0000000000277564

AUTHOR

Mª Amparo Díez-ajenjo

Examining the utility of pinhole-type screens for lightfield display

The use of microlens arrays for lightfield display has the drawback of providing images with strong chromatic aliasing. To overcome this problem, pinhole-type lightfield monitors are proposed. This paper is devoted to evaluating the capability for such lightfield monitors to offer the user a convincing 3D experience with images with enough brightness and continuous aspect. Thus, we have designed a psychophysical test specifically adapted for lightfield monitors, which allowed us to confirm the usability of pinhole-type monitors.

research product

Lens Opacities in Valencia, Spain

Purpose. To evaluate the most common lens opacities in Valencia (Spain), analyzed by gender, grade, and type of cataracts. The results are compared with other studies performed at other geographical latitudes and on different races. Methods. A total of 1951 eyes of patients diagnosed with cataracts, aged between 30 and 96 years, were evaluated in accordance with age, gender, type and degree of the cataract, bilaterality and symmetry of this disease. Lens Opacities Classification System III was used to classify the cataract and the degree was graded as mild or moderate to advanced. Results. The most common type of cataract is corticonuclear in the elderly and subcapsular in younger subjects.…

research product

Blue-yellow deficiencies in young moderate smokers.

Purpose To evaluate whether tobacco affects color vision in young moderate smokers. Methods Chromatic mechanisms of 13 moderate smokers (10–20 cigarettes/day and at least 5 years smoking) and 17 non-smokers in the 18–35 age range were assessed with the Farnsworth-Munsell 100-hue (FM100h) test and short wavelength automated perimetry (SWAP). Results FM100h Total Error Scores (TES) were higher for smokers, and although differences were not significant (p = 0.14), a linear model with principal component analysis was able to explain 95% of the variance in TES and red-green partial error scores, though not in blue-yellow partial error scores (p = 0.07), using the number of years as smokers and t…

research product

Effect of the color of the intraocular lens on optical and visual quality

Purpose: To analyze the optical quality of intraocular lenses (IOL) with an orange (PC440Y) and a yellow (SN60AT) filter, and correlate these results with the visual quality of patients with these implants. Setting: Fisabio Oftalmología Médica, Valencia, Spain. Design: Randomized prospective study. Materials and Methods: The IOL optical quality was determined using the modulation transfer function (MTF) and the spectral transmission. The visual quality of 87 eyes with cataract (51 with orange filter and 36 with yellow filter) was determined by best corrected visual acuity (BCVA) and contrast sensitivity function (CSF) under photopic and mesopic conditions. To analyze the results, we use a S…

research product