cuestionario DASH y la escala EVA. Se observo cualquier complicacion encontrada durante la cirugia o el periodo de seguimiento. Se estudiaron 9 pacientes. El seguimiento medio fue de 27,6 meses. Los pacientes presentaron evidencia clinica y radiologica de fusion en un promedio de 8 semanas, y el…

030222 orthopedics03 medical and health sciences0302 clinical medicineOrthopedics and Sports MedicineSurgery030212 general & internal medicineRevista Española de Cirugía Ortopédica y Traumatología
researchProduct