0000000000267151
AUTHOR
F.j. Egea
The GALILEO γ-ray array at the Legnaro National Laboratories
Abstract GALILEO, a new 4 π high-resolution γ -detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital read-out chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy γ -ray transitions. In this work, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.
A capacitor selector tool for on-board PDN designs in multigigabit applications
This paper presents a capacitor selector software tool for a proper on-board Power Distribution Network (PDN) design in those high-speed applications which have strict requirements on voltage noise up to the first hundreds of megahertz. Current commercial tools for PDN design only offer a manual choice of the capacitor value and their number simulating the board impedance profile. This manual resolution becomes very hard when the design has high power consumption and noise requirements are very strict. The aim of this software is to solve a basic on-board PDN design minimizing the number of "change simulate-analyze" iterations that have to be carried out in the manual PDN design. This softw…
Multiple register synchronization with a high-speed serial link using the Aurora protocol
In this work, the development and characterization of a multiple synchronous registers interface communicating with a high-speed serial link and using the Aurora protocol is presented. A detailed description of the developing process and the characterization methods and hardware test benches are also included. This interface will implement the slow control busses of the digitizer cards for the second generation of electronics for the Advanced GAmma Tracking Array (AGATA).
A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors
19th Real Time Conference (RT) -- MAY 26-30, 2014 -- Nara, JAPAN WOS: 000356458000028 This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected …
Pulse pile-up identification and reconstruction for liquid scintillator based neutron detectors
WOS: 000433206800010 The issue of pulse pile-up is frequently encountered in nuclear experiments involving high counting rates, which will distort the pulse shapes and the energy spectra. A digital method of off-line processing of pile-up pulses is presented. The pile-up pulses were firstly identified by detecting the downward-going zero-crossings in the first-order derivative of the original signal, and then the constituent pulses were reconstructed based on comparing the pile-up pulse with four models that are generated by combining pairs of neutron and.. standard pulses together with a controllable time interval. The accuracy of this method in resolving the pile-up events was investigate…
Performance of the Advanced GAmma Tracking Array at GANIL
The performance of the Advanced GAmma Tracking Array (AGATA) at GANIL is discussed, on the basis of the analysis of source and in-beam data taken with up to 30 segmented crystals. Data processing is described in detail. The performance of individual detectors are shown. The efficiency of the individual detectors as well as the efficiency after $\gamma$-ray tracking are discussed. Recent developments of $\gamma$-ray tracking are also presented. The experimentally achieved peak-to-total is compared with simulations showing the impact of back-scattered $\gamma$ rays on the peak-to-total in a $\gamma$-ray tracking array. An estimate of the achieved position resolution using the Doppler broadeni…
Graphical user interface for serial protocols through a USB link
In this work, a graphical user interface to communicate with three common serial protocols is presented. With one tool, the user may be able to control several evaluation boards from different manufacturers or evaluate and program integrated circuits of complex board prototypes. It provides a user-friendly interface to communicate with several chips using the USB port. The program has been used for the first stages in the qualification process of electronic boards for the Advanced GAmma Tracking Array (AGATA).
Development of the control card for the digitizers of the second generation electronics of AGATA
In this work, the features and development process of the novel control card for the digitizers of AGATA are presented. The board is part of the new hardware proposed for the electronic system of the experiment. In particular, the control card provides the sampling clock for the digitizers, contributes to the synchronization of the digital data and performs the slow control of its associated digitizer cards.
Test of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)
WOS: 000344994600012
Maximum Likelihood Estimation and non-linear least squares fitting with Levenberg-Marquardt Algorithm implementation in FPGA devices for high resolution hodoscopy
This work compares two possible solutions to achieve a higher resolution in a hodoscope based on Plastic Scintillating Fibers (PSF) by obtaining the point of maximum incidence of the radioactive beam. The two fitting algorithms proposed have been tested and implemented in Field Programmable Gate Array (FPGA) devices. On one hand, a probabilistic model based on the Maximum Likelihood Estimation (MLE) and on the other hand, non-linear least-squares fit with the Levenberg-Marquardt Algorithm (LMA).