Microbial environmental contamination in Italian dental clinics: A multicenter study yielding recommendations for standardized sampling methods and threshold values.
A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWS…
Epidemiology of intensive care unit-acquired sepsis in Italy: Results of the SPIN-UTI network
Background. Sepsis is the major cause of mortality from any infectious disease worldwide. Sepsis may be the result of a healthcare associated infection (HAI): the most frequent adverse events during care delivery especially in Intensive Care Units (ICUs). The main aim of the present study was to describe the epidemiology of ICU-acquired sepsis and related outcomes among patients enrolled in the framework of the Italian Nosocomial Infections Surveillance in ICUs - SPIN-UTI project. Study design. Prospective multicenter study. Methods. The SPIN-UTI network adopted the European protocols for patient-based HAI surveillance. Results. During the five editions of the SPIN-UTI project, from 2008 to…
Network SPIN-UTI: valutazione degli aspetti organizzativi ed operativi del ProgettoSPIN
Italian multicenter study on infection hazards during dental practice: Control of environmental microbial contamination in public dental surgeries
Abstract Background The present study assessed microbial contamination in Italian dental surgeries. Methods An evaluation of water, air and surface microbial contamination in 102 dental units was carried out in eight Italian cities. Results The findings showed water microbial contamination in all the dental surgeries; the proportion of water samples with microbial levels above those recommended decreased during working. With regard to Legionella spp., the proportion of positive samples was 33.3%. During work activity, the index of microbial air contamination (IMA) increased. The level of microbial accumulation on examined surfaces did not change over time. Conclusion These findings confirm …