0000000000297452

AUTHOR

Denise Kämpfner

Reduction of ICD Shock Burden by Eliminating Back-Up Pacing Induced Ventricular Tachyarrhythmias

ICD Shock Reduction by Subthreshold Pacing Introduction Implantable cardioverter defibrillators (ICD) may have the capacity to provoke or worsen ventricular tachyarrhythmias (VT). It has been reported that ICD shocks by itself can increase mortality. This study aimed to determine the role of back-up pacing-induced VT (PIT) in the overall ICD shock burden by avoiding pause-related ventricular back-up pacing. Methods and Results A population of 550 single-chamber ICD patients was studied. Of them, 17 (3%, 69 ± 16 years, 14 male) patients had documented episodes of PIT. A total of 431 VT episodes were documented including 89 (21%) due to PIT. In 3 patients, VT events were exclusively PITs. Aft…

research product

The Incidence of Audible Steam Pops Is Increased and Unpredictable With the ThermoCool® Surround Flow Catheter During Left Atrial Catheter Ablation: A Prospective Observational Study

Audible Steam Pops During Left Atrial Catheter AblationIntroduction Open irrigated radiofrequency (RF) ablation catheters with a porous tip (56 holes, TC-SF) permit delivering RF energy in a temperature-controlled mode without temperature rise. This prospective observational study investigated the association of different catheter parameters on the occurrence of audible steam pops during left atrial (LA) ablation. Methods and Results A total of 226 patients underwent TC-SF catheter ablation for atrial fibrillation. RF power delivery, impedance and catheter tip temperature were continually recorded throughout the ablation. Pulmonary vein isolation was performed with a maximum of 27 W and LA …

research product

Arrhythmia Termination Versus Elimination of Dormant Pulmonary Vein Conduction as a Procedural End Point of Catheter Ablation for Paroxysmal Atrial Fibrillation: A Prospective Randomized Trial.

Background— Pulmonary vein isolation (PVI) is still associated with a substantial number of arrhythmia recurrences in paroxysmal atrial fibrillation (AF). This prospective, randomized study aimed to compare 2 different procedural strategies. Methods and Results— A total of 152 patients undergoing de novo ablation for paroxysmal AF were randomized to 2 different treatment arms. The procedure in group A consisted of PVI exclusively. In this group, all isolated PVs were challenged with adenosine to reveal and ablate dormant conduction. In group B, PVI was performed with the patient either in spontaneous or in induced AF. If AF did not terminate with PVI, ablation was continued by targeting ex…

research product