0000000000306533

AUTHOR

Francesca Pugliese

Coronary plaque imaging with multislice computed tomography: technique and clinical applications.

The composition of an atherosclerotic lesion, rather than solely the degree of stenosis, is considered to be an important determinant of acute coronary events. Whereas until recently only invasive techniques have been able to provide clues about plaque composition with consistent reproducibility, several recent studies have revealed the potential of multislice computed tomography (MSCT) for noninvasive plaque imaging. Coronary MSCT has the potential to detect coronary plaques and to characterize their composition based on the X-ray attenuating features of each structure. MSCT may also reveal the total plaque burden (calcified and noncalcified components) for individual patients with coronar…

research product

Non-invasive visualisation of coronary atherosclerosis: state-of-art.

Coronary artery disease remains the leading cause of death in the Western world. Non-invasive coronary artery imaging challenges any diagnostic modality because the coronary arteries are small and tortuous, whereas cardiac contraction and respiration cause motion artifacts. Therefore, non-invasive coronary imaging requires high spatial and temporal resolution. This review discusses the feasible applications in coronary imaging of magnetic resonance imaging and multi-slice computed tomography (MSCT), which are currently the only non-invasive diagnostic modalities for direct coronary atherosclerosis imaging. Particular attention and focus is devoted to the potential indications and clinical i…

research product

Diagnostic accuracy of 64-slice CT in the assessment of coronary stents

PURPOSE: The purpose of this study was to assess the diagnostic accuracy of 64-slice computed tomography (64-CT) coronary angiography in the detection of coronary in-stent restenosis. MATERIALS AND METHODS: Ninety-five patients (72 men and 23 women, mean age 58+/-8 years) with previous percutaneous coronary intervention with stenting and suspected restenosis underwent 64-CT (Sensation 64, Siemens). The mean time between stent deployment and 64-CT was 6.1+/-4.2 months. The scan parameters were: slices 32 x 2, individual detector width 0.6 mm, rotation time 0.33 s, feed 3.84 mm/rotation, 120 kV, 900 mAs. After the intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml,…

research product

Imaging techniques for the vulnerable coronary plaque

The goal of this article is to illustrate the main invasive and noninvasive diagnostic modalities to image the vulnerable coronary plaque, which is responsible for acute coronary syndrome. The main epidemiologic and histological issues are briefly discussed in order to provide an adequate background. Comprehensive coronary atherosclerosis imaging should involve visualization of the entire coronary artery tree and plaque characterization, including three-dimensional morphology, relationship with the lumen, composition, vascular remodelling and presence of inflammation. No single technique provides such a comprehensive description, and no available modality extensively identifies the vulnerab…

research product

Parameters for coronary plaque vulnerability assessed with multidetector computed tomography and intracoronary ultrasound correlation

In the absence of a fixed relationship between plaque vulnerability and flow-limiting stenosis, alternative morphological expressions exist that could predict the liability of coronary lesions to rapidly progress or rupture, causing acute coronary syndromes. Modern multidetector computed tomography technology is capable of noninvasively detecting lesion location, attenuation, remodeling and calcification pattern, which may be considered as surrogate morphological markers of vulnerability and could contribute to increase the prognostic value of individual coronary plaque burden. J Cardiovasc Med 10:821 -826 (C) 2009 Italian Federation of Cardiology.

research product

Prevalence of anatomical variants and coronary anomalies in 543 consecutive patients studied with 64-slice CT coronary angiography

The aim of our study was to assess the prevalence of variants and anomalies of the coronary artery tree in patients who underwent 64-slice computed tomography coronary angiography (CT-CA) for suspected or known coronary artery disease. A total of 543 patients (389 male, mean age 60.5 +/- 10.9) were reviewed for coronary artery variants and anomalies including post-processing tools. The majority of segments were identified according to the American Heart Association scheme. The coronary dominance pattern results were: right, 86.6%; left, 9.2%; balanced, 4.2%. The left main coronary artery had a mean length of 112 +/- 55 mm. The intermediate branch was present in the 21.9%. A variable number …

research product

Assessment of left main coronary artery atherosclerotic burden using 64-slice CT coronary angiography: correlation between dimensions and presence of plaques.

PURPOSE: The aim of this study was to correlate left main (LM) coronary artery dimensions with the presence of atherosclerosis by multidetector-row computed tomography (MDCT) coronary angiography (CA) and to assess coronary atherosclerotic plaques with a semiquantitative method. MATERIALS AND METHODS: Sixty-two consecutive patients (41 men, mean age 60+/-11) with suspected coronary artery disease underwent 64-MDCT coronary angiography. LM dimensions (length, ostial and bifurcation diameters), quantitative [location, Hounsfield unit (HU) attenuation] and qualitative (composition, shape) analysis of plaques within the LM were performed. All patients underwent conventional CA. RESULTS: Thirty …

research product

Ischemic Heart Disease, CT

research product

High Iodine Concentration Contrast Material for Noninvasive Multislice Computed Tomography Coronary Angiography

OBJECTIVE: The objective of this study was to compare intracoronary attenuation on 16-row multislice computed tomography (16-MSCT) coronary angiography using 2 contrast materials (CM) with high iodine concentration. MATERIAL AND METHODS: Forty consecutive patients (29 male, 11 female; mean age, 61 ± 11 years) with suspected coronary artery disease were randomized to 2 groups to receive 100 mL of either iopromide 370 (group 1: Ultravist 370, 370 mg iodine/mL; Schering AG, Berlin, Germany) or iomeprol 400 (group 2: Iomeron 400, 400 mg iodine/mL; Bracco Imaging SpA, Milan, Italy). Both CM were administered at a rate of 4 mL/s. All patients underwent 16-MSCT coronary angiography (Sensation 16; …

research product