0000000000300743

AUTHOR

J. Szerypo

showing 40 related works from this author

High-accuracy mass determination of unstable cesium and barium isotopes

1999

Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of $\delta \mbox{m} \approx 13$ keV have been obtained. The masses of $^{123,124,126}$Ba and $^{122m}$Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.

PhysicsNuclear and High Energy PhysicsIsotope[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]010308 nuclear & particles physicschemistry.chemical_element[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryPenning trap7. Clean energy01 natural sciencesISOLTRAPAtomic massNuclear physicsMasschemistryCaesium0103 physical sciencesNuclear Physics - ExperimentAtomic physicsNuclear Experiment010306 general physicsHybrid mass spectrometer
researchProduct

Direct mass measurements of neutron-rich zirconium isotopes up toZr104

2004

Atomic masses of radioactive zirconium isotopes from {sup 96}Zr to {sup 104}Zr have been measured with a relative accuracy of {<=}5x10{sup -7} using a Penning trap coupled to the ion guide isotope separator on-line system. The obtained two-neutron separation energies show strong local correlation in relation to the shape change and shape coexistence between N=58 and 60.

PhysicsNuclear and High Energy PhysicsIsotopeNuclear structureAnalytical chemistryMass spectrometryPenning trapAtomic massIonNuclear physicsIsotopes of zirconiumNeutronPhysics::Atomic PhysicsNuclear ExperimentPhysical Review C
researchProduct

Erratum to: “Mass measurements on neutron-deficient Sr and neutron-rich Sn isotopes with the ISOLTRAP mass spectrometer” [Nucl. Phys. A 763 (2005) 45]

2006

Nuclear physicsPhysicsNuclear and High Energy PhysicsIsotope0103 physical sciencesNeutron010306 general physicsMass spectrometry010303 astronomy & astrophysics01 natural sciencesISOLTRAPNuclear Physics A
researchProduct

High-accuracy mass determination of neutron-rich rubidium and strontiumiIsotopes

2002

The penning-trap mass spectrometer ISOLTRAP, installed at the on-line isotope separator ISOLDE at CERN, has been used to measure atomic masses of $^{88,89,90m,91,92,93,94}$Rb and $^{91- 95}$Sr. Using a resolving power of R $\!\scriptstyle\approx$1 million a mass accuracy of typically 10 keV was achieved for all nuclides. Discrepancies with older data are analyzed and discussed, leading to corrections to those data. Together with the present ISOLTRAP data these corrected data have been used in the general mass adjustment.

PhysicsNuclear and High Energy PhysicsIsotope010308 nuclear & particles physics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryPenning trap01 natural sciencesISOLTRAPAtomic massNuclear physics0103 physical sciencesMass spectrumNeutronNuclear Physics - ExperimentNuclideAtomic physics010306 general physics
researchProduct

A linear radiofrequency quadrupole ion trap for the cooling and bunching of radioactive ion beams

2000

A linear radiofrequency quadrupole ion guide and beam buncher has been installed at the ISOLTRAP mass spectrometry experiment at the ISOLDE facility at CERN. The apparatus is being used as a beam cooling, accumulation, and bunching system. It operates with a buffer gas that cools the injected ions and converts the quasicontinuous 60- keV beam from the ISOLDE facility to 2.5-keV beam pulses with improved normalized transverse emittance. Recent measurements suggest a capture efficiency of the ion guide of up to 40% and a cooling and bunching efficiency of at least 12% which is expected to still be increased. The improved ISOLTRAP setup has so far been used very successfully in three on-line e…

PhysicsNuclear and High Energy PhysicsIon beam010308 nuclear & particles physics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Ion gunAccelerators and Storage Rings01 natural sciences7. Clean energyISOLTRAPNuclear physicsIon beam deposition0103 physical sciencesPhysics::Accelerator PhysicsIon trapAtomic physicsQuadrupole ion trapBeam emittanceNuclear Experiment010306 general physicsBeam (structure)Nuclear Physics A
researchProduct

First mass measurement at JYFLTRAP

2004

The first mass measurements at JYFLTRAP facility are reviewed. Those are also first ever direct mass measurements of the heaviest Zr-isotopes. Results are compared to atomic mass evaluation data and the recent calculations. The first TOF-resonances from high-precision trap and an implication to high-precision mass measurements are discussed.

