0000000000262217
AUTHOR
M. Gómez Rodríguez De La Paz
Particle tracking in kaon electroproduction with cathode-charge sampling in multi-wire proportional chambers
Abstract Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the background rate in the chambers. One way to determine the track of a charged particle through a multi-wire proportional chamber (MWPC) is the measurement of the charge distribution induced on its cathodes. In practical applications of this read-out method, the algorithm to relate the measured charge distribution to the avalanche position is an important factor for the achievable position resolution and for the track reconstruction efficiency. An al…
Search at the Mainz Microtron for light massive gauge bosons relevant for the muon g-2 anomaly.
A massive, but light, Abelian U(1) gauge boson is a well-motivated possible signature of physics beyond the standard model of particle physics. In this Letter, the search for the signal of such a U(1) gauge boson in electron-positron pair production at the spectrometer setup of the A1 Collaboration at the Mainz Microtron is described. Exclusion limits in the mass range of 40 MeV/c^{2} to 300 MeV/c^{2}, with a sensitivity in the squared mixing parameter of as little as ε^{2}=8×10^{-7} are presented. A large fraction of the parameter space has been excluded where the discrepancy of the measured anomalous magnetic moment of the muon with theory might be explained by an additional U(1) gauge …
High-Precision Determination of the Electric and Magnetic Form Factors of the Proton
New precise results of a measurement of the elastic electron-proton scattering cross section performed at the Mainz Microtron MAMI are presented. About 1400 cross sections were measured with negative four-momentum transfers squared up to Q^2=1 (GeV/c)^2 with statistical errors below 0.2%. The electric and magnetic form factors of the proton were extracted by fits of a large variety of form factor models directly to the cross sections. The form factors show some features at the scale of the pion cloud. The charge and magnetic radii are determined to be r_E=0.879(5)(stat.)(4)(syst.)(2)(model)(4)(group) fm and r_M=0.777(13)(stat.)(9)(syst.)(5)(model)(2)(group) fm.
In-beam tests of scintillating fibre detectors at MAMI and at GSI
The performance of scintillating fibre detectors was studied with electrons at the spectrometer facility of the Mainz microtron MAMI, as well as in a C-12 beam of 2 AGeV energy and in a beam of different particle species at GSI. Multi-anode photomultipliers were used to read out one or more bundles of 128 fibres each in different geometries. For electrons a time resolution of FWHM = 1 ns was measured in a single detector plane with a detection efficiency epsilon > 99%. A time resolution of 310 ps (FWHM) between two planes of fibres was achieved for carbon ions, leading to a FWHM = 220 ps for a single detector. The hit position residual was measured with a width of FWHM = 0.27 mm. The var…
Silicon Detector Telescope for proton detection in electron scattering reactions at MAMI
Abstract A new Silicon Detector Telescope has been constructed and installed within the experimental facility of the A1 collaboration at Mainz Microtron, with the goal to detect low-energy protons. It consists of seven silicon layers for energy and angle measurement and a plastic scintillator for triggering purposes. The detector subtends a solid angle up to 88 msr, depending on the distance from the target and covers the proton kinetic energy range of 25–41 MeV with the mean energy resolution σ E = 0.47 MeV , operating at 500 kHz. Digital signal processing methods applied for energy reconstruction have been important for keeping the acceptable energy resolution at high counting rates. The…