0000000000249730

AUTHOR

Samuel Ayet San Andrés

showing 7 related works from this author

Separation of atomic and molecular ions by ion mobility with an RF carpet

2021

Gas-filled stopping cells are used at accelerator laboratories for the thermalization of high-energy radioactive ion beams. Common challenges of many stopping cells are a high molecular background of extracted ions and limitations of extraction efficiency due to space-charge effects. At the FRS Ion Catcher at GSI, a new technique for removal of ionized molecules prior to their extraction out of the stopping cell has been developed. This technique utilizes the RF carpet for the separation of atomic ions from molecular contaminant ions through their difference in ion mobility. Results from the successful implementation and test during an experiment with a 600~MeV/u $^{124}$Xe primary beam are…

low-energy RIBPhysics - Instrumentation and DetectorsOrders of magnitude (temperature)beam purificationFOS: Physical sciences010402 general chemistrynucl-ex01 natural sciences530Ionmenetelmätion mobilityIonizationMoleculeddc:530Physical and Theoretical ChemistryfysiikkaNuclear Experiment (nucl-ex)Nuclear ExperimentInstrumentationphysics.ins-detSpectroscopyIon transporterRange (particle radiation)ionitChemistry010401 analytical chemistryExtraction (chemistry)gas cellpuhdistusInstrumentation and Detectors (physics.ins-det)Condensed Matter Physics0104 chemical sciencesmolecular contaminationBeamlinespace chargeAtomic physicserottaminen (tekniikka)epäpuhtaudet
researchProduct

A Novel Method for the Measurement of Half-Lives and Decay Branching Ratios of Exotic Nuclei

2019

A novel method for simultaneous measurement of masses, Q-values, isomer excitation energies, half-lives and decay branching ratios of exotic nuclei has been demonstrated. The method includes first use of a stopping cell as an ion trap, combining containment of precursors and decay-recoils for variable durations in a cryogenic stopping cell (CSC), and afterwards the identification and counting of them by a multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS). Feasibility has been established by recording the decay and growth of $^{216}$Po and $^{212}$Pb (alpha decay) and of $^{119m2}$Sb (t$_{1/2}$ = 850$\pm$90 ms) and $^{119g}$Sb (isomer transition), obtaining half-lives and bran…

PhysicsNuclear and High Energy Physics010308 nuclear & particles physicsFOS: Physical sciencesdecay branching ratiosBranching (polymer chemistry)Mass spectrometry01 natural sciences530half-livesexotic nuclei0103 physical sciencesddc:530novel methodmeasurementIon trapAlpha decayAtomic physicsNuclear Experiment (nucl-ex)Nuclear Experimentydinfysiikka010306 general physicsNuclear ExperimentExcitation
researchProduct

Mass and half-life measurements of neutron-deficient iodine isotopes

2020

The European physical journal / A 56(5), 143 (2020). doi:10.1140/epja/s10050-020-00153-5

Nuclear and High Energy PhysicsALPHA-DECAYSEPARATORMass spectrometry01 natural sciences530Ionjodi0103 physical sciencesNuclear fusionNeutronddc:530010306 general physicsNuclear ExperimentPhysicsisotoopitIsotope010308 nuclear & particles physicsPERFORMANCESPECTROMETRYQuadrupoleFRS; PROJECTILEAlpha decayAtomic physicsydinfysiikkaGround stateSYSTEM
researchProduct

Removal of molecular contamination in low-energy RIBs by the isolation-dissociation-isolation method

2020

Nuclear instruments & methods in physics research / B 463, 324 - 326 (2020). doi:10.1016/j.nimb.2019.04.072

low-energy RIBNuclear and High Energy PhysicsMaterials scienceCollision-induced dissociationbeam purificationtutkimuslaitteet53001 natural sciencesDissociation (chemistry)RF-quadrupolelaw.inventionIonlawDipole magnet0103 physical sciencesddc:530Instrumentation010308 nuclear & particles physics010401 analytical chemistryContaminationSynchrotronIon source0104 chemical sciencesmolecular contaminationBeamlinecollision-induced dissociationPhysics::Accelerator PhysicsAtomic physicsydinfysiikkaNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

High-resolution, accurate multiple-reflection time-of-flight mass spectrometry for short-lived, exotic nuclei of a few events in their ground and low…

2019

Physical review / C covering nuclear physics 99(6), 064313 (2019). doi:10.1103/PhysRevC.99.064313

massaspektrometriaProtonResolution (mass spectrometry)FissionBinding energyMass spectrometrynucl-ex01 natural sciences530binding energy and massesnuclear bindingNuclear physics0103 physical sciencesNeutronddc:530NuclideNuclear Experiment010306 general physicsphysics.ins-detPhysicsbeam diagnostics010308 nuclear & particles physicsnuclear fragmentationlifetimes and widthsTime-of-flight mass spectrometryisomer decaysydinfysiikka
researchProduct

Studying Gamow-Teller transitions and the assignment of isomeric and ground states at $N=50$

2022

Direct mass measurements of neutron-deficient nuclides around the N=50 shell closure below $^{100}$Sn were performed at the FRS Ion Catcher (FRS-IC) at GSI, Germany. The nuclei were produced by projectile fragmentation of $^{124}$Xe, separated in the fragment separator FRS and delivered to the FRS-IC. The masses of 14 ground states and two isomers were measured with relative mass uncertainties down to 1×10−7 using the multiple-reflection time-of-flight mass spectrometer of the FRS-IC, including the first direct mass measurements of $^{98}$Cd and $^{97}$Rh. A new QEC=5437±67 keV was obtained for $^{98}$Cd, resulting in a summed Gamow-Teller (GT) strength for the five observed transitions (0+…

nuclear isomersNuclear and High Energy PhysicsMultiple-reflection time-of-flight massNuclear shell structuremultiple-reflection time-of-flight mass[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]N = 50 isotonesFOS: Physical sciencesGamow-Teller transition?s strength114 Physical sciencesSpectrometerexotic nucleiGamow-Teller transition's strengthnuclear shell structureNuclear isomersspectrometerN=50 isotonesNuclear Experiment (nucl-ex)ydinfysiikkaNuclear ExperimentExotic nuclei
researchProduct

The science case of the FRS Ion Catcher for FAIR Phase-0

2019

The FRS Ion Catcher at GSI enables precision experiments with thermalized projectile and fission fragments. At the same time it serves as a test facility for the Low-Energy Branch of the Super-FRS at FAIR. The FRS Ion Catcher has been commissioned and its performance has been characterized in five experiments with 238U and 124Xe projectile and fission fragments produced at energies in the range from 300 to 1000 MeV/u. High and almost element-independent efficiencies for the thermalization of short-lived nuclides produced at relativistic energies have been obtained. High-accuracy mass measurements of more than 30 projectile and fission fragments have been performed with a multiple-reflection…

ydinreaktiotMR-TOF-MSNuclear Theorymass measurementsddc:530exotic nuclidesNuclear Experimentydinfysiikkanuclear reactionsbeta-delayed neutron emissionemissio (fysiikka)
researchProduct