Trap (computing)PhysicsNuclear physicsNuclear and High Energy PhysicsEvaluation dataAtomic physicsNuclear ExperimentMass measurementAtomic massNuclear Physics A
researchProduct

Direct mass measurements of neutron-deficient xenon isotopes with the ISOLTRAP mass spectrometer

2000

Abstract The masses of Xe isotopes with 124⩾ A ⩾114 have been measured using the ISOLTRAP spectrometer at the on-line mass separator ISOLDE/CERN. A mass resolving power of 500 000 was chosen resulting in an accuracy of δm ≈12 keV for all isotopes investigated. Conflicts with existing mass data of several standard deviations were found.

PhysicsNuclear and High Energy PhysicsSpectrometer[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]Physics::Instrumentation and Detectors010308 nuclear & particles physics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometry01 natural sciencesISOLTRAPAtomic massIsotopes of oxygenNuclear physics0103 physical sciencesIsotopes of xenonAtomic physicsParticle PhysicsNuclear Experiment010306 general physicsQuadrupole mass analyzerHybrid mass spectrometer
researchProduct

Quadrupole excitation of stored ion motion at the true cyclotron frequency

1995

Abstract The motion of an ion in a Penning trap has been investigated in the presence of an azimuthal quadrupole radio frequency field and a damping force provided by buffer gas collisions. Analytical expressions are derived which describe the line shape of the cyclotron resonance as well as the properties of the mass-selective cooling mechanism for heavy ions. Excellent agreement is observed between theoretical results and experimental data obtained with the tandem Penning trap mass spectromer ISOLTRAP at ISOLDE (CERN).

ChemistryCyclotron resonancePhysics::Atomic PhysicsIon trapAtomic physicsQuadrupole ion trapNuclear ExperimentPenning trapQuadrupole mass analyzerISOLTRAPSpectroscopyFourier transform ion cyclotron resonanceIon cyclotron resonanceInternational Journal of Mass Spectrometry and Ion Processes
researchProduct

A linear radiofrequency ion trap for accumulation, bunching, and emittance improvement of radioactive ion beams

2000

An ion beam cooler and buncher has been developed for the manipulation of radioactive ion beams. The gas-filled linear radiofrequency ion trap system is installed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Its purpose is toaccumulate the 60-keV continuous ISOLDE ion beam with high efficiency and to convert it into low-energy low-emittance ion pulses. The efficiency was found to exceed 10\,\% in agreement with simulations. A more than 10-fold reduction of the ISOLDE beam emittance can be achieved. The system has been used successfully for first on-line experiments. Its principle, setup and performance will be discussed. An ion beam cooler and buncher has been developed fo…

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsIon beamIon trapFOS: Physical sciencesMass spectrometryIon cooling01 natural sciencesISOLTRAPIonNuclear physics0103 physical sciencesThermal emittance[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Nuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentInstrumentationNuclear ExperimentRadioactive ion beamsIon guide21.10.Dr; 2.10.Bi; 07.75.+hPhysicsOn-line mass spectrometry010308 nuclear & particles physicsInstrumentation and Detectors (physics.ins-det)Penning trapAccelerators and Storage RingsIon buncherPhysics::Accelerator PhysicsIon trapBeam emittance
researchProduct

Preparation of targets for the gas-filled recoil separator TASCA by electrochemical deposition and design of the TASCA target wheel assembly

2008

Abstract The Transactinide Separator and Chemistry Apparatus (TASCA) is a recoil separator with maximized transmission designed for performing advanced chemical studies as well as nuclear reaction and structure investigations of the transactinide elements ( Z >103) on a one-atom-at-a-time basis. TASCA will provide a very clean transactinide fraction with negligible contamination of lighter elements from nuclear side reactions in the target. For TASCA a new target chamber was designed and built at GSI including the rotating target wheel assembly ARTESIA for beam intensities up to 2 μA (particle). For the production of longer-lived isotopes of neutron-rich heavier actinide and transactinide e…

LanthanidePhysicsNuclear and High Energy PhysicsCuriumAnalytical chemistrychemistry.chemical_elementThoriumTransactinide elementActinideUraniumPlutoniumchemistryNuclear fusionInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A cylindrical Penning trap for capture, mass selective cooling, and bunching of radioactive ion beams

1997

Abstract A Penning trap ion accumulator, cooler, and buncher for low-energy ion beams has been developed for the ISOLTRAP mass spectrometer at ISOLDE/CERN. A cylindrical electrode configuration is used for the creation of a nested trapping potential. This is required for efficient accumulation of externally produced ions and for high-mass selectivity by buffer gas cooling. The design goal of a mass resolving power of about 1 × 10 5 has been achieved. Isobar separation has been demonstrated for radioactive rare-earth ion beams delivered by the ISOLDE on-line mass separator.

