0000000000281007

AUTHOR

P. Goldoni

INTEGRAL and RXTE observations of accreting millisecond pulsar IGR J00291+5934 in outburst

Simultaneous observations of the accretion-powered millisecond pulsar IGR J00291+5934 by International Gamma-Ray Astrophysics Laboratory and Rossi X-ray Timing Explorer during the 2004 December outburst are analysed. The average spectrum is well described by thermal Comptonization with an electron temperature of 50 keV and Thomson optical depth tau_T ~ 1 in a slab geometry. The spectral shape is almost constant during the outburst. We detect a spin-up of the pulsar with nudot=8.4x10E-13 Hz/s. The ISGRI data reveal the pulsation of X-rays at a period of 1.67 milliseconds up to ~150 keV. The pulsed fraction is shown to increase from 6 per cent at 6 keV to 12--20 per cent at 100 keV. This is n…

research product

First observations of the X-ray transient EXO 2030+375 with IBIS/ISGRI

We present a first INTEGRAL observation of the 42s transient X-ray pulsar EXO 2030+375 with IBIS/ISGRI. The source was detected during Cyg X-1 observations in December 2002. We analyzed observations during the outburst period from 9 to 21 December 2002 with a total exposure time of ~770 kiloseconds. EXO 2030+375 was almost always detected during single ~30 minute exposures in the 18-45 energy bands. The source light curve shows the characteristic outburst shape observed in this source.

research product

High-Energy pulse profile of the Transient X-ray Pulsar SAX J2103.5+4545

In two recent INTEGRAL papers, Lutovinov et al. (2003) and Blay et al. (2004) report a timing and spectral analysis of the transient Be/X-ray pulsar SAX J2103.5+4545 at high energies (5--200 keV). In this work we present for the first time a study of the pulse profile at energies above 20 keV using INTEGRAL data. The spin-pulse profile shows a prominent (with a duty cycle of 14%) and broad (with a FWHM of ~ 51 s) peak and a secondary peak which becomes more evident above 20 keV. The pulsed fraction increases with energy from ~ 45% at 5--40 keV to ~ 80% at 40--80 keV. The morphology of the pulse profile also changes as a function of energy, consistent with variations in the spectral componen…

research product

INTEGRAL monitoring of the Black Hole candidate 1E 1740.7-2942

The brightest persistent Galactic black hole candidate close to the Galactic Centre, 1E 1740.7-2942, has long been observed with INTEGRAL. In this paper, we report on the long-term hard X-ray monitoring obtained during the first year of observations as part of the Galactic Centre Deep Exposure. We discuss the temporal and spectral behaviours in different energy bands up to 250 keV, as well as the hardness-flux correlations.

research product

Sensitivity of the Cherenkov Telescope Array for probing cosmology and fundamental physics with gamma-ray propagation

Full list of authors: Abdalla, H.; Abe, H.; Acero, F.; Acharyya, A.; Adam, R.; Agudo, I; Aguirre-Santaella, A.; Alfaro, R.; Alfaro, J.; Alispach, C.; Aloisio, R.; Batista, R. Alves; Amati, L.; Amato, E.; Ambrosi, G.; Anguner, E. O.; Araudo, A.; Armstrong, T.; Arqueros, F.; Arrabito, L.; Asano, K.; Ascasibar, Y.; Ashley, M.; Backes, M.; Balazs, C.; Balbo, M.; Balmaverde, B.; Baquero Larriva, A.; Martins, V. Barbosa; Barkov, M.; Baroncelli, L.; de Almeida, U. Barres; Barrio, J. A.; Batista, P-, I; Becerra Gonzalez, J.; Becherini, Y.; Beck, G.; Tjus, J. Becker; Belmont, R.; Benbow, W.; Bernardini, E.; Berti, A.; Berton, M.; Bertucci, B.; Beshley, V; Bi, B.; Biasuzzi, B.; Biland, A.; Bissaldi, …

research product

A Hard X-Ray View of Scorpius X-1 with INTEGRAL : Nonthermal Emission?

