0000000000321066
AUTHOR
R. Catherall
Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy
A high-voltage divider with accuracy at the ppm level and collinear laser spectroscopy were used to calibrate the highvoltage installation at the radioactive ion beam facility ISOLDE at CERN. The accurate knowledge of this voltage is particularly important for collinear laser spectroscopy measurements. Beam velocity measurements using frequencycomb based collinear laser spectroscopy agree with the new calibration. Applying this, one obtains consistent results for isotope shifts of stable magnesium isotopes measured using collinear spectroscopy and laser spectroscopy on laser-cooled ions in a trap. The long-term stability and the transient behavior during recovery from a voltage dropout were…
Measurement of the 7Be(n,p) cross section at thermal energy
The 7Be(n,p) cross section was measured with an ion-implanted 7Be target at a thermal neutron beam of the research reactor LVR-15 in Řež. The cross section to the ground state of 7Li is σ(n,p0)=43800±1400b and the cross section to the first excited state of 7Li is σ(n,p1)=520±260b.
Quadrupole and octupole collectivity in the semi-magic nucleus 80,206Hg126
The first low-energy Coulomb-excitation measurement of the radioactive, semi-magic, two proton-hole nucleus 206Hg, was performed at CERN’s recently-commissioned HIE-ISOLDE facility. Two γ rays depopulating low-lying states in 206Hg were observed. From the data, a reduced transition strength B(E2; 2+ 1 → 0+ 1 ) = 4.4(6) W.u was determined, the first such value for an N = 126 nucleus south of 208Pb, which is found to be slightly lower than that predicted by shell-model calculations. In addition, a collective octupole state was identified at an excitation energy of 2705 keV, for which a reduced B(E3) transition probability of 30+10−13 W.u was extracted. These results are crucial for understand…
The laser ion source trap for highest isobaric selectivity in online exotic isotope production
The improvement in the performance of a conventional laser ion source in the laser ion source and trap (LIST) project is presented, which envisages installation of a repeller electrode and a linear Paul trap/ion guide structure. This approach promises highest isobaric purity and optimum temporal and spatial control of the radioactive ion beam produced at an online isotope separator facility. The functionality of the LIST was explored at the offline test separators of University of Mainz (UMz) and ISOLDE/CERN, using the UMz solid state laser system. Ionization efficiency and selectivity as well as time structure and transversal emittance of the produced ion beam was determined. Next step aft…