Nuclear and High Energy PhysicsIon beamChemistryMass spectrometryPenning trapIon gunISOLTRAPIon sourceNuclear physicsSecondary ion mass spectrometryPhysics::Accelerator PhysicsIon trapDetectors and Experimental TechniquesAtomic physicsNuclear ExperimentInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Studying exotic nuclides close to the N = Z line at the HIGISOL facility

2003

The ion guide [1, 2] for heavy-ion fusion-evaporation reactions (HIGISOL) which was developed by Beraud et al. [3] has been implemented at the IGISOL facility in Jyvaskyla [4]. This system was modified over the past 5 years. Figure 1 shows the present set-up. The HIGISOL takes advantage of the different angular distributions of primary beam and reaction products: the primary beam is stopped in front of the stopping chamber and the reaction products enter the stopping chamber through a thin foil passing the beam stop. This so called “shadow” method removes the plasma effect since the primary beam is not ionising the stopping gas. In order to improve ion optical properties, mainly to reduce t…

PhysicsNuclear physicsDc voltageIon beamPlasma effectSkimmer (machine)NuclideBeam (structure)Line (formation)Ion
researchProduct

A radio frequency ring electrode cooler for low-energy ion beams

2004

We are investigating a new concept for ion confinement while buffer-gas-cooling low-energy ion beams. Instead of applying the well-established technique of Radio Frequency Quadrupoles (RFQs) where the ions are transversely confined by a quadratic-pseudo potential we are using a stack of thin ring electrodes supplied by an RF field (RF funnel) which creates a box-shaped potential well. In Monte Carlo simulations we have investigated the transmission behavior and cooling performance of the RF funnel. First experimental investigations with ion currents up to 20 nA revealed a promising transmission characteristic which qualifies the RF funnel as high-current cooler.

PhysicsNuclear and High Energy Physicsbusiness.product_categorybusiness.industryMonte Carlo methodRing (chemistry)IonNuclear magnetic resonanceTransmission (telecommunications)Stack (abstract data type)ElectrodeOptoelectronicsFunnelRadio frequencybusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Medium-spin structure of neutron-rich Pd and Cd isotopes

2003

Cadmium isotopes are traditionally considered as good examples of nearly spherical, vibrational nuclei, which can be described by quadrupole vibrators in the collective model, as well as the U(5) dynamical symmetry in the interacting boson model (IBM). However, the shape coexistence of more deformed intruder states originating from proton 2p–4h excitation across the Z = 50 major shell is another interesting structural aspect, whose presence in Pd-isotopes has also been demonstrated [1,2].

PhysicsProtonIsotopes of cadmiumQuadrupoleShell (structure)NeutronInteracting boson modelSpin structureAtomic physicsNuclear ExperimentExcitation
researchProduct

Breakdown of the Isobaric Multiplet Mass Equation atA=33,T=3/2

2001

Mass measurements on ${}^{33,34,42,43}\mathrm{Ar}$ were performed using the Penning trap mass spectrometer ISOLTRAP and a newly constructed linear Paul trap. This arrangement allowed us, for the first time, to extend Penning trap mass measurements to nuclides with half-lives below one second ( ${}^{33}\mathrm{Ar}$: ${T}_{1/2}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}174\mathrm{ms}$). A mass accuracy of about ${10}^{\ensuremath{-}7}$ $(\ensuremath{\delta}m\ensuremath{\approx}4\mathrm{keV})$ was achieved for all investigated nuclides. The isobaric multiplet mass equation was checked for the $A\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}33$, $T\phantom{\rule{0ex}{0ex}}=\phantom…

Mass formulaPhysicsMass numberGeneral Physics and AstronomyIsobaric processIon trapAtomic physicsQuadratic form (statistics)Penning trapISOLTRAPMultipletPhysical Review Letters
researchProduct

Fine structure of the Gamow-Teller resonance revealed in the decay of150Ho2−isomer

2003

The $\ensuremath{\gamma}$ rays following the $72s$ ${}^{150}\mathrm{Ho}$ ${2}^{\ensuremath{-}}$ Gamow-Teller $\ensuremath{\beta}$ decay have been investigated with the CLUSTER CUBE setup, an array of six EUROBALL CLUSTER Ge detectors in close cubic geometry, providing a $\ensuremath{\gamma}$ ray detection sensitivity of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}5}$ per $\ensuremath{\beta}$-parent decay for $\ensuremath{\gamma}$-ray energies up to 5 MeV. The fine structure of the Gamow-Teller resonance at 4.4-MeV excitation in ${}^{150}\mathrm{Dy}$ has been studied. The resolved levels are compared with Shell Model predictions.

