0000000000269953
AUTHOR
Francisco J. Blanes-mompó
Medium-term visual, refractive, and intraocular stability after implantation of a posterior chamber phakic intraocular lens to correct moderate to high myopia.
To evaluate the medium-term refractive and visual outcomes and the complications after implantation of a silicone posterior chamber phakic intraocular lens (PC pIOL) for moderate to high myopia.Oftalmar, Medimar International Hospital, Alicante, Spain.Retrospective case series.Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, and intraocular pressure were evaluated during a medium-term follow-up. Postoperative complications were also studied.The study enrolled 35 eyes (mean preoperative spherical equivalent [SE] -10.25 diopters [D] ± 3.19 [SD]) of 20 patients with a mean age of 31.83 ± 8.87 years and a mean follow-up of 57.34 ± 9.24 months. The mean UDVA improved…
Fixed Mydriatic Pupil Associated with an Intraocular Pressure Rise as a Complication of the Implant of a Phakic Refractive Lens (PRL)
We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in o…
Preliminary in vivo positional analysis of a posterior chamber phakic intraocular lens by optical coherence tomography and its correlation with clinical outcomes
Purpose: To analyze by spectral-domain optical coherence tomography the anatomical relationship of a specific type of posterior chamber phakic intraocular lens (pIOL) implanted in cases of high to moderate myopia with the adjacent intraocular structures and to correlate it with clinical outcomes. Methods: Prospective observational case series including 18 eyes with high to moderate myopia (spherical equivalent between −5.88 and −15.75 D) of 9 patients (age range, 29–49 years) undergoing bilateral Phakic Refractive Lens (PRL, Zeiss) implantation. Postoperative visual acuity, refraction, contrast sensitivity (CS), and ocular higher order aberrations (HOA) were evaluated. Furthermore, the in v…
Clinical Impact of a Spontaneous Decentration of a Phakic Refractive Lens
PURPOSE To evaluate the clinical impact and possible causes of a spontaneous decentration of a phakic refractive lens (PRL) implanted in a highly myopic eye, and analyzing the visual, refractive, and aberrometric outcome as well as the possible causes for this phenomenon. METHODS The description of a case of bilateral high myopia corrected by implantation with the phakic intraocular lens (pIOL) PRL (Carl Zeiss Meditec, Germany) is presented and documented. Both eyes had similar anatomical configuration, and therefore, a pIOL (Model 101) with the same size was implanted without any associated intraoperative complication. Clinical outcomes were evaluated during a 3-month follow-up. RESULTS Im…