0000000000249624

AUTHOR

Alain Rouleau

Immuno-MALDI-MS in Human Plasma and on-Chip Biomarker Characterizations at the Femtomole Level

Immuno-SPR-MS is the combination of immuno-sensors in biochip format with mass spectrometry. This association of instrumentation allows the detection and the quantification of proteins of interest by SPR and their molecular characterization by additional MS analysis. However, two major bottlenecks must be overcome for a wide diffusion of the SPR-MS analytical platform: (i) To warrant all the potentialities of MS, an enzymatic digestion step must be developed taking into account the spot formats on the biochip and (ii) the biological relevancy of such an analytical solution requires that biosensing must be performed in complex media. In this study, we developed a procedure for the detection …

research product

Technological innovation around protein and cell biochip for diagnosis: a translational research from nanoworld to patient

International audience; A great challenge in biosensors and diagnosis devices relies on the way to reconstitute relevant biological mechanisms on surface of the biochips and which analytical tools are convenient to provide accurate and rapid information on the structures and function of molecules attached to this surface. A better control in the realization of biochips can be obtained in combining different complementary approaches while always keeping in mind the biological key point. Researches in CLIPP are focused towards this objective. Conception, realization and characterization of protein and cell chips are presented. We detail different strategies of materials engineering1,2,3, chem…

research product

Revisited BIA-MS combination: Entire "on-a-chip" processing leading to the proteins identification at low femtomole to sub-femtomole levels

International audience; We present the results of a study in which biomolecular interaction analysis (BIA, Biacore 2000) was combined with mass spectrometry (MS) using entire "on-a-chip" procedure. Most BIA-MS studies included an elution step of the analyte prior MS analysis. Here, we report a low-cost approach combining Biacore analysis with homemade chips and MS in situ identification onto the chips without elution step. First experiments have been made with rat serum albumin to determine the sensitivity and validation of the concept has been obtained with an antibody/antigen couple. Our "on-a-chip" procedure allowed complete analysis by MS-MS of the biochip leading to protein identificat…

research product