PhysicsNuclear and High Energy PhysicsAstrophysics::High Energy Astrophysical PhenomenaNuclear TheorySHELL modelStructure (category theory)ResonanceSensitivity (control systems)Atomic physicsNuclear ExperimentExcitationPhysical Review C
researchProduct

Penning-trap mass measurements of neutron-deficient Rb and Sr isotopes

1993

Abstract The Penning-trap mass spectrometer ISOLTRAP installed at the on-line mass separator ISOLDE 2 at CERN has been used for mass determination of 75–87 Rb and 78–83,87 Sr. Ions are captured in a Penning trap and their cyclotron frequency ω c = ( q m )B in the trapping field B is measured. Ratios of these frequencies lead to the determination of the atomic mass of these isotopes. A resolving power of typically m Δm = 10 6 and an accuracy of δm ≈10 keV is obtained. The mass of 78 Sr is measured for the first time and, in most cases, the mass values of the other isotopes are significantly improved. The experimental masses are compared with theoretical predictions.

PhysicsNuclear and High Energy Physics010308 nuclear & particles physics[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]Isotopes of chlorine[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Penning trapMass spectrometry7. Clean energy01 natural sciencesISOLTRAPIsotopes of oxygenAtomic massNuclear physicsMass0103 physical sciencesNuclear Physics - ExperimentAtomic physics010306 general physicsQuadrupole mass analyzer
researchProduct

Accurate masses of neutron-deficient nuclides close to

2001

Abstract Mass measurements with the Penning-trap mass spectrometer ISOLTRAP at ISOLDE/CERN are extended to nonsurface ionizable species using newly developed ion-beam bunching devices. Masses of 179–197Hg, 196,198Pb, 197Bi, 198Po and 203At were determined with an accuracy of 1×10 −7 corresponding to δm≈20  keV. Applying a resolving power of up to 3.7×10 6 ground and isomeric states of 185,187,191,193,197Hg were separated. First experimental values for the isomeric excitation energy of 187,191Hg are obtained. A least-squares adjustment has been performed and theoretical approaches are discussed to model the observed fine structure in the binding energy.

PhysicsNuclear and High Energy PhysicsBinding energyNeutronNuclideAtomic physicsMass spectrometryPenning trapISOLTRAPAtomic massExcitationNuclear Physics A
researchProduct

βdecay of neutron-rich118Agand120Agisotopes

2003

$\ensuremath{\beta}$ decays of on-line mass-separated neutron-rich ${}^{118}\mathrm{Ag}$ and ${}^{120}\mathrm{Ag}$ isotopes have been studied by using $\ensuremath{\beta}\ensuremath{-}\ensuremath{\gamma}$ and $\ensuremath{\gamma}\ensuremath{-}\ensuremath{\gamma}$ coincidence spectroscopy. Extended decay schemes to the ${}^{118,120}\mathrm{Cd}$ daughter nuclei have been constructed. The three-phonon quintuplet in ${}^{118}\mathrm{Cd}$ is completed by including a new level at 2023.0 keV, which is tentatively assigned the spin and parity of ${2}_{4}^{+}.$ The intruder band in ${}^{118}\mathrm{Cd}$ is proposed up to the ${4}^{+}$ level at 2322.4 keV. The measured $\ensuremath{\beta}$-decay half…

PhysicsNuclear and High Energy PhysicsProtonIsotopeQuadrupoleNeutronAtomic physicsSpin (physics)Physical Review C
researchProduct

Radiative capture of protons by the deformed nuclide232Th

1986

The excitation function for the radiative capture232Th(p, γ)233Pa has been determined in the proton energy range 7 to 20 MeV by an activation method. The results are compared with a compound nucleus model prediction and earlier experimental data for another deformed nuclide176Yb. As in previous cases an enhancement over the CN-model prediction is observed and the excitation of the giant dipole resonance via the direct-semidirect reaction process is a likely explanation. Supplementary measurements of the232Th (p, f) excitation function in the proton energy range 11–20 MeV have been performed.