We present here simultaneous INTEGRAL/RXTE observations of Sco X-1, and in particular a study of the hard X-ray emission of the source and its correlation with the position in the Z-track of the X-ray color-color diagram. We find that the hard X-ray (above about 30 keV) emission of Sco X-1 is dominated by a power-law component with a photon index of ~3. The flux in the power-law component slightly decreases when the source moves in the color-color diagram in the sense of increasing inferred mass accretion rate from the horizontal branch to the normal branch/flaring branch vertex. It becomes not significantly detectable in the flaring branch, where its flux has decreased by about an order of…

research product

Sensitivity of the Cherenkov Telescope Array to a dark matter signal from the Galactic centre

Full list of authors: Acharyya, A.; Adam, R.; Adams, C.; Agudo, I.; Aguirre-Santaella, A.; Alfaro, R.; Alfaro, J.; Alispach, C.; Aloisio, R.; Alves Batista, R.; Amati, L.; Ambrosi, G.; Angüner, E. O.; Antonelli, L. A.; Aramo, C.; Araudo, A.; Armstrong, T.; Arqueros, F.; Asano, K.; Ascasíbar, Y. Ashley, M.; Balazs, C.; Ballester, O.; Baquero Larriva, A.; Barbosa Martins, V.; Barkov, M.; Barres de Almeida, U.; Barrio, J. A.; Bastieri, D.; Becerra, J.; Beck, G.; Becker Tjus, J.; Benbow, W.; Benito, M.; Berge, D.; Bernardini, E.; Bernlöhr, K.; Berti, A.; Bertucci, B.; Beshley, V.; Biasuzzi, B.; Biland, A.; Bissaldi, E.; Biteau, J.; Blanch, O.; Blazek, J.; Bocchino, F.; Boisson, C.; Bonneau Arbe…

research product

The Multi-frequency Robotic facility REM: first results

The REM Observatory, recently installed and commissioned at la Silla Observatory Chile, is the first moderate aperture robotic telescope able to cover simultaneously the visible-NIR (0.45-2.3 microns) wavelength range. Due to its very fast pointing and its full robotization REM is conceived for fast transients observation. The high throughput Infrared Camera (REMIR) and the Visible imaging spectrograph (ROSS), simultaneously fed by a dichroic, allow to collect high S/N data in an unprecedented large spectral range on a telescope of this size. The REMobservatory is an example of a versatile and agile facility necessary complement to large telescopes in fields in which rapid response and/or t…

research product

GRB 050904 at redshift 6.3: observations of the oldest cosmic explosion after the Big Bang

We present optical and near-infrared observations of the afterglow of the gamma-ray burst GRB 050904. We derive a photometric redshift z = 6.3, estimated from the presence of the Lyman break falling between the I and J filters. This is by far the most distant GRB known to date. Its isotropic-equivalent energy is 3.4x10^53 erg in the rest-frame 110-1100 keV energy band. Despite the high redshift, both the prompt and the afterglow emission are not peculiar with respect to other GRBs. We find a break in the J-band light curve at t_b = 2.6 +- 1.0 d (observer frame). If we assume this is the jet break, we derive a beaming-corrected energy E_gamma = (4-12)x10^51 erg. This limit shows that GRB 050…

research product

The INTEGRAL IBIS/ISGRI System Point Spread Function and Source Location Accuracy

The imager on board INTEGRAL (IBIS) presently provides the most detailed sky images ever obtained at energies above 30 keV. The telescope is based on a coded aperture imaging system which allows to obtain sky images in a large field of view 29deg x 29deg with an angular resolution of 12'. The System Point Spread Function of the telescope and its detailed characteristics are here described along with the specific analysis algorithms used to derive the accurate point-like source locations. The derived location accuracy is studied using the first in-flight calibration data on strong sources for the IBIS/ISGRI system. The dependence of the calibrated location accuracy with the signal to noise r…

research product

INTEGRAL serendipitous detection of the gamma-ray microquasar LS 5039

LS 5039 is the only X-ray binary persistently detected at TeV energies by the Cherenkov HESS telescope. It is moreover a gamma-ray emitter in the GeV and possibly MeV energy ranges. To understand important aspects of jet physics, like the magnetic field content or particle acceleration, and emission processes, such as synchrotron and inverse Compton (IC), a complete modeling of the multiwavelength data is necessary. LS 5039 has been detected along almost all the electromagnetic spectrum thanks to several radio, infrared, optical and soft X-ray detections. However, hard X-ray detections above 20 keV have been so far elusive and/or doubtful, partly due to source confusion for the poor spatial…

research product