0000000000276500

AUTHOR

Federica Palorini

CP Violation in the SUSY Seesaw: Leptogenesis and Low Energy

We suppose that the baryon asymmetry is produced by thermal leptogenesis (with flavour effects), at temperatures $\sim 10^{9} - 10^{10}$ GeV, in the supersymmetric seesaw with universal and real soft terms. The parameter space is restricted by assuming that $l_\alpha \to l_\beta \gamma$ processes will be seen in upcoming experiments. We study the sensitivity of the baryon asymmetry to the phases of the lepton mixing matrix, and find that leptogenesis can work for any value of the phases. We also estimate the contribution to the electric dipole moment of the electron, arising from the seesaw, and find that it is (just) beyond the sensitivity of next generation experiments ($\lsim 10^{-29} e$…

research product

Insensitivity of leptogenesis with flavour effects to low energy leptonic CP violation

If the baryon asymmetry of the Universe is produced by leptogenesis, CP violation is required in the lepton sector. In the seesaw extension of the standard model with three hierarchical right-handed neutrinos, we show that the baryon asymmetry is insensitive to the Pontecorvo-Maki-Nagakawa-Sakata phases: thermal leptogenesis can work for any value of the observable phases. This result was well known when there were no flavor effects in leptogenesis; we show that it remains true when flavor effects are included.

research product

Adult exposures from MDCT including multiphase studies: first Italian nationwide survey.

To evaluate the radiation dose in routine multidetector computed tomography (MDCT) examinations in Italian population.This was a retrospective multicentre study included 5,668 patients from 65 radiology departments who had undergone common CT protocols: head, chest, abdomen, chest–abdomen–pelvis (CAP), spine and cardiac. Data included patient characteristics, CT parameters, volumetric CT dose index (CTDIvol) and dose length product (DLP) for each CT acquisition phase. Descriptive statistics were calculated, and a multi-regression analysis was used to outline the main factors affecting exposure.The 75th percentiles of CTDIvol (mGy) and DLP (mGy cm) for whole head were 69 mGy and 1,312 mGy cm…

research product

Radiation dose from multidetector CT studies in children: results from the first Italian nationwide survey

Background Multidetector CT (MDCT) scanners have con- tributed to the widespread use of CT in paediatric imaging. However, concerns are raised for the associated radiation exposure. Very few surveys on radiation exposure from MDCT studies in children are available. Objective The aim of this study was to outline the status of radiation exposure in children from MDCT practice in Italy. Materials and methods In this retrospective multicentre study we asked Italian radiology units with an MDCT scanner with at least 16 slices to provide dosimetric and acquisition param- eters of CT examinations in three age groups (1–5, 6–10, 11– 15 years) for studies of head, chest and abdomen. The dosi- metric…

research product