PhysicsExcitation functionNuclear and High Energy PhysicsRange (particle radiation)ResonanceDipolemedicine.anatomical_structureRadiative transfermedicineNuclear fusionAtomic physicsNuclear ExperimentNucleusExcitationZeitschrift f�r Physik A Atomic Nuclei
researchProduct

Excited states inPd115populated in theβ−decay ofRh115

2010

Excited states in $^{115}\mathrm{Pd}$, populated following the ${\ensuremath{\beta}}^{\ensuremath{-}}$ decay of $^{115}\mathrm{Rh}$ have been studied by means of $\ensuremath{\gamma}$ spectroscopy after the Penning-trap station at the IGISOL facility, University of Jyv\"askyl\"a. The $1$$/$$2$${}^{+}$ spin and parity assignment of the ground state of $^{115}\mathrm{Pd}$, confirmed in this work, may indicate a transition to an oblate shape in Pd isotopes at high neutron number.

PhysicsBaryonNuclear and High Energy PhysicsIsotopes of palladiumDouble beta decayExcited stateHadronAtomic physicsNuclear ExperimentNucleonGround stateRadioactive decayPhysical Review C
researchProduct

Towards Shorter-Lived Nuclides in ISOLTRAP Mass Measurements

2001

Recently, the applicability of Penning trap mass spectrometry has been extended to nuclides with a half-life of less than one second. The mass of 33Ar(T 1/2 = 174 ms) was measured using the ISOLTRAP spectrometer with an accuracy of 4.2 keV. This measurement provided a stringent test of the Isobaric Multiplet Mass Equation (IMME) at mass number A = 33 and isospin T = 3/2. The fast measurement cycle that shows the way to other measurements of very-short-lived nuclides is presented. Furthermore, the results of the IMME test are displayed.

Nuclear physicsMass numberChemistryNuclideIon trapAtomic physicsMass spectrometryPenning trapISOLTRAPAtomic massHybrid mass spectrometer
researchProduct

Extension of Penning-trap mass measurements to very short-lived nuclides

2000

Abstract Mass measurements on 33,34,42,43 Ar have been performed at the ISOLTRAP spectrometer. An accuracy of δm ≈4 keV has been achieved for all measured isotopes. With 33 Ar it is the first time that a nuclide with a half-life shorter than one second has been investigated using a Penning trap. This became possible due to the recently installed linear radio-frequency ion-trap system and an improved, faster measurement cycle.

PhysicsNuclear and High Energy PhysicsSpectrometerIsotope010308 nuclear & particles physics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Penning trap7. Clean energy01 natural sciencesISOLTRAPAtomic massNuclear physics13. Climate action0103 physical sciencesNuclear Physics - ExperimentIon trapNuclideAtomic physics010306 general physicsHybrid mass spectrometerNuclear Physics A
researchProduct

Decay study ofTc114with a Penning trap

2011

The level structure of $^{114}\mathrm{Ru}$ has been investigated via the $\ensuremath{\beta}$ decay of very neutron-rich $^{114}\mathrm{Tc}$ by means of Penning-trap-assisted $\ensuremath{\gamma}$ spectroscopy. The deduced $\ensuremath{\beta}$-decay scheme suggests the existence of two $\ensuremath{\beta}$-decaying states in $^{114}\mathrm{Tc}$ with ${I}^{\ensuremath{\pi}}={1}^{+}$ and $I\ensuremath{\geqslant}$ 4, with half-lives of ${t}_{1/2}({1}^{+})=90(20)$ ms and ${t}_{1/2}(I\ensuremath{\geqslant}4)=100(20)$ ms, respectively. The ${Q}_{\ensuremath{\beta}}$ value, which covers a possible mixture of two states, has been determined to be ${Q}_{\ensuremath{\beta}}=11 785(12)$ keV. The level…

PhysicsBaryonNuclear and High Energy Physicssymbols.namesakeQ valueHadronsymbolsElementary particleFermionAtomic physicsNucleonHamiltonian (quantum mechanics)Radioactive decayPhysical Review C
researchProduct

Status of HIGISOL a new version equipped with SPIG and electric field guidance

2001

A new HIGISOL chamber devoted to the study of short-lived products from heavy-ion-induced fusion-evaporation reactions is proposed. It enables, via the extraction of ions by means of a SPIG (SextuPole rf Ion Guide), to improve the mass resolving power by a factor 2.5 compared to the previous system using a skimmer-ring assembly. The gas cell was also equiped with an electric field for faster transportation of recoiling ions to the nozzle where they are ejected with the gas jet. The first results obtained both with a radioactive α-source and cyclotron beam will be reported.

