0000000000278070

AUTHOR

Isil Cekic-nagas

Light transmittance of zirconia as a function of thickness and microhardness of resin cements under different thicknesses of zirconia

Objective: The objective of this study was to compare microhardness of resin cements under different thicknesses of zirconia and the light transmittance of zirconia as a function of thickness. Study design: A total of 126 disc-shaped specimens (2 mm in height and 5 mm in diameter) were prepared from dual-cured resin cements (RelyX Unicem, Panavia F and Clearfil SA cement). Photoactivation was performed by using quartz tungsten halogen and light emitting diode light curing units under different thicknesses of zirconia. Then the specimens (n=7/per group) were stored in dry conditions in total dark at 37°C for 24 h. The Vicker's hardness test was performed on the resin cement layer with a micr…

research product

The cytotoxicity of resin composites cured with three light curing units at different curing distances.

Objective: The purpose of this study was to compare the effect of light curing distance on the cytotoxicity of five resin composites cured with three high-power light curing units. Study design: Seven cylindrical discs of each material (Grandio ®, Voco; Filtek ? Z250, 3M ESPE; Clearfil ? AP-X, Kuraray Co. Ltd.; Aelite ? LS, Bisco Inc. and Simile ®, Pentron) were cured. For curing, soft-up mode of quartz-tungsten-halogen, exponential mode of light emitting diode for 20 s, and ramp-curing mode of plasma arc light curing units for 6 s were used. The curing tip distances were determined as 2 and 9 mm and controlled via the use of metal rings. After ageing the samples for 24 and 72 hours in Dulb…

research product

The effect of light curing units and modes on cytotoxicity of resin-core systems

Objective: The aim of this study was to compare the cytotoxic effects of various resin-based core materials that were cured with three light curing units (LCUs) in different modes on L?929 mouse fibroblast cells over 24 h and 72 h periods. Study design: Eighty-four cylindrical discs (2 mm in thickness and 6 mm in diameter) of each material (Rebilda, Voco; Build-It FR, Pentron; Clearfil DC Core, Kuraray and Bis-core, Bisco) were cured by QTH LCU (soft-up and high-power modes), LED LCU (exponential and standard modes) and PAC LCU (normal and ramp-curing modes). Then the samples were aged for 24 and 72 hours in Dulbecco?s Modified Eagle Medium/Ham?s F12 (DMEM/F12). After each ageing interval, …

research product

Biomechanical behavior of cavity configuration on micropush-out test: A finite-element-study

Objective: The objective of this study was to simulate the micropush-out bond strength test from a biomechanical point of view. For this purpose, stress analysis using finite element (FE) method was performed. Study design: Three different occlusal cavity shapes were simulated in disc specimens (model A: 1.5 mm cervical, 2 mm occlusal diameter; model B: 1.5 mm cervical, 1.75 mm occlusal diameter; model C: 1.5 mm cervical, 1.5 mm occlusal diameter). Quarter sizes of 3D FE specimen models of 4.0×4.0×1.25 mm3 were constructed. In order to avoid quantitative differences in the stress value in the models, models were derived from a single mapping mesh pattern that generated 47.182 elements and 6…

research product