0000000000266763

AUTHOR

Giuseppe Insalaco

0000-0002-9506-2233

Autonomic cardiac regulation in obstructive sleep apnea syndrome: evidence from spontaneous baroreflex analysis during sleep

Objective. To assess spontaneous baroreceptor-heart rate reflex sensitivity during sleep in patients with obstructive sleep apnea syndrome, a condition associated with increased cardiovascular morbidity and mortality and characterized by marked sympathetic activation, which is believed to originate from hypoxic chemoreceptor stimulation, although little is known of other possible mechanisms such as baroreflex impairment. Design and methods. In 11 patients with severe obstructive sleep apnea syndrome (mean ± SD age 46.8 ± 8.1 years, apnea/hypopnea index 67.9 ± 19.1 h), who were normotensive or borderline hypertensive during wakefulness by clinic blood pressure measurements, finger blood pres…

research product

Airway inflammation in nonasthmatic amateur runners

Elite athletes show a high prevalence of symptoms and signs of asthma, but no study has assessed the acute effects of endurance exercise on airway cells in nonasthmatic athletes. We measured exhaled nitric oxide (NO) and collected samples of induced sputum after 3% NaCl aerosol administration for 20 min in nonasthmatic middle-aged amateur runners after the Fourth Palermo International Marathon and 6–9 wk later (habitual training period) at baseline. After the marathon, exhaled NO ( n = 9 subjects) was higher [27 ± 9 parts/billion (ppb)] than at baseline (12 ± 4 ppb; P < 0.0005). Polymorphonuclear neutrophil (PMN) counts in induced sputum were much higher in runners (91.2 ± 3.6% of total…

research product

Circulating hematopoietic progenitor cells in runners

Because endurance exercise causes release of mediators and growth factors active on the bone marrow, we asked whether it might affect circulating hematopoietic progenitor cells (HPCs) in amateur runners [ n = 16, age: 41.8 ± 13.5 (SD) yr, training: 93.8 ± 31.8 km/wk] compared with sedentary controls ( n = 9, age: 39.4 ± 10.2 yr). HPCs, plasma cortisol, interleukin (IL)-6, granulocyte colony-stimulating factor (G-CSF), and the growth factor fms-like tyrosine kinase-3 (flt3)-ligand were measured at rest and after a marathon (M; n = 8) or half-marathon (HM; n = 8). Circulating HPC counts (i.e., CD34+cells and their subpopulations) were three- to fourfold higher in runners than in controls at b…

research product

Reticulocytes in untreated obstructive sleep apnoea.

Background and Aim. The short, repetitive hypoxaemic episodes observed in obstructive sleep apnoea (OSA) may determine small augmentations in mature red blood cells. It is unknown whether they affect reticulocyte release. This study explored whether the number and degree of maturation of circulating reticulocytes may be altered in OSA, possibly through the effect of erythropoietin. Methods. Fifty male adult patients with suspected OSA, normoxic during wakefulness, were studied. After nocturnal polysomnography, a blood sample was withdrawn for blood cells count, erythropoietin, iron and transferrin determination. Reticulocyte concentration and degree of immaturity [high (H), medium (M), or l…

research product

Perioperative Adverse Events in Obstructive Sleep Apnea and Use of Noninvasive Mechanical Ventilation: Key Topics and Clinical Implications

Obstructive sleep apnea (OSA) is a common public health care problem and, yet, the perioperative management of OSA remains inadequate. Patients affected by this condition are prone to early postoperative complications, in part due to the negative effects of sedative, analgesic, and anesthetic agents on pharyngeal tone and arousal responses to hypoxia, hypercapnia, and obstruction. The use of opioids may also contribute to late adverse events, mainly by suppressing the rapid eye movement phase of sleep. As a result, preoperative screening of patients at high risk of OSA, as well as the implementation of a perioperative strategy to reduce the risk of complications, should lead to early periop…

research product

Baroreflex control of heart rate during sleep in severe obstructive sleep apnoea: effects of acute CPAP

Baroreflex control of heart rate during sleep (baroreflex sensitivity; BRS) has been shown to be depressed in obstructive sleep apnoea (OSA), and improved after treatment with continuous positive airway pressure (CPAP). Whether CPAP also acutely affects BRS during sleep in uncomplicated severe OSA is still debatable. Blood pressure was monitored during nocturnal polysomnography in 18 patients at baseline and during first-time CPAP application. Spontaneous BRS was analysed by the sequence method, and estimated as the mean sequence slope. CPAP did not acutely affect mean blood pressure or heart rate but decreased cardiovascular variability during sleep. Mean BRS increased slightly during CPAP…

research product

Relaxin in Obstructive Sleep Apnea: Relationship with Blood Pressure and Inflammatory Mediators

<b><i>Background:</i></b> Obstructive sleep apnea (OSA) is associated with nocturnal intermittent hypoxia, which may be responsible for increased circulating levels of vascular endothelial growth factor (VEGF) and inflammatory mediators, such as metalloproteinases (MMPs), and which contributes to the pathogenesis of systemic hypertension. Why some OSA patients remain normotensive is poorly understood. Relaxin-2, a pregnancy hormone, may sometimes circulate in men and could increase in hypoxic conditions. It exerts a vasodilatory activity and can modulate the release of molecules, such as MMPs and VEGF. <b><i>Objectives:</i></b> The objective o…

research product

Blood pressure responsiveness to obstructive events during sleep after chronic CPAP

The aim of this study was to investigate whether chronic continuous positive airway pressure (CPAP) affects blood pressure (BP) responsiveness to obstructive events occurring on the first night of CPAP withdrawal in obstructive sleep apnoea (OSA) after chronic treatment. Thirteen male subjects with severe OSA underwent nocturnal polysomnography with beat­by­beat BP monitoring before treatment and after 4.9±3.4 months of home CPAP (mean daily use 5.1±1.7 h). Variations in oxyhaemoglobin saturation (Δ S a,O2), systolic (Δ P s), and diastolic (Δ P d) BP within nonrapid eye movement apnoeas and hypopnoeas were measured on a sample of pre­ and post­treatment events. In addition, a pretreatment s…

research product

Blood pressure changes after automatic and fixed CPAP in obstructive sleep apnea. Relationship with nocturnal sympathetic activity.

Treatment of obstructive sleep apnea (OSA) by continuous positive airway pressure (CPAP) usually causes a reduction in blood pressure (BP), but several factors may interfere with its effects. In addition, although a high sympathetic activity is considered a major contributor to increased BP in OSA, a relationship between changes in BP and in sympathetic nervous system activity after OSA treatment is uncertain. This study was undertaken to assess if, in OSA subjects under no pharmacologic treatment, treatment by CPAP applied at variable levels by an automatic device (APAP) may be followed by a BP reduction, and if that treatment is associated with parallel changes in BP and catecholamine exc…

research product