Jet (fluid)Field (physics)[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]ChemistryNuclear engineeringNozzleCyclotron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energy030218 nuclear medicine & medical imagingIonlaw.inventionNuclear physics03 medical and health sciences0302 clinical medicinePhysics::Plasma PhysicslawElectric field0103 physical sciencesNuclear spectroscopy010306 general physicsBeam (structure)
researchProduct

Direct mass measurements of unstable rare earth isotopes with the ISOLTRAP mass spectrometer

1996

Abstract Direct mass measurements of neutron deficient rare earth isotopes in the vicinity of 146 Gd were performed for the first time with the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Since ISOL-facilities deliver these isotopes with a large amount of isobaric contamination, these measurements became possible only after the installation of a new cooler trap which acts as an isobar separator. To date more than 40 isotopes of the elements Pr, Nd, Pm, Sm, Eu, Dy, and Ho have been measured with a typical accuracy of δm ≈ 14 keV. Some of these isotopes provide an important anchor for many other isotopes linked by known Q-values.

PhysicsNuclear and High Energy PhysicsIsotope010308 nuclear & particles physicsIsotopes of argon[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryPenning trap01 natural sciences7. Clean energyISOLTRAPIsotopes of oxygenIsotopes of nitrogenNuclear physics13. Climate action0103 physical sciencesNeutronAtomic physics010306 general physicsNuclear Physics A
researchProduct

Gamow-Teller decay of 118Pd and of the new isotope 120Pd

1993

Abstract With the use of the proton-induced fission of 238 U and the ion guide-fed on-line mass separation, even- A isotopes of palladium with high neutron excess were studied by means of γ-ray and conversion-electron spectroscopy. The decay of 118 Pd was reinvestigated in detail, and evidence for the new isotope 120 Pd, with a half-life T 1 2 = 0.5 ± 0.1 s , was found. As established for 118 Pd and tentatively shown for 120 Pd, the β-decay of these two isotopes proceeds mainly through 0 + → 1 + Gamow-Teller transitions with log ft values between 4.2 and 4.7. The strength of individual transitions has been compared with the predictions of the shell-correction model with a deformed Woods-Sax…

PhysicsNuclear and High Energy PhysicsDecay schemeIsotope010308 nuclear & particles physicsFissionchemistry.chemical_element01 natural sciences7. Clean energyIonchemistryPairing0103 physical sciencesNeutronAtomic physics010306 general physicsSpectroscopyPalladiumNuclear Physics A
researchProduct

New levels in 118Pd observed in the beta-decay of very neutron-rich 118Rh isotope

2006

We investigate the β decay of very neutron-rich 118Rh isotope using on-line mass-separated sources which are produced by applying 25 MeV proton induced symmetric fission of natural uranium at the IGISOL facility. The β–γ and γ–γ coincidence spectroscopy is employed to establish the level scheme of daughter nucleus 118Pd. Five low-lying new levels are identified for the first time with tentative spin and parity assignments based on the even-mass Pd systematics.

PhysicsIsotopeFissionNuclear TheoryGeneral Physics and AstronomyNatural uraniumBeta decayCoincidenceNuclear physicsmedicine.anatomical_structuremedicineNeutronNuclear ExperimentSpectroscopyNucleus
researchProduct

Beta decay of the new isotope101Sn

1995

The very neutron-deficient isotope 101Sn was produced in a 50Cr(58Ni, 2p5n) reaction and its decay properties were determined for the first time. By using chemically selective ion sources of an on-line mass separator, the energy spectrum and the half-life (3 ± 1 s) of beta-delayed protons of 101Sn were measured. These results are compared to theoretical predictions.

PhysicsDecay schemeIsotopeSeparator (oil production)Condensed Matter PhysicsBeta decayAtomic and Molecular Physics and OpticsBeta-decay stable isobarsIonNuclear physicsEnergy spectrumAtomic physicsNuclear ExperimentMathematical PhysicsPhysica Scripta
researchProduct

Isomeric state of 80Y and its role in the rp-process

2003

The HIGISOL facility has been used to investigate carefully the isomeric transition 228.5 keV in 80Y. We have measured the electron internal conversion coefficient for this transition αK = 0.50 ± 0.07 which gives the value for half-life of “bare” isomeric state T 1/2 = 6.8 ± 0.5 s. The isomeric state should play an important role in the rp-process calculations.

Materials scienceThermodynamicsElectronState (functional analysis)rp-processNuclear isomerInternal conversion coefficientValue (mathematics)
researchProduct

Penning trap for isobaric mass separation at IGISOL

2003

Abstract A cylindrical Penning trap has been built at the ion guide isotope separator facility IGISOL of the University of Jyvaskyla. The main goal of the Penning trap application is to purify low-energy radioactive ion beams. The aim is to make isobarically pure beams. The technical description is presented.

Radioactive ion beamsNuclear and High Energy PhysicsIsotopeChemistrySeparator (oil production)Penning trapMass separationIonNuclear physicsPhysics::Accelerator PhysicsIsobaric processPhysics::Atomic PhysicsIon trapAtomic physicsNuclear ExperimentInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

First Precision Mass Measurements of Refractory Fission Fragments

2005

Atomic masses of 95-100Sr, 98-105Zr, and [corrected] 102-110Mo and have been measured with a precision of 10 keV employing a Penning trap setup at the IGISOL facility. Masses of 104,105Zr and 109,110Mo are measured for the first time. Our improved results indicate significant deviations from the previously published values deduced from beta end point measurements. The most neutron-rich studied isotopes are found to be significantly less bound (1 MeV) compared to the 2003 atomic mass evaluation. A strong correlation between nuclear deformation and the binding energy is observed in the two-neutron separation energy in all studied isotope chains.

PhysicsIsotopeFissionBeta (plasma physics)Binding energyGeneral Physics and AstronomyPhysics::Atomic PhysicsAtomic physicsDeformation (meteorology)Nuclear ExperimentPenning trapMass spectrometryAtomic massPhysical Review Letters
researchProduct

JYFLTRAP: a Penning trap for precision mass spectroscopy and isobaric purification

2012

In this article a comprehensive description and performance of the double Penning-trap setup JYFLTRAP will be detailed. The setup is designed for atomic mass measurements of both radioactive and stable ions and additionally serves as a very high-resolution mass separator. The setup is coupled to the IGISOL facility at the accelerator laboratory of the University of Jyväskylä. The trap has been online since 2003 and it was shut down in the summer of 2010 for relocation to the upgraded IGISOL facility. Numerous atomic mass and decay energy measurements have been performed using the time-of-flight ion-cyclotron resonance technique. The trap has also been used in several decay spectroscopy expe…

Physicsnuclear spectroscopyNuclear and High Energy Physicsaccelerator-based physicsCyclotronPenning trapMass spectrometrykiihdytinpohjainen fysiikkaAtomic massIonlaw.inventionNuclear physicsydinrakenneDecay energylawnuclear structureydinspektroskopiaNuclear fusionPhysics::Atomic PhysicsSpectroscopyNuclear Experimentydinfysiikka
researchProduct

Mass measurements on unstable Sn and Sr isotopes with the ISOLTRAP mass spectrometer

2001

Direct mass measurements have been performed on the isotopes 76,77,80,81Sr and 129,130,131,132Sn by means of the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. In the case of 76Sr the mass was measured for the first time and an accuracy of about 30 keV was reached (Fig. 1). The masses of the tin isotopes are known for a long time from Q β measurements.

PhysicsLarge Hadron ColliderIsotope[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex][PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Penning trapMass spectrometry01 natural sciencesISOLTRAP010305 fluids & plasmasNuclear physics0103 physical sciencesIsotopes of tin010306 general physics
researchProduct

JYFLTRAP: a cylindrical Penning trap for isobaric beam purification at IGISOL

2004

Abstract A Penning trap has been installed for isobaric beam purification at the IGISOL-facility at the University of Jyvaskyla. In this paper, the technical details of this new device together with results of the first tests are presented. The mass resolving power, depending on the excitation parameters and the ion species, can be as high as 145 000 and the total transmission has been determined to be 17%. In addition, it is shown that with this experimental setup it is possible to measure atomic masses up to A=120 with accuracies of approximately 50 keV .

PhysicsNuclear and High Energy PhysicsTotal transmissionIsobaric processNew deviceAtomic physicsNuclear ExperimentPenning trapInstrumentationExcitationBeam (structure)Atomic massIonNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Penning trap at IGISOL

2002

The IGISOL facility [1] at the Department of Physics of the University of Jyvaskyla (JYFL) is delivering radioactive beams of short-lived exotic nuclei, in particular the neutron-rich isotopes from fission reaction. These nuclei are studied with the nuclear and collinear laser spectroscopy methods. In order to obtain a meaningful increase, in comparison to a standard level, of precision and sensitivity of such studies an improvement of the radioactive beam quality is necessary. This improvement will be achieved due to a radioactive beam handling which consists of three steps: beam cooling, bunching and (isobaric) purification. The latter means a possibility of obtaining a pure monoisotopic …

PhysicsNuclear and High Energy PhysicsIsotopeNuclear TheoryPenning trapIonNuclear physicsNuclear fissionPhysics::Accelerator PhysicsIsobaric processNuclear Physics - ExperimentMonoisotopic massAtomic physicsNuclear ExperimentSpectroscopyBeam (structure)
researchProduct

A new pulsed release method for element selective production of neutron rich isotopes near 208Pb

1998

Abstract A new method to reduce the isobaric contamination problem for the production of neutron rich Bi, Pb and Tl nuclei at on-line mass separators, based on the pulsed release of these radioactive species, is presented. The results of a feasibility study are reported.

Nuclear and High Energy PhysicsIsotopeChemistryRadiochemistryIsobaric processNeutronContaminationInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Isomeric state of $^{80}$Y and its role in the astrophysical rp-process

2001

5 pages, 7 figures.-- PACS nrs: 21.10.Tg; 23.20.Nx; 27.50.+e.

59 ≤ A ≤ 89 [[PACS] Properties of specific nuclei listed by mass ranges]PhysicsNuclear and High Energy Physics[PACS] Properties of specific nuclei listed by mass ranges: 59 ≤ A ≤ 89Proton[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]010308 nuclear & particles physicsHadronElectron[PACS] Internal conversion and extranuclear effects (including Auger electrons and internal bremsstrahlung)rp-processNuclear isomer[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyNuclear physicsExcited state0103 physical sciences[PACS] Lifetimes widthsAtomic physics010306 general physicsInternal conversion coefficientExcitation
researchProduct

Towards higher accuracy with the ISOLTRAP mass spectrometer

1996

To now the masses of more than hundred unstable isotopes have been determined with the ISOLTRAP mass spectrometer installed at ISOLDE/CERN. Typically a resolving power of mΔm ≈ 1 × 106 was used and the mass determinations were assigned an accuracy of δmm ≈ 1 × 10−7. We show that with improvements to ISOLTRAP and refinements of the experimental technique an accuracy of δmm ≈ 3 × 10−8 can be obtained.

Nuclear and High Energy PhysicsLarge Hadron ColliderIsotope010308 nuclear & particles physicsChemistry[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex][PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Penning trapMass spectrometry01 natural sciencesISOLTRAPAtomic massNuclear physics0103 physical sciencesAtomic physics010306 general physicsInstrumentation
researchProduct

Mass measurements on neutron-deficient Sr and neutron-rich Sn isotopes with the ISOLTRAP mass spectrometer

2005

Abstract The atomic masses of 76,77,80,81,86,88 Sr and 124,129,130,131,132 Sn were measured by means of the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. 76 Sr is now the heaviest N = Z nucleus for which the mass is measured to a precision better than 35 keV. For the tin isotopes in the close vicinity of the doubly magic nucleus 132 Sn, mass uncertainties below 20 keV were achieved. An atomic mass evaluation was carried out taking other experimental mass values into account by performing a least-squares adjustment. Some discrepancies between older experimental values and the ones reported here emerged and were resolved. The results of the new adjustment and their impact will be pr…

PhysicsNuclear and High Energy Physicsatomic masses010308 nuclear & particles physics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryISOLTRAP01 natural sciencesISOLTRAPAtomic massNuclear physicsMasstin0103 physical sciencesIsotopes of tinNeutronstrontiumAtomic physics010306 general physicsNuclear ExperimentQuadrupole mass analyzerhigh-precision mass spectrometryHybrid mass spectrometer07.75.+h 21.10.Dr 32.10.Bi
